China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator

Product Details
Customization: Available
After-sales Service: Technical Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
  • China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
Find Similar Products
  • Overview
  • Product Description
  • Product Features
  • Product Parameters
Overview

Basic Info.

Model NO.
XHHG521A
Test Mode
Saved Test
Test Region
Forming Cable
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
No-Load Voltage
0~4000V
Short Circuit Current
≥40mA
Positioning Accuracy
± (0.2% * L ± 1) Meters
Weight
5.5kg
Working Power Supply
AC 220V+/-10% 50Hz
Transport Package
Wooden
Specification
5.5kg
Trademark
XZH TEST
Origin
China Xi′an
HS Code
854320100
Production Capacity
100 Pieces /Year

Product Description

 

 
 

Product Description

Product Description

Introduction
The cable outer sheath fault tester XHHG521A is designed based on the MURRAY bridge principle and can be used to locate the breakdown points of various wires and cables and the defect points that have no breakdown but low insulation resistance values.

The equipment uses an electric voltage regulator and an R-type transformer to form a high-voltage constant current source, and the button operation can increase or decrease the voltage. The no-load voltage is 7500V, the short-circuit current is 100mA, and a high-sensitivity amplifier and galvanometer are used to indicate balance. It forms a balanced bridge with a proportional potentiometer, and the whole is placed at a high potential. The measurement cable is a specially designed two-core high-voltage rubber cable. The four-terminal resistance measurement method is used to avoid errors caused by lead resistance. The entire panel is at low potential. One-touch operation, enter the cable length and automatically calculate the fault distance. The high voltage source and bridge are integrated in a portable protective box. Therefore, the device has high voltage, light weight, easy operation and safe use.
China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
High voltage bridges are particularly suitable for
1. The high-resistance breakdown point of the cable after laying, especially the linear high-resistance breakdown point that is difficult to burn into low resistance, such as the linear high-resistance breakdown of the cable intermediate joint.
2. Flashover type breakdown point. After breakdown, the constant current source can maintain the arc, a stable current flows through the bridge, and the bridge has sufficient sensitivity.
3. Defects that have not yet broken down but have low resistance, such as insulation defects found with a megohmmeter that have low cable resistance but do not break down under the operating voltage.

China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator

Product Features

  1. Output voltage is adjustable;
  2. Has high accuracy and stability;
  3. Adopt high-sensitivity amplifier and galvanometer to indicate balance;
  4. Zero protection;
  5. Automatically test fault points, but retain manual testing functions;
  6. Compared with the wave reflection method, the bridge balance method has no blind area and is used to determine the breakdown point of short cables and near the ends.

Product Parameters

No load voltage ≥7500V
Short circuit current ≥100mA (when adjusting balance, it is recommended to set it at 5~40mA);
Positioning accuracy ±(0.2%·L±1)m
Weight 25kg
Power supply  AC 220V (±10%), 50Hz±1Hz; 8.4V built-in battery.

Application


 

China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator
China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator

China Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault PrelocatorChina Manufacturing Supplier High Voltage Underground Digital Cable Outer Sheath Fault Prelocator

 

 













 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier