XHHV535-2L+XHGG502A+XHDD503C Portable Cable Fault Location system
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; accurately detect the direction and depth of the cable buried.
The portable cable fault location system is a 1-phase mobile cable test and fault location system made in a form trolley. It is designed for

| Cable fault pre-locator | XHGG502A: for cable fault distance test |
| Cable fault pinpoint locator | XHHD503C: cable fault pinpointing, WITH path auxiliary viewing function |
| High voltage surge generator | XHHV535-2L: To impact faulty cable to make it discharge |
Welcome you contact us for more information and service.
Cable fault pre-location: with the reflectometer XHGG502A based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(multi-shot).
XHGG502A cable fault pre-locator
Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(single-shot/ multi-shot).
There are three test mode of XHGG502A, low voltage pulse, high voltage flashover, ARC multi-shot.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502A.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502A
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502A. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHDD503C
Features
1. 5-inch touch-high brightness LCD ensures visibility under sunlight.
2. Adopt acoustic and magnetic synchronous positioning technology to automatically calculate the acoustic and magnetic time difference.
3. The gain value and trigger value of the acoustic signal and magnetic signal can be manually adjusted to adapt to various environments.
4. It has background noise reduction technology and can choose from a variety of filtering methods.
5. It has BNR background noise reduction and mute noise reduction functions.
6. It has path deviation indication.
7. Equipped with multi-layer physical isolation signal sensors, waterproof grade IP65.
8. Built-in large-capacity lithium battery, long standby time, equipped with fast charger.
9. Small and lightweight, easy to operate, and simple human-machine interface.
| 1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
| 2 | Channel gain | 8 levels adjustable.1-8dB adjustable |
| 3 | Magnetic channel gain | 8 levels adjustable.1-8dB adjustable |
| 4 | Output gain | 16 levels (0~112db) |
| 5 | Output impedance | 350Ω |
| Safety- Volume limiting to | 84dB | |
| 6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
| 7 | Path identification accuracy | less than 0.5m. |
| 8 | Power supply | 4*18650 standard lithium batteries. |
| 9 | Standby time | more than 8 hours. |
| Charging time | 3 hours | |
| 10 | Volume | 428L×350W×230H |
| 11 | Screen pixels | 854*480 |
| 12 | Brightness | 800nit |
| 13 | Transmission speed unit | 0-100ms |
| 14 | Accuracy | 1ms |
| 15 | Sound bandwidth | 100-1.6khz |
| 16 | Magnetic coil bandwidth | 100-20kHZ |
| 17 | Both sound and magnetism are | greater than 75db |
| 18 | Weight | 6.5kg. |
| 19 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHHV535-2L High voltage surge generator
The XHHV535-2L high voltage pulse generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.
This device integrates a high-voltage DC source, an energy storage capacitor, a discharge ball device, an automatic discharge device, and a voltage level switching device into a cart-type high-end experimental instrument. It is a trolley-type high-end experimental instrument. The equipment completely solves the problems of ease of use, portability, safety and reliability of traditional experimental devices.
When the XHHV535-2Ltrolley-type high-voltage pulse generator is in use, after selecting the function switch, press the start button to perform high-voltage boosting work. After use, press the stop button, and the internal system will automatically release the remaining high voltage on the accumulator.
| Impact high voltage | 0~32kV |
| High voltage partial pressure | 2.5 level |
| Built-in capacitor | 2μF |
| Discharge power | 0-1024J |
| Output voltage polarity | negative polarity |
| Impact power | 250W@peak |
| Working mode | Selectable or adjustable impulse rate and Single shot |
| Minimum Output current in DC mode | 7.5mA at 32kV |
| Length of test cable | The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long. |
| Over temperature protection | 65ºC |
| Over current protection | 8mA (more than 3 seconds) |
| Volume(mm) | 540L×300W×450H |
| Weight | not more than 25kg |
| Power supply | AC220V±15%, 50Hz±2Hz(60Hz) |
| Ambient temperature | -20~+60ºC |
| Cable length | High voltage output cable - 2 meters, ground wires - 2.5 meters, power cable - 1.8 meters. |
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------