Customization: | Available |
---|---|
After-sales Service: | Warranty |
Warranty: | 12mouth |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cable fault location intelligent bridge, set burn through and intelligent bridge in one. Rated voltage in burn mode is 60kV, short circuit current is 600mA, which can quickly burn high resistance fault to low resistance. The rated working current of intelligent bridge is 600mA, which greatly improves the accuracy of fault location. It is especially suitable for the insulation fault location of high voltage, large section and long complex cable system, such as the insulation fault location of complex high voltage cable with GIS terminal and cross interconnection. The location can be completed quickly without removing the GIS switch and short circuit cross interconnection.
The intelligent cable fault location bridge can be used to locate all cable insulation and sheath faults except some short line faults.
Features:
Burn through mode | The output voltage | 0~60kV Continuous adjustable |
Short circuit current | 600mA | |
A bridge model | The output voltage | 0~4kV Continuous adjustable |
Short circuit current | 600mA | |
LCD The display screen | 3.5 inch TFT Color screen | |
Positioning accuracy | ±(0.2%·L+1)m | |
Test range | 1~50000m | |
Operating keyboard | One key operation | |
The power supply | 220V AC±10%,50Hz | |
power | 2kVA,Generator power supply (greater than 2kW) | |
weight | 29kg | |
Dimensions (length × width × height) | 30cm´46cm´50cm | |
Operating temperature | -10ºC~+55ºC |
serial number | name | quantity |
1 | Cable fault location intelligent bridge main body | 1 |
2 | Bridge test box | 1 |
3 | Spare fuse (10A, 5×20) | 5 |
4 | Accessory package | 1 |
5 | Accessory bag accessories | |
5.1 | Bridge positioning test line | 1 |
5.2 | Burned through source output line | 1 |
5.3 | Bridge positioning low-resistance short-circuit | 1 |
5.4 | Special short wire for bridge positioning | 1 |
5.5 | Dedicated ground wire | 1 |
5.6 | Discharge rod ground wire | 1 |
5.7 | power cable | 1 |
5.8 | discharge rod | 1 |
Optional accessories | ||
10m low resistance short-circuit line (can be used for 110kV~220kV cables) |
1 | |
Cable breakout kit | 1 |