Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
  • Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
XHHV510-10L
Type
Pulse Signal Generator
Channel
1
Display
Digital
Transport Package
Wooden Case Filled with Foam
Trademark
XZH TEST
Origin
China
Production Capacity
2000PCS/Year

Product Description

Product Description

The high-voltage pulse generator fully meets DL/T846-2016 "General Technical Conditions for High-Voltage Test Equipment" and DL/T474-2017 "Implementation Guidelines for Field Insulation Tests". Mainly used for shock discharge during cable fault test.It can also be used for DC withstand voltage test of other electrical equipment.

This device integrates DC high voltage source, energy storage capacitor, discharge ball gap, etc. This device completely replaces the traditional hundreds of kilograms of test transformers, operation boxes and pulse energy storage capacitors (generally a set of 5kVA transformers are more than 60 kilograms, control The box is more than 30 kg, and the pulse energy storage capacitor is more than 20 kg).

The power supply adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, which makes the whole machine simple in structure and ultra-light in weight. In order to retain people's habit of using transformers and operation boxes to generate DC high voltage, this pulse generator adopts humanized design and operation mode, which is safe and reliable. Really achieve the effect of not being damaged by impact, and the short circuit of high voltage to ground can also work normally. It is currently the lightest and most user-friendly portable DC shock high-voltage equipment. It is an ideal product for power cable fault detection.





The panel can be customized in English version.
Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
 

Features

 With over-current, over-voltage, overheating automatic protection function;
★ With DC withstand voltage, impact discharge function;
 The high-voltage pulse output is uniform and controllable;
 Super short-circuit protection function, which can make the high-voltage output directly short-circuit to the ground;
 It has dual 2.5-level pointer meters for current and voltage display, which is intuitive and clear, and it is clear at a glance whether the fault point is fully discharged, and the discharge process is reflected in real time;
 High-voltage side voltage measurement, real-time and accurate;
 With zero start protection and potentiometer zero output function, it is safe and reliable;
 Unique high-voltage measurement design, in the stop state, the voltmeter can indicate the capacitor voltage in real time;
 The discharge time can be arbitrarily set within the appropriate interval;
 

     Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location                                                         
 


 
Product Parameters

 

 
Impact high voltage 0-12KV
High voltage partial pressure Voltage Accuracy 2.5 grade
Built-in capacitor 12μF
Working power AC 220V ± 10% 50Hz ± 2Hz
Discharge power 0-864 J
Ambient temperature -20 ~ + 50 ºC
Impact time 3 ~ 7seconds
Impact power 400W
Over current protection 8mA (more than 3 seconds)
Over temperature protection 85 ºC
Volume/size  420L × 325W × 480(mm)
 
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location




1. Safety ground: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified or electric shock to personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to prevent high-voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled under the high-voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage output is in the zero position. When the light is on, the start button is valid. If the start button light is not on after turning on the power switch, turn the voltage adjustment knob counterclockwise until the light is on. When the button light is on, press this button to start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, the high-voltage light goes out, and the internal discharge ball stops working. When the stop key is on, it means there is high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current protection function has started; when it is popped up, it means that the instrument has triggered the over-current protection.
 

8. Voltage adjustment: After turning on the device, you must first turn the knob counterclockwise to the end, press the start button, and then adjust clockwise to increase the output high voltage from small to large, and adjust counterclockwise to reduce the output high voltage from large to small.
 
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns off the system power.

10. The fuse holder: the place where the fuse of the AC 220V power supply system is installed.

11. Power socket: the working power supply of the instrument, AC 220V connection port.

12. Time setting: Set the discharge time interval.

 
13. Ammeter: indication of the current on the high voltage side.
 

14. Voltmeter: high voltage output voltage indicating kV meter.

15. High-voltage output (EMP): When impacting discharge, connect the high-voltage output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage output line.

----------------------------------------------------------------------------------------------------------------
Packing list

Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location

Welcome you contact us for more information


------------------------------------------------------------------------------------------------------------------------------------



Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location

 

Packaging: Wooden case filled with foam 

Shipping: by Air, Sea, Express, etc.

Shipping time: 7-15 days if it's in stock. 

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Application
Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
 

Company Profile

 



Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location




Portable 10kv 500j High Voltage Pulse Generator for Underground Cable Fault Location
 
FAQ
 

 

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: What is your terms of payment ?

A: Payment<=1000USD, 100% in advance. 




 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier