• Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
  • Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
  • Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector

After-sales Service: Warranty Certificate
Warranty: 12 Months
Test Mode: Saved Test
Test Region: Forming Cable
Cable Type: CAT3
Certification: CE
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Packaging & Shipping
  • Our Advantages
  • On-site Test
  • FAQ
Overview

Basic Info.

Model NO.
XHSP1700
Customized
Customized
Color
Black
Test Frequency
128Hz/111Hz/105Hz/94Hz(Afc)
Resolution
0.5m
Transport Package
Wooden Box Filled with Foam Inside
Specification
350mm*280mm*170mm
Trademark
XHYZ1668
Origin
China Xi′an
HS Code
8543201000
Production Capacity
1000pieces/Year

Product Description

Main technical datas
• operating display: 5.7 inch periodic lattice Chinesize color liquid crystal (can be equipped with touch screen)
• temperature control area: 6 ways • temperature: room temperature above 5 ºC ~ 400 ºC, incremental:1 ºC, accuracy :± 0.1 ºC
• temperature-programmed order: 16 order
• Temperature program rate: 0.1 ~ 39 ºC /min (common type); 0.1 ~ 80 ºC /min (high speed)
• the gas control: optional pressure flow control mode of the mechanical valve control mode, electronic
• gas pressure, flow measurement: pointer type pressure meter or electronic pressure, flow pattern
• all electronic gas pressure, flow measurement system The single module maximum measuring way: 16 Range: 0 ~ 0.3MPa       (pressure); 0 ~ 500sccm (flow) Resolution: 0.01kPa (pressure); 0.01sccm (flow)
• EPC, EFC work mode: 3kinds:constant current mode, constant voltage mode, bypass mode
• EPC, EFC working gas: 4kinds:nitrogen, air, hydrogen, helium, argon
• EPC, EFC L: 4 order EPC, EFC: pressure control range: 0 ~ 0.6MPa; flow rate of 0 ~ 100sccm or 0 ~ 500sccm (air);
• EPC, EFC control precision pressure 0.01kPa; flow rate: 0.01sccm;
• external events: 4 road, 4 road; auxiliary control output
• injector types: packed column sample, the capillary inlet, six valve gas sampling, automatic headspace sampling.
• detector number: 3 (up); FID, TCD, ECD, FPD and NPD.
• start sampling: manual, automatic optional
• communication interface: Ethernet: IEEE802.3

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
Detector technology index
Hydrogen flame ionization detector (FID)
•The limit of detection: ≤ 1×10-11g/s (sixteen alkyl);
• baseline noise: ≤5×10-14A
• baseline drift: ≤1×10-13A/30min
• linear range:≥106
Thermal conductivity detector (TCD)
• sensitivity: S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged ,optional.)
• baseline noise: ≤ 20 μ V
• baseline drift: ≤ 30 μ V/30min
• linear range:≥104
Electron capture detector (ECD)
•The limit of detection: ≤ 1×10-13g/ml(C 666 - isooctane solution)
• baseline noise: ≤ 0.03mV
• baseline drift: ≤ 0.2mV/30min
• linear range: 103
• source: 63Ni
Flame photometric detector (FPD)
•The limit of detection: (S) ≤5×10-11g/s, (P) ≤1×10-12g/s; methyl parathion - ethanol solution)
• baseline noise: ≤ 3×10-13A
• baseline drift: ≤2×10-12A/30min
• linear range: To sulfur≥102, To P ≥103

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
 

 

Xi'an Xu&Hui Electromechanical Technology Co.,Ltd are one of famous brand of electrical equipment tester manufacturer in China, mainly produced underground cable fault locator, capacitors, insulation resistance tester, transformer oil tester, high voltage generator and earth resistance tester etc. We have several patents in this industry, and our products are export well in the global market, such as America, Brazil, Turkey, Russian,Israel, Thailand, India, etc. 
Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector

 

Packaging & Shipping

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization DetectorXhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector
 

Our Advantages

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization DetectorXhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector

On-site Test

Xhsp1700 Lab Universal High-Performance Gas Analyzer Gas Chromatograph with Flame Ionization Detector

FAQ

Q: Are you trading company or manufacturer ?

A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A:No, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. 

  
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now