Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
  • Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Find Similar Products
  • Overview
  • Product Description
  • On-site test
  • Our customers
  • Company Profile
Overview

Basic Info.

Model NO.
XHDP series
Connectors
Coaxial BNC
Test Mode
Instant Test
Usage
Audio Cable Tester
Test Region
Unformed
Cable Type
Shielded
Power
Electricity
Certification
CE
Customized
Customized
Color
Black
Transport Package
Wooden Case
Trademark
XZH TEST
Origin
Shaanxi

Product Description

Product Description

Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Ultra low frequency insulation withstand voltage tester is actually an alternative method of power frequency withstand voltage test. We know that when the power frequency voltage withstand test is carried out on large generators, cables and other test objects, because their insulation layer presents a large capacitance, a large capacity test transformer or resonant transformer is required. Such huge equipment is not only bulky and expensive, but also inconvenient to use.
In order to solve this contradiction, the power department has adopted reducing the test frequency, thereby reducing the capacity of the test power supply.

Many years of theory and practice at home and abroad have proved that using 0.1Hz ultra-low frequency voltage withstand test instead of power frequency voltage withstand test can not only have the same equivalence, but also greatly reduce the volume and weight of the equipment. Theoretically, the capacity is about one five-hundred of power frequency, and the operation is simple, which has more advantages than power frequency test.

 
Features:
1.The ultra-low frequency with rated voltage less than or equal to 50kV adopts single connection structure (a booster); The ultra-low frequency greater than 50kV adopts a series structure (two boosters are connected in series), which greatly reduces the overall weight and enhances the carrying capacity. Moreover, the two boosters can be used as ultra-low frequency of low voltage level alone.

2.Current, voltage and waveform data are directly sampled from the high voltage side, so the data is accurate.
3.It has overvoltage protection function. When the output exceeds the set voltage limit, the instrument will stop for protection, and the action time is less than 20ms.

4.It has over current protection function: it is designed as high and low voltage dual protection, and the high-voltage side can be accurately shut down for protection according to the set value; When the current at the low-voltage side exceeds the rated current, shutdown protection will be carried out, and the action time is less than 20ms.

5.The high-voltage output protection resistor is designed in the booster body, so there is no need to connect another protection resistor outside.

6.Due to the use of high and low voltage closed-loop negative feedback control circuit, the output has no capacity rise effect.

 
Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Technical parameters:

1. Output voltage ratings: See Details of Table 1
2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
3. Measurement accuracy: 3%
4. Positive and negative voltage peak errors:  ≤ 3%
5. Voltage wave form distortion: ≤ 5%
6. Use condition: indoor and outdoor; temperature: -10ºC∽+40ºC
Humidity: ≤ 85%RH
7. Power: AC50Hz, 220V ±5%

8. Power supply fuse tube: See Details of Table1   

Table 1:

Model no Rated Voltage Load Carrying
Capacity
Power
Fuse Tube   
Product Structure and Weight
XHDP-30 30kV
(Peak)
0.1Hz,≤1.1µF 8A Controller:4kg
Booster: 25kg
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF
XHDP-50 50kV
(Peak)
0.1Hz,≤1.1µF 10A Controller:4kg
Booster: 45kg
0.05Hz,≤2.2µF
 0.02Hz,≤5.5µF
0.05Hz,≤2.2µF
 0.02Hz,≤5.5µF
XHDP-80 80kV
(Peak)
0.1Hz,≤1.1µF 20A Controller: 4 kg

Primary booster (30KV): 25kg

Secondary booster (50kV): 45 kg
 0.05Hz,≤2.2µF
 0.02Hz,≤5.5µF
XHDP-90 90kV
(Peak)
0.1Hz,≤1.1µF 30A Controller: 4 kg

Primary booster (40kV): 36 kg

Secondary booster (50kV) 45 kg
0.05Hz,≤2.2µF
0.02Hz,≤5.5µF 
 

On-site test

Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester
 

Our customers

Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester

Company Profile

Multifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) TesterMultifunctional Ultra- Low Frequency Vlf AC DC Withstand Voltage Dielectric Loss (Tan delta) Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier