• Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
  • Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
  • Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
  • Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
  • Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
  • Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

After-sales Service: Warranty Certificate
Warranty: 1 Year
Transport Package: Wooden Case
Specification: 475*345*205mm
Trademark: XZH TEST
Origin: China Xi′an
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XHGG502
HS Code
9031809090
Production Capacity
2000pieces /Year

Product Description

 

Product Introduction

The XHGG502 ARC underground cable fault locator is suitable for measuring the low resistance, short circuit, open circuit and disconnection faults of various materials of different cross-sections and different media, high-frequency coaxial cables, local telephone cables, street light cables, and buried wires. Prevent leakage and high-resistance flashover faults. Super powerful cable management system, automatic report generation.
 
Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator
Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator


 
Main features
1. It can detect the high and low resistance faults of all cables of 35KV and below, and it has a wide range of applications.
2. The instrument adopts the latest technology of embedded industrial computer and the most advanced "eight pulse method" in the world.
It got impact high-pressure flashover method and low-pressure pulse method.
3. Any high-impedance fault presents the simplest waveform characteristics similar to a low-voltage pulse short-circuit fault, which is very easy to interpret.
4. With user-friendly software, full English menu and screen touch button operation. The button definition is simple and clear. The measurement method is simple and fast.
5. The success rate of failure detection, test accuracy and test convenience are better than any domestic testing equipment.
6. Ultra-high brightness, large LCD screen as the display terminal, can be clearly observed in the environment of direct sunlight
Screen waveform. The instrument has powerful data processing capabilities and a friendly display interface.
7. With the function of handwriting board, when the waveform is stored, the personnel, locations and fault characteristics of the field test can be stored.
Information such as the test process is directly handwritten into the saved document.
8. With extremely safe high-voltage protection measures. The flash tester will not crash or be damaged in an impact high-pressure environment.
9. Has a standard printer USB interface.
10. Simple operation and high reliability. Has a very high cost performance.
11. No test blind zone.
12. Built-in polymer lithium battery power supply, can test cable open circuit and low resistance short circuit fault in no power environment.




Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

Technical data


 
Display
12-inch industrial-grade computer control, touch operation mode;
system  XP operating system, super cable management system, automatically generate test report;
Functions distance measurement and speed measurement;
Data sampling rate 60MHz, 120 MHz, 240MHz, 400MHz;
Automatic Fully automatic continuous sampling, never miss any discharge waveform;
Test method low-voltage pulse method, high-voltage flashover method, multiple pulse method
Pulse width 0.1uS and 2uS
Pulse amplitude 400Vpp
Measuring distance >60Km
Reading resolution  0.1m
 
Test accuracy less than 0.5m
Pulse coupler withstand voltage 38kVDC
The reflected signal sent by the pulse coupler is automatically displayed, and the full-length waveform of the open circuit of the cable is displayed at the same time. This makes the representation of the fault characteristic waveform extremely simple. There is only one type of high-resistance fault waveform, that is, the short-circuit fault waveform similar to the low-voltage pulse method.

The fault distance is automatically displayed and there is no test blind zone.


With the function of storing massive test waveforms: The waveforms tested on site can be conveniently stored in the instrument in a prescribed order for recall and observation at any time.

The measured fault point waveform and the good-phase full-length open-circuit waveform can be displayed on the screen at the same time for comparison on the same screen and superimposed comparison. Makes the judgment of the fault distance more accurate.

Built-in polymer lithium battery power supply: it can work continuously for more than 4 hours after being fully charged. Fully meet the requirements of on-site testing. It can also work with an external AC power supply.

Eight pulse transmission and fault reflection signals are automatically displayed, and the full-length waveform of the cable open circuit is displayed at the same time. This makes the representation of the fault characteristic waveform extremely simple. There is only one type of high-resistance fault waveform, that is, the short-circuit fault waveform similar to the low-voltage pulse method. The fault distance is automatically displayed and there is no test blind zone.


Working conditions: temperature -25ºC~+55ºC, relative humidity 85%, atmospheric pressure 750±30mmHg.



----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; roughly test cable fault distance

 


Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(single-shot/ multi-shot).
 
Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator



There are three test mode of XHGG502, low voltage pulse, high voltage flashover, ARC multi-shot.
--------------------------------------------------------------------------------------------------------------------------------------------------------


The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502.
Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

--------------------------------------------------------------------------------------------------------------------------------------------------------

The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502

Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

--------------------------------------------------------------------------------------------------------------------------------------------------------

The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.

Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator


---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
 



Welcome you contact us for more information
Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

Our team


Xzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre LocatorXzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre LocatorXzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre LocatorXzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre LocatorXzh Test Multiple Pulse Arc Underground Cable Fault Locator Tdr Cable Fault Pre Locator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.