After-sales Service: Warranty Certificate
Warranty: 12 Months
Test Mode: One-sided Test
Usage: Digital Cable Tester
Certification: CE, ISO
Customized: Non-Customized
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XHLJ504L
Color
Black
Transport Package
Wooden Case
Trademark
XZH TEST
Origin
China Xi′an
HS Code
9031809090
Production Capacity
2000pieces /Year

Product Description

 


Product Introduction
Model Name
XHLJ504L Cable route tracer(underground cable pipe locator)

XHLJ504L cable route tracer (underground cable pipe locator) is a special instrument used to accurately detect the direction and depth of buried cables within a certain range;

The path detection is completed by the cooperation test of the path signal generator and the path signal receiver; through the cooperative operation between them, the cable path can be accurately positioned within the approximate cable buried range.

Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder

---------------------------------------------------------------------------------------------------------------------------------------------------------
The main components of path detection
Path detection is mainly composed of path signal generator and receiver

 
Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder
Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder





 Path signal generator
The path signal generator can generate high-power audio output signals, and the receiver receives the audio signals to complete the path detection function.
The main technical indicators are as follows:
a) Large output power, strong anti-vibration and anti-interference ability, stable and reliable;
b) It has reliable over-current, open-circuit, and short-circuit protection functions;
c) Output frequency: audio;
d) Output signal: intermittent, 0~50Vpp
e) Working power supply: 220V (1±10%) 50Hz (1±5%);
f) Output power: 100W;
g) Output current: 0~2A;
The path signal generator uses 220V mains power supply, and the output signal voltage and power vary with different loads. If the output terminal is short-circuited, the device will be protected immediately. After the load short-circuit state is eliminated, press the start button and the device will resume normal operation.



Path receiver
The panel is equipped with a power button, a volume increase button ( "+"), a volume decrease button ("-"), and a sound outlet. Press and hold the power button for 5 seconds to complete the power on/off operation, and use "+" and "-" to complete the volume adjustment. The display part uses a semi-circular LED bar to display the current signal strength, and 4 LEDs to indicate the battery level.

Receive the audio signal sent by the cable, so as to accurately detect the buried depth and direction of the cable.
The main performance indicators of the receiver:
Gain ≥100dB, accurate and quick search
LED display signal strength, observation is intuitive and concise
Lithium battery power supply, longer battery life
One-key switch, easy to operate
Digital volume adjustment, the sound is clearer
Easy to use, you can use it when you turn on the probe and connect it
Positioning accuracy: ±5% of depth
Depth measurement accuracy: ±5% of depth
Depth measurement range: 5 meters


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Easy to operate, and simply to judge the cable path:

Take this receiver, observe the number of lights on and listen to the sound from the speaker.

When it is close to the cable, the sound of the speaker will be loud and the indicator lights will be bright, but when it is directly above the cable, the sound of the speaker becomes the smallest and the light is also the least bright.
------------------------------------------------------------------------------------------------------------------

Operation and use of the path meter
1. Wiring of signal generator
a) Connect the 220V AC power line;
b) The positive pole of the output is connected to the good phase of the faulty cable or the normal cable, the negative pole of the output is grounded, and the three-phase end of the cable should be open to the ground. If the output signal is weak, short the end of the cable to ground. The wiring diagram is shown below.

Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder


Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder

Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder


 Output signal adjustment

After completing the wiring, turn the output adjustment counterclockwise to the end, turn on the power switch, the power indicator light is on; adjust the output knob to make the indicator head and needle point in the appropriate range. If the cable under test exceeds several kilometers, adjust the output knob to increase the output voltage. During the adjustment process, if the overload indicator is on, you need to adjust the output knob to reduce the output amplitude, and then press the start button to resume work.

2. Receiver Operation and Use
Steps for usage
a. Connect the probe, press and hold the power button for 5 seconds to turn on the receiver.
b. Path search, the line formed by the smallest point heard by the probe perpendicular to the ground is the buried path of the buried cable.
c. If you want to judge the buried depth of the cable, you can place the probe at an angle of 45degrees with the ground on the position of the cable that has been measured, and move outwards perpendicular to the path. When the sound is the smallest, the distance the probe moves is equal to Buried depth of the cable. The above-mentioned operation essentials can refer to the schematic diagram of probe placement in below picture.

Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder



Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder


That is to say, when detecting the direction of the cable path, the probe and the horizontal plane should always be kept vertical. When the probe is directly above the cable direction, the received sound is relatively the smallest, and the ground position connection with the smallest relative indication is the cable path to be tested. the direction of the location.
In addition, when detecting the buried depth of the cable path, the probe should be perpendicular to the cable and the angle between the probe and the horizontal plane should be 450. When moving the probe to one side, the sound will change from large to small, and then from small to large. Relative indication The vertical distance from the point on the smallest ground to the ground of the cable is the buried depth of the cable there.

---------------------------------------------------------------------------------------------------------------------------------------------------------

 
Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder
Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder

Welcome you contact us for more information.
Xzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder

Our team


Xzh Test Manufacturer Portable Cable Route Tracer Cable Path FinderXzh Test Manufacturer Portable Cable Route Tracer Cable Path FinderXzh Test Manufacturer Portable Cable Route Tracer Cable Path FinderXzh Test Manufacturer Portable Cable Route Tracer Cable Path Finder

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now