  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
  • Xzh Test Six-Phase Microcomputer Relay Protection Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
XHJB666
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Green
Display
8.4-Inch Large-Screen
Number of Current Channels
Standard 6 Phases
Number of Voltage Channels
Standard 6 Phases
AC Current Output Range
30A/Phase or 180A (Six Parallel)
DC Current Output Range
10ADC/Phase
AC Voltage Output Range
120VAC/Phase
DC Voltage Output Range
160VDC/Phase
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi&an
Production Capacity
1000

Product Description

Product Description

XHJB66 microcomputer relay protection calibrator is a new type of miniaturized microcomputer relay protection tester fully realized by modern advanced microelectronic technology.

Product Parameters

Xzh Test Six-Phase Microcomputer Relay Protection Tester

Your logo can be put on the panel of the equipment.Each equipment got a series number.


Features:
1. Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode.
2. High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT LCD
3. The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance.
4. The output part is controlled by DSP, the operation speed is fast, the real-time digital signal processing capability is strong, the transmission frequency bandwidth is controlled, and the high-resolution D/A conversion is controlled.
5. It can complete a variety of large-scale complex verification work with high degree of automation. It can easily test and scanvarious protection settings, perform fault playback, store test data in real time, display vector graphics, and print reports online.
6. It has an independent 110V and 220V dedicated adjustable DC power output for on-site inspection.
7. The new generation TP-60A tester is equipped with 10-way opening and 8-way opening for easy self-injection test. The input contact is an empty contact and is compatible with 0~250V potential contacts, which can be intelligently and automatically recognized.
8. Provide various automatic test software modules and GPS synchronous trigger test (optional).
9. Can perform a variety of complex calibration tasks, and can easily test and scan various protection settings for fault playback. Can store test data in real time, display vector graphics, print reports, etc.
10. The design of the heat dissipation structure is reasonable, the hardware protection measures are reliable and perfect, and the power soft start function, the software self-diagnosis of the fault and the output latching function are provided.


Main technical parameters of the tester:
 




AC current output
1. 6-phase current output per phase output (effective value) 0 to 30A
2. Output accuracy ≤0.5A ±2mA
3. >0.5A 0.2%
4. Output per phase (effective value) when 3-phase current is output 0 to 60A
5. 6-phase parallel current output (RMS) 0~180A
6. Phase current allowed for a long time (effective value) 10A
7. Phase current maximum output power 400VA
8. Allowable working time for maximum output of 6-phase parallel current 10s
9. Frequency range (fundamental) 0~1000Hz
10. Harmonic times 1 to 20 times
 
DC current output
1. Current output 0~±10A / per phase, 0~20A / two-phase superposition Output accuracy 0.5
2. Maximum output load voltage 20V
 
 
AC voltage output
1. Phase voltage output (RMS) 0~120V Output accuracy 0.2 level
2. Line voltage output (RMS) 0~240V
3. Phase voltage / line voltage output work 80VA / 100VA
4. Frequency range (fundamental) 0~1000Hz
5. Harmonic number 1 to 20 times
 
DC voltage output
1. Phase voltage output amplitude 0~±160V Output accuracy 0.5 level
2. Line voltage output amplitude 0 ~ 320V
Phase voltage / line voltage output power 70VA / 140V
 
SWITCH
1. 10-channel digital input
2. Empty contact 1~20mA, 24V
3. Potential contact is connected to "0": 0 to +6V; "1": +11 V to +250 V
4. 8 pairs of switching outputs DC: 220 V / 0.2 A; AC: 220 V / 0.5 A

Time measurement range
1. 0.1ms ~ 9999s, measurement accuracy <0.1mS
 
2. volume and weight : 480×360×200mm3 19kg
If you would like to know more product related information, please contact us
 
Certifications

Xzh Test Six-Phase Microcomputer Relay Protection Tester

Packaging & Shipping

 
 

Xzh Test Six-Phase Microcomputer Relay Protection Tester

 

Company Profile

Xzh Test Six-Phase Microcomputer Relay Protection Tester

 

Xzh Test Six-Phase Microcomputer Relay Protection Tester

 

Xzh Test Six-Phase Microcomputer Relay Protection Tester

 

FAQ

Xzh Test Six-Phase Microcomputer Relay Protection Tester

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier