DC High Voltage Generator DC Hipot Testing Device

Product Details
Customization: Available
Type: Box Transformer
Altitude: <1000m
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • DC High Voltage Generator DC Hipot Testing Device
  • DC High Voltage Generator DC Hipot Testing Device
  • DC High Voltage Generator DC Hipot Testing Device
  • DC High Voltage Generator DC Hipot Testing Device
  • DC High Voltage Generator DC Hipot Testing Device
  • DC High Voltage Generator DC Hipot Testing Device
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
XHZG-120/3
Relative Humidity
<85%
DC Voltage Output
120kv
DC Current Output
3mA
Transport Package
Wooden Cases
Specification
66x49x23cm
Trademark
XZH TEST
Origin
Shaanxi

Product Description

Product Description
DC High Voltage Generator DC Hipot Testing Device
The DC high-voltage tester is mainly applicable to the DC withstand voltage test or DC leakage current test of zinc oxide arrester, power cable, transformer, circuit breaker, generator and other high-voltage electrical equipment by the power department of electric power department, industry and mining, metallurgy, iron and steel and other enterprises.
DC High Voltage Generator DC Hipot Testing Device
DC High Voltage Generator DC Hipot Testing Device

Features:
XHZG DC high voltage generator. Using AIPWM technology, the inaccurate linearity of PWM technology is adjusted, and the accuracy of the instrument is greatly improved. The AI technology screen is used to set overvoltage protection and overcurrent protection, which replaces the problem that the digital dial switch can only set the voltage value, but can not set the current value and voltage drift. 0.75U DC 1mA function button, convenient for zinc oxide arrester test, accuracy ≤ 0.5%.                        The timing function under any voltage and current, total time T1 and sectional timing T2 are added. The instrument adds the functions of perpetual calendar and time.
*The case adopts portable case, which is easy to carry.
*Using AIPWM technology, the  inaccurate linearity of PWM is adjusted, and the accuracy is greatly improved. Ripple coefficient ≤ 1%.
*AI zinc oxide arrester and oil immersed transformer measurement function. The experimental report can be saved directly, and the accuracy is ≤ 0.5%. 0.75U DC 1mA manual hold.
*AI technology is used to set overvoltage protection and overcurrent protection, which replaces the problem that the digital dial switch can only set the voltage value, but can not set the current value and voltage drift. Error ≤ 1%
*Full range smooth voltage regulation, voltage regulation accuracy ≤ 0.5%, stability ≤ 0.5%, voltage and current error ≤ 0.5% ± 1 word
*With total time T1 and sectional timing T2, and timing function under any voltage and current.
*The instrument adds the functions of perpetual calendar and time.

 

DC High Voltage Generator DC Hipot Testing Device
DC High Voltage Generator DC Hipot Testing Device
DC High Voltage Generator DC Hipot Testing Device
Product Parameters
 
 Specifications

technical parameter

 
60/2/3 120/2/3 60/5/10 120/5/10
Output voltage (kV) 60 120 60 120
Output current  (mA) 2/3 2/3 5/10 5/10
Output power(W) 120/180 240/360 300/600 600/120
Charging current  (mA) 3/4.5 3/4.5 7.5 7.5
Weight of control box(kg) 11.6 13 16 17.6
Weight of pressure doubling cylinder (kg) 2.3 3.6 5.8 6.3
Specification of pressure doubling
cylinder (mm)
Ф90
340
Ф90
470
Ф110
480
Ф110
530
Voltage measurement error ± 0.5% (full scale) ± 1 word
Current measurement error ± 0.5% (full scale) ± 1 word
Overvoltage setting error AI technology sets overvoltage protection and overcurrent protection error≤0.5%
0.75 switching error High precision 0.75U DC 1mA one touch button (precision ≤ 0.5%);Most suitable for zinc oxide arrester test
Most suitable for zinc oxide arrester test
Ripple coefficient ≤0.5%
operation mode Intermittent use: rated load for 30 minutes
1.1 times of rated voltage: 10 minutes
work environment temperature:-10ºC~+40ºC
Relative humidity: no more than 85% at room temperature of 25 ºC (no condensation)
Altitude: below 1500 meters
Capacitive load The capacitance of the tested object is unlimited
Structural features Electrical insulation double pressure cylinder
Air insulation, no leakage
Company Profile
DC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing DeviceDC High Voltage Generator DC Hipot Testing Device