Customization: | Available |
---|---|
After-sales Service: | Warranty |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description
The cable fault tester adopts an industrial-grade 10.1-inch touch-integrated computer, a simple operating software interface, industrial-grade integrated circuits and devices, and a built-in large-capacity lithium-ion battery, which is stable, reliable, and easy to use.
This cable fault tester is a special instrument for measuring and analyzing the status and fault distance of power cables. This cable fault tester uses a combination of modern electronic technology and computer technology to achieve signal filtering, acquisition, data processing, graphic display, and graphic analysis. Cable speed measurement, cable length test, cable fault distance test.
This cable fault tester is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Network failure. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites", "DL/T 849.1-2019 General technical conditions for special testers for power equipment Part 1: Cable fault flash tester", "JJF1042-2020" "Calibration Specifications for Cable Fault Testers" standard requirements.
Work mode: TDR(low voltage pulse), High voltage flashover( ICE(Impulse current)/Decay)
Features
• 10.1-inch full-color TFT touch display;
• Embedded system, safe, stable and simple display and operation mode;
• With the function of testing cable wave speed, cable length and fault distance;
• Fully automatic continuous sampling, waveform capture at all times, timely and accurate.
• Equipped with automatic test range setting, automatic waveform analysis and display of test distance.
• Full English menu, two operation methods of touch and coded buttons, simple, fast and reliable.
• Equipped with testing technology of low-voltage pulse method, high-voltage flashover method, the waveform display is smooth and easy to interpret.
• The instrument has powerful data processing capabilities, making it convenient for users to manage and archive waveform files.
• Has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument in the order specified by Chinese naming for recall and observation at any time; it can store more than 8,000 records of low-voltage pulses and high-voltage flashover waveforms, and multiple pulses More than 250 waveform records can be recorded, and waveform files can be imported into computer software for management and analysis using USB communication.
• Ultra-high brightness, LED backlight brightness reaches 280nit, resolution 1024*600, convenient for environments exposed to direct sunlight in operation.
Technical specification
Sampling frequency | 80MHz |
Low voltage pulse amplitude | 100V±15% |
Ranging range | ≥65km |
Test range | 300m/1km/5km/25km/65km |
Pulse width | 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS |
Minimum resolution | 0.1m |
Test blind area | ≤20m |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
Power supply mode | charging AC110V~240V, 50Hz/60Hz |
Volume and weight | L358mm×W284mm×H168mm-4.7kg |
Working conditions | Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg |
Packing list
Introduction
Cable fault locator XHDD503B uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.
Technical indicators
Acoustic-magnetic synchronous fixed-point function |
||
Acoustic-magnetic synchronous fixed-point function |
Sound channel | a) Bandwidth All pass: 100Hz~1500Hz. Low pass: 100Hz~400Hz. Qualcomm: 150Hz~1500Hz. Band pass: 200Hz~600Hz. b) Maximum signal gain: >=100dB. c) Fixed-point accuracy: 0.1m. |
Magnetic field channel | Maximum signal gain: >=100db |
|
Acoustomagnetic transit time positioning mode: waveform display, acoustic and magnetic transit time display. | ||
Signal gain: adjustable from 1 to 8 levels. | ||
Magnetic field channel: adjustable from 1 to 8 levels | ||
Sound signal strength bar graph indicates, and the sound trigger threshold (0 to 99 levels) is adjustable. | ||
The electromagnetic signal strength is indicated by a bar graph, the magnetic field trigger threshold (0 to 99 levels) is adjustable, and it has a magnetic field trigger prompt function. | ||
Electromagnetic signal strength bar graph indication, adjustable magnetic field trigger threshold, with magnetic field trigger prompt function. |
||
Acoustic-magnetic time difference positioning mode: waveform display, the maximum acoustic-magnetic time difference is 80ms, which can be automatically calculated and manually analyzed; it can record the last time acoustic-magnetic time difference. |
||
Power supply: |
a) Battery: built-in lithium-ion battery pack, voltage 8.4V, capacity 2.4Ah b) Use time: continuous use time > 8 hours; c) Charger: input AC220V±10%, 50Hz; nominal output 8.4V, 1A d) Charging time: <3 hours. |
|
Display mode: 5-inch color LCD, 854*480 resolution, with touch function. | ||
Operating environment temperature: -20°C-65°C, humidity ≤90% RH, altitude <4500m. |
1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;
2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;
3 Display: 5-inch touch display.1 Sensor: Probe sensor connection port;
2 Charging: charger connection port;
3 Dedicated headphone jack.
Description
XHGX507 underground cable pipe locator is mainly used for cable fault location, cable identification, cable path and depth measurement. It can complete tasks that could only be accomplished by a few sets of instruments in the past.
Features
The large-screen LCD displays the signal strength, and the bar, arrows and voice prompts make it easy for the operator to judge the underground position of the cable and the fault point. One person can do it all.
All-digital design, clear large-screen LCD graphic display and reliable positioning
Portable and lightweight, easy to carry
Built-in rechargeable battery
Built-in ohmmeter to measure cable loop resistance
Can be used to detect insulation faults up to 2MΩ to ground
With backlight function to adapt to night operation
Built-in ohmmeter to measure cable loop resistance
Display cable depth and current
Main components
This cable pipe locator is mainly composed of transmitter and receiver, with accessories of two clamps, one A-frame and necessary connection wires.Technical Parameters
Transmitter
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz) |
Working mode | direct connection method, coupling method (caliper method), induction method |
Matching load | 5 ohms-3000 ohms |
Impedance display | 5 digits |
Overheating and over current | automatic protection |
Power output | low gear, middle gear, high gear |
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), Passive frequency 50Hz |
Antenna mode | valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame) |
Current indication | display the effective current value of the cable under test (unit: mA) |
Working temperature | -10ºC+55ºC |
Power indicator | graphic display |
Battery life | continuous work> 8 hours: intermittent work> 16 hours |
Signal strength indication | ladder diagram, digital range 0-999 |
Gain control | manual adjustment, dynamic range of 100dB |
Detection depth | the maximum detection depth is around 10 meters |
Maximum detection distance | The cable with good insulation can be up to 15km in the direct connection method |
Depth measurement | press the depth key to display three digits, the maximum depth can be measured up to 10 meters |
Accuracy | Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m |
More photos
Impact high voltage | 0~15kV |
High voltage partial pressure | 2.5 level |
Built-in capacitor | 8μF |
Discharge power | 0-900J |
Output voltage polarity | negative polarity |
Impact power | 250W @peak |
Working mode | Selectable or adjustable impulse rate and Single shot |
Minimum Output current in DC mode | 16mA at 15kV |
Length of test cable | The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long. |
Over temperature protection | 65ºC |
Over current protection | 8mA (more than 3 seconds) |
Volume(mm) | 540L×300W×450H |
Weight | not more than 25kg |
Power supply | AC220V±15%, 50Hz±2Hz(60Hz) |
Ambient temperature | -20~+60ºC |
Packing List
More photos
Welcome you contact us for more information~