Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: Warranty Certificate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
  • Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
XHJF Series
Transport Package
Wooden
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
100 Pieces /Year

Product Description

 

 

XHJF Series partial discharge tester

This instrument is designed for collecting and detecting partial discharge signals emitted from insulation defects in electric equipment. The absence of discharge signals does not necessarily indicate the absence of discharge activity in the equipment, as discharge sources often have a latent period and insulation performance may also fail due to other reasons beyond partial discharge. If significant discharge is detected in equipment connected to medium and high voltage power systems, the relevant responsible units should be notified immediately.


Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Partial discharge is a sign and manifestation of insulation deterioration in power equipment, and it is also the cause of further insulation deterioration.  Since the consequences of insulation breakdown are often serious, it is particularly important to conduct partial discharge detection on power equipment.  The local discharge of electrical equipment belongs to electrical discharge that will not completely short-circuit the electrodes.

Although the amplitude of this discharge is usually small, it can continuously degrade the insulation performance and may eventually lead to failure.  Live partial discharge detection provides a fast and simple method to identify potential insulation faults that may cause power outages or personnel injuries.

This instrument uses high-frequency detection technology to measure partial discharge and comprehensively applies computer technology, ultrasonic, radio frequency, transient waveform sampling technology, analog electronic technology, high-speed signal acquisition technology, and advanced digital signal processing technology.

It is developed based on the Linux operating system platform, providing 2D and 3D maps of partial discharge, amplitude phase spectrum waveform, and discharge signal quantification value.  By statically or dynamically observing and analyzing the partial discharge pulse waveform of a single or multiple cycles in detail, the partial discharge condition of electrical equipment can be evaluated well.  It is suitable for daily inspection of the insulation performance of high-voltage cables, power transformers, and other electrical equipment.  It has the characteristics of high sensitivity and strong adaptability and can effectively detect related insulation defects.  It is an ideal tool for state detection of power equipment during live operation.


Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester

Product Parameters


Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester


Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
 
Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester


 

Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester(1) MODE key, used to switch measurement modes.
(2) Power button, press the button to turn on the instrument when it is in shutdown state; in the power-on state, press and hold the power button for two seconds to turn off the instrument.
(3) Four directional keys, used for option switching, setting value modification, and chart type switching.
(4) ESC key, to exit or close a certain page. In the waveform interface, press and hold the key for two seconds to screenshot and save the current waveform.
(5) OK key, used as a confirmation key, to enter a certain page or set a certain parameter.
(6) AA/AE, contact ultrasound or non-contact ultrasound input terminal.
(7) HF, high-frequency sensor input terminal.
(8) TEV, transient voltage sensor input terminal.
(9) UHF, ultra-high frequency sensor input terminal.
(10) USB port, connects to a USB drive (FAT32 format) to save images and other files.
(11) Charger interface, input port for the charger.
(12) Headphone jack, for listening to ultrasound partial discharge with headphones.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Main features
1. Provides quick on-site detection of high-voltage electrical equipment, especially for partial discharge conditions of high-voltage
cables. It is convenient to use, small in size, lightweight, and easy to carry.
2. The partial discharge detection sensor circuit design utilizes advanced RF signal processing, high-frequency signal processing, and
weak signal processing technology. It uses high-precision AD conversion and high-speed digital signal processing chips for digital signal
processing, with good anti-interference performance and measurement accuracy.
3. Multiple methods are used to detect partial discharge signals, including ultrasonic, transient earth wave, high frequency, and very high-frequency detection.
4. It has a built-in non-contact air-coupled sensor, and can be configured with an external surface-coupled ultrasonic sensor.
5. It provides various analysis window options, including phase-linear, PRPD, and PRPS to analyze partial discharge test data.
6. It supports data storage, viewing, and deletion functions.
7. It supports waveform data recording function.
8. It supports multiple levels of attention and alarm threshold settings. Different amplitude colors provide intuitive prompts to indicate potential
issues.
9. It is powered by a large-capacity lithium battery, providing 6 to 8 hours of continuous operation on a single charge.
10. It uses Linux as the embedded operating system, making it convenient for future function expansion and integration with IoT technology.

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Technical indicators

 

Non-contact Ultrasonic Sensor (AA)
Central frequency of the sensor 40KHz ± 1KHz
Measurement range -7~68dBuV
Resolution 0.1dB
Linearity error <±20%
Sensor form Bendable form/Focusing form
Contact Ultrasonic Sensor (AE)
Detection frequency band: 20KHz~80KHz (SF6 gas-insulated power
equipment)
80KHz~200KHz (Oil-filled power equipment)
Dynamic measurement range 60dB
Resolution: 0.1dB
Linearity error: <±20%
Transient Earth Voltage Sensor (TEV)
Detection frequency band: 3MHz~100MHz
Measurement range: 0~60dBmV
Resolution: 0.1dB
Linearity error: <±20%
Ultra-High Frequency Sensor (UHF)
Detection frequency band: 300MHz~1500MHz
Measurement range: -70dBm to -10dBm
Effective sensor height: ≥10mm
Resolution: 0.1dBm
High-Frequency Sensor (HF)
Detection frequency band: 0.3MHz~30MHz
Measurement range: 0~70dB
Gain: -30~20dB
Resolution: 0.1dB
Transmission impedance: ≥10mV/mA
Input impedance: 50Ω
Machine Parameters
Operating environment: Temperature -20ºC~50ºC, humidity 0~85%
Display screen: High-definition color 5.6-inch TFT LCD display,
resolution 480*640
Mainframe size: 230x170x48mm
Mainframe weight: 1.35Kg
Battery life: About 6 hours



-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------




Welcome you contact us for more professional service~


 

 

 

 

 

Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester
Xhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge TesterXhjf Series Transformer Cable High Voltage Switchgear Partial Discharge Tester










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier