China Factory Xzh Test Wholesale Price Integrated High Voltage Pulse Generator with Arc Cable Fault Locator
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Warranty Certificate |
| Warranty: | 1 Year |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Diamond Member Since 2021
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2022-08-12
Number of Employees
5
Find Similar Products
Basic Info.
- Model NO.
- XHHV535-4TSC+XHGG502A
- Transport Package
- Wooden Case
- Specification
- mm
- Trademark
- XZH TEST
- Origin
- China Xi'an
- HS Code
- 9031809090
- Production Capacity
- 2000pieces /Year
Product Description
underground cable fault locator testing set
System purpose
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length;
| Product name | Model No. | Qty.(unit) | main function |
| cable fault pre locator | XHGG502A | 1 | For underground cable fault rough distance measurement |
| high voltage pulse generator with ARC filter | XHHV535-4TSC | 1 | surge discharging for underground cable fault locating & DC high voltage withstand voltage test equipment |
III. Main technical parameters of the system: :
1) Industrial computer control, touch operation mode, strong anti-interference ability;
2)System functions: fault distance measurement, fault pinpoint location, propagation speed test, cable path search, buried depth detection;
3)Test methods: low-voltage pulse, flashover method, multiple pulse method, audio method, acousto-magnetic synchronization method, valley method, peak method,electromagnetic induction method, etc.;
4)Test range: test distance: >60km, detection depth: 2-5m;
5)Measurement accuracy: Rough measurement error: ±10m (absolute value) or 1% (relative value), fine measurement error: ±0.2m (fixed point, path, depth);
6)Sampling frequency: 400MHz, minimum resolution 0.5m (100m/us)
7)Sampling method: automatic continuous sampling, never miss any discharge waveform.
8)Low voltage pulse: Width: Adaptive Amplitude: 400Vpp
9)Output power: path power: 100W
10)Shock high voltage: three voltage 8/16/32kV adjustable
11)Short circuit current:0~320mA
12)Burn through power:0~2048J

Cable fault pre-locator(XHGG502A)
1) Industrial computer control, touch operation mode, strong anti-interference ability;
2)System functions: fault distance measurement, fault pinpoint location, propagation speed test, cable path search, buried depth detection;
3)Test methods: low-voltage pulse, flashover method, multiple pulse method, audio method, acousto-magnetic synchronization method, valley method, peak method,electromagnetic induction method, etc.;
4)Test range: test distance: >60km, detection depth: 2-5m;
5)Measurement accuracy: Rough measurement error: ±10m (absolute value) or 1% (relative value), fine measurement error: ±0.2m (fixed point, path, depth);
6)Sampling frequency: 400MHz, minimum resolution 0.5m (100m/us)
7)Sampling method: automatic continuous sampling, never miss any discharge waveform.
8)Low voltage pulse: Width: Adaptive Amplitude: 400Vpp
9)Output power: path power: 100W
10)Shock high voltage: three voltage 8/16/32kV adjustable
11)Short circuit current:0~320mA
12)Burn through power:0~2048J
High voltage surge generator XHHV535-4TSC
| Impact high voltage | 0 ~ 32kV, 0 ~ 16kV, 0 ~ 8kV three regulation |
| High voltage side current | 0 ~ 60mA |
| High pressure accuracy | 2.5 |
| Built-in capacitance | 4μF/32kV, 16μF/16kV, 64μF/8kV three adjustment |
| Discharge energy | 2048J@each voltage level |
| Output voltage polarity | negative polarity |
| Impact time | automatic impact about 7 seconds, manual impact any control time |
| Overcurrent protection | 9A(greater than 5S) low voltage side |
| Overtemperature protection | 105ºC |
| Maximum power | 2000W |
| Volume | 740L×520W×880H |
| Weight | no more than 130kg |
| Working power supply | AC 220V±10% 50Hz±2Hz/60Hz |
| Ambient temperature | -25 ~ +65ºC |

Cable fault pre-locator(XHGG502A)

| ARC Cable Fault pre-locator XHGG502A |
Pre-location method | LV TDR (low voltage pulse method/ impulse reflection method) |
| HV TDR(high voltage flashover method /single impulse method ) | ||
| ARC (multiple impulse arc reflection method) | ||
| ICE (impulse current method) DECAY (voltage decay method) |
||
| Automatically test velocity speed | ||
| Display | 10.1 inch industrial-grade computer control, touch operation mode | |
| System | Windows operating, automatic generate test reports. | |
| Function | Speed, resistance, distance measurement | |
| Sampling frequency | 1MHz~400MHz | |
| Low voltage pulse amplitude | 300V±15% | |
| Pulse width | 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS; | |
| Measuring distance | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km/120km; | |
| Reading resolution | 0.07m; | |
| Test accuracy | ≤±(0.5%×L+1m), L is the cable length; | |
| Cable length choice | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km | |
| Pulse coupler withstand voltage | 35kV DC | |
| Test blind zone | ≤10m | |
| Data storage | Stores more than 8,000 records of low-voltage pulse and high-voltage flashover waveforms, and more than 250 records of multiple pulse waveforms. | |
| Power supply | charging AC110V~240V, 50Hz/60Hz; Built-in 5200mAH lithium battery power supply; charging time is about 2 hours, working time is more than 5 hours; |
|
| Communication | With standard USB interface | |
| Working conditions | Temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg; | |
| Volume and weight | Cable fault tester L358mm×W284mm×H168mm-4.7kg; Pulse coupler L430mm×W380mm×H220mm-10kg. |









Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Cable diagnosis and fault location system
- Cable fault locator set
- China Factory Xzh Test Wholesale Price Integrated High Voltage Pulse Generator with Arc Cable Fault Locator
Related Categories
Hot Searches
More