Test Function | Output Voltage | Measure Range | Accuracy | Resolution | ||
Insulation Resistance | 250V(±10%) | 0~10MΩ | ±3%rdg±5dgt | 0.01MΩ | ||
10~100MΩ | 0.1MΩ | |||||
100~1000MΩ | 1MΩ | |||||
1G~10GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
500V(±10%) | 0~10MΩ | ±3%rdg±5dgt | 0.01MΩ | |||
10~100MΩ | 0.1MΩ | |||||
100~1000MΩ | 1MΩ | |||||
1G~10GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
1000V(±10%) | 0~20MΩ | ±3%rdg±5dgt | 0.01MΩ | |||
20~200MΩ | 0.1MΩ | |||||
200~1000MΩ | 1MΩ | |||||
2G~20GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
2500V(±10%) | 0~2000MΩ | ±3%rdg±5dgt | 1MΩ | |||
2000MΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||||
20GΩ~200GΩ | ±20%rdg±10dgt | 0.1GΩ | ||||
5000V(±10%) | 0~2000MΩ | ±3%rdg±5dgt | 1MΩ | |||
2000MΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||||
20GΩ~200GΩ | ±20%rdg±10dgt | 0.1GΩ | ||||
Test Function | Measure Range | Accuracy | Resolution | |||
DC Voltage | DC 0.0V~1000V | ±1.5%rdg±3dgt | 0.1V | |||
AC Voltage | AC 0.0V~750V | ±1.5%rdg±3dgt | 0.1V |
Function | Insulation resistance test, AC voltage test, DC voltage measurement |
Ambient Temperature and Humidity | 23ºC±5ºC,below 75%rh |
Power | DC 9V 6-section LR14 Dry Battery Standby for more than 100 hours |
Rated Voltage | 250;500;1000;2500;5000V |
Rated Voltage Accuracy | ±10% |
Output short-circuit Current | ≥2mA |
Absorption Ratio Measurement | Have |
Polarization Index Measurement | Have |
Test Method | DC voltage drop method |
Test Voltage | DC voltage measurement |
Maximum Capacitive Load | Operates below 1uF |
Shift Gear | Automatic shifting |
Back light | Controllable gray backlight, suitable for use in dim places |
Display Mode | LCD display, gray backlight |
Measurement Indication | LED flashes during measurement |
LCD Size | 108mm×65mm |
Instrument Size | L/W/H:240mm×188mm×85mm |
Test Line | High pressure rod: red 1 meter Test line: black 1 meter green 1 meter |
Measurement Time | Voltage 2 times/sec, insulation resistance 7 seconds/time |
Line Voltage | measure below AC600V |
Data Storage | 500 groups,"MEM"storage instructions, display"FULL"symbol indicates that the storage is full |
Data Review | The "MR" symbol indicates when looking up data |
Overflow Display | "OL" symbol indicates over-range overflow |
Alarm Function | Alarm when the measured value exceeds the alarm setting value |
Battery Voltage | Low battery voltage symbol, prompt battery replacement when battery voltage is low |
Automatic Shutdown | "APO"Indicate Automatic Shutdown After 15 Minutes |
Power Consumption | Standby: About 40mA (backlight off) |
Turn on backlight: about 43mA | |
Measurement: about 75mA (backlight off) | |
Weight | Instrument:1230g (Including battery) |
Working Temperature and Humidity | -10ºC~40ºC;Below 80%rh |
Storage Temperature and Humidity | -20ºC~60ºC;Below 70%rh |
Insulation resistance | 200MΩ or more (500V between circuit and case) |
Pressure Resistance | AC 5160V/rams(Between circuit and case) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for Safety Regulations | IEC61010-1(CAT III 300V,CAT IV 150V,Pollution degree 2); |