| Item | Parameter | |
| Usage | Class P/TP CT & VT | |
| Output | 0~180Vrms,12Arms,36A(peak value) | |
| Voltage measurement accuracy | ±0.2% | |
| CT Ratio | Range | 1~40000 |
| accuracy | ±0.1%-0.5% | |
| PT Ratio | Range | 1~35000 |
| accuracy | ±0.1%-0.5% | |
| Phase | Range | ±5min |
| accuracy | 0.5min | |
| DC resistance | Range | 0~600Ω |
| accuracy | ±5%±2mΩ | |
| Burden | Range | 0~1000VA |
| accuracy | ±0.5%±0.02VA | |
| Power supply | AC220V±10%,50Hz | |
| Environmental Conditions | Operating temperature :-10οC~50οC,Humidity :≤90% | |
| Weight and Dimensions | Dimensions:340 mm×300 mm×150mm,Weight<9kg | |