• Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
  • Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
  • Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
  • Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
  • Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
  • Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator

Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator

After-sales Service: Warranty Certificate
Warranty: 1 Year
Frequency Range: 3-15Hz
Type: Pulse Signal Generator
Channel: 1
Display: Digital
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Features
  • Product Parameters
Overview

Basic Info.

Model NO.
XHHV535-4T
Voltage
0-35kv Customized for 40kv
High Voltage Divider
Voltage Accuracy Level 1.5
Discharge Power
2450j
Transport Package
Exported Wooden Case
Specification
534*444*805 mm
Trademark
XZH TEST
Origin
China
Production Capacity
2000PCS/Year

Product Description

Product Description

XHHV535-4T  35KV High voltage pulse generator

This device integrates DC high voltage source, energy storage capacitor, discharge ball device, automatic discharge device, and a cart-type high-end experimental instrument. The equipment completely solves the problems of convenience, portability, safety and reliability of traditional experimental devices.

This instrument uses high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, making the whole machine simple in structure. In order to retain people's original habit of using transformers and operating boxes to generate DC high voltage, this pulse generator adopts a humanized design operation mode and integrates a micro-reliable circuit design. It is safe, reliable and intuitive. Really achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and pressure resistance. It is currently the most user-friendly trolley-type DC impact high-voltage equipment.
Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator

Features

 

High-voltage pulse output is uniform and controllable;
With double 1.5-level pointer meter display of current and voltage, it is intuitive and clear, and the impact discharge process is clear at a glance;
High-voltage side voltage measurement, real-time and accurate;
With zero start protection function, safe and reliable;
Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device;
The discharge time can be selected in two modes: timing and manual;
With DC withstand voltage function;
Internally installed high-precision test cable fault sampling waveform module;
Humanized design trolley, easy to move.
 


Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator

 

 

Product Parameters

 

Voltage Range: 0-35kV
High voltage divider: Voltage Accuracy 1.5 grade
Inside capacitor : 4uf
Surge time: Auto surge about 5s, also can control by hands.
Discharge energy: 2450J
Surge power: 2KVA
Impact time 1-10 second  manual
Weight:  about 119kg(4uF)
Power supply:  AC 220V + 10% 50Hz/±2Hz (other frequency can be customized)
Environment temperature:  -20 ~ +50 ºC
 

 

Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
Composition of equipment
1. High voltage pulse generator host: apply high voltage, high energy pulse signal to the cable under test;

2. High voltage output line: Connect the high voltage output end of the host to the measured cable core;

3. Ground wire: high voltage ground, safety, sampling ground and discharge rod ground wire;

4. Double Q line: host communication base and cable fault tester connection line;

5. Power cord: instrument working power cord;

6. Sampler: When high-voltage flashover method, receive high-voltage signal reflected to the sampling ground signal;

7. Discharge rod: DC limited discharge or DC short circuit discharge at the end of the cable under test.

8. Safety pipe: 220VAC power supply system backup safety pipe;


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Panel introduction
Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator



1, Ammeter (Ammeter) : low voltage side of the current size indication.

2, Voltmeter: high voltage output voltage indication kV meter, divided into 8kV, 16kV, 32kV combined voltage level switch reading.

3, high voltage lamp (HV) : on indicates a high voltage output, off indicates no high voltage output. Power: After the power switch is turned on, the indicator is on, indicating that the AC220V is normal.

4. Power light: After turning on the power switch, the indicator is on, indicating that AC220V is normal.

5, Zero light (Zero) : indicates that the pressure regulator is in the zero state, and only when it lights up the start key is effective.

6, communication base (Signal) : Connect the machine and cable fault tester with double Q line flashover acquisition waveform, only effective when high-voltage flashover.

7, power socket (AC220V) : instrument working power supply, 220VAC connection port;

8. Safety tube seat: 220VAC power supply system safety tube installation place;

9, power switch (NO/OFF) : "I" use AC220V power supply to power the system, "0" shut down.

10, Single key (Single) : when the mode selection key in the single function, this key is effective.

11, Mode selete: divided into voltage (DC), Single (Single), Cycle (Cycle) three modes. DC is the voltage resistance function. When this function is selected, the voltage resistance test is carried out for the cable. Single is a manual function. When this function is selected, the voltage will be boosted after the high voltage starts. Press the Single key to manually trigger the impulse discharge. Cycle is an automatic function. When this function is selected, the high voltage is started at this time to boost the voltage, and the instrument will automatically trigger the impulse discharge for about 5 seconds.

12, Start key (Start) : in the zero state, press the start key, at this time the high voltage start, high voltage light. In the non-zero state, the start high voltage lamp does not light.

13, Stop key (Stop) : when the test is completed or abnormal, press this key to cut off the high voltage output, and the remaining high voltage of the test will be automatically discharged at this time.

14, Voltage control: This knob in the zero state, zero light, high voltage can be started. Only after the high pressure is started can the pressure be increased through the pressure regulator.


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Application: 0-35kV underground cable fault location
Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator

We have another model XHHV535-4TS with voltage level 8/16/32kV, discharge energy 0-2048J under each voltage level. Welcome you contact us for more information and service.



-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Packing & Shipping
 

Packaging: Wooden case filled with foam 

Shipping: by Air, Sea, Express, etc.

Shipping time: 7-15 days if it's in stock. 
Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge GeneratorXzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
Xzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge GeneratorXzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge GeneratorXzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge GeneratorXzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge GeneratorXzh 535-4t 35kv 2450j High Voltage Pulse Generator Cable Thumper Underground Cable Fault Locating Surge Generator
 







 

 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now