Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
  • Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
XHDD503C
Test Mode
Point Test
Usage
Digital Cable Tester
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Filter
200Hz-1600Hz Optional
Output Gain
16 Levels (0~112dB)
Output Impedance
350Ω
Acoustic-Magnetic Positioning Accuracy
Less Than 0.2m
Step Voltage Positioning Accuracy
Less Than 0.5m
Path Identification Accuracy
Less Than 0.5m
Transport Package
Wooden Case
Trademark
XZH TEST
Origin
China
HS Code
9031809090
Production Capacity
2000PCS/Year

Product Description

Product Description

 
The cable fault location instrument uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment.

It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.



This XHDD503C cable fault locator is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Fault. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites".



Features
1. 5-inch touch-high brightness LCD ensures visibility under sunlight.
2. Adopt acoustic and magnetic synchronous positioning technology to automatically calculate the acoustic and magnetic time difference.
3. The gain value and trigger value of the acoustic signal and magnetic signal can be manually adjusted to adapt to various environments.
 4. It has background noise reduction technology and can choose from a variety of filtering methods.
 5. It has BNR background noise reduction and mute noise reduction functions.
 6. It has path deviation indication.
 7. Equipped with multi-layer physical isolation signal sensors, waterproof grade IP65.
 8. Built-in large-capacity lithium battery, long standby time, equipped with fast charger.
9. Small and lightweight, easy to operate, and simple human-machine interface.


Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Technical specification
 
1 Filter parameters All-pass: 100Hz~1600Hz.
Low pass: 100Hz~300Hz.
Qualcomm: 160Hz~1600Hz.
Bandpass: 200Hz~600Hz.
2 Channel gain 8 levels adjustable.
3 Magnetic channel gain 8 levels adjustable.
4 Output gain 16 levels (0~112db)
5 Output impedance 350Ω
6 Acoustomagnetic positioning accuracy  less than 0.2m.
7 Path identification accuracy  less than 0.5m.
8 Power supply 4*18650 standard lithium batteries.
9 Standby time more than 8 hours.
10 Volume 428L×350W×230H
11 Weight  6.5kg.
12 Ambient temperature -25~65ºC; Relative humidity: ≤90%.


Working principle
This device uses the acoustic and magnetic synchronization method to accurately locate faults. It is a very accurate and unique positioning method. Its principle is based on the traditional acoustic point determination method and adds the detection and application of electromagnetic signals.

When the high-voltage generator performs impact discharge on the faulty cable, the sound generated by the discharge at the fault point is transmitted to the ground. The sound signal is picked up by a high-sensitivity probe. After amplification, a "pop" sound can be heard by listening with headphones.

The built-in probe of the probe receives the magnetic field signal in real time, and uses the principle that the propagation speed of the magnetic field is much higher than the propagation speed of sound to determine the distance of the fault point by detecting the time difference between the electromagnetic signal and the sound signal. Keep moving the sensor position to find the point with the smallest acoustic-magnetic time difference, then the exact location of the fault point will be below it.

Traditional acoustic measurement legal point instruments generally only use earphones to monitor, or are supplemented by the swing of the meter pointer to identify the discharge sound at the fault point. Since the discharge sound disappears in an instant and is not much different from the ambient noise, it often brings great difficulties to operators who are not very experienced. The acoustic-magnetic synchronization method effectively avoids the above problems of the traditional acoustic measurement method.
Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;
2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;
3 Display: 5-inch touch display.
 

Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
1 Sensor: Probe sensor connection port;
2 Charging: charger connection port;
3 Dedicated headphone jack.
 





-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer

Packing list
Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer


 
Welcome you contact us for more information and service.



 

Company Profile


Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer

Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
Xzh Test New Design Xhdd503c Underground Cable Fault Locator PinpointerXzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer
 

Xzh Test New Design Xhdd503c Underground Cable Fault Locator Pinpointer



 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier