Customization: | Available |
---|---|
After-sales Service: | Warranty Certificate |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
XHDD503B Digital cable fault pinpointer
Introduction
Cable fault locator XHDD503B uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.
Technical indicators
Acoustic-magnetic synchronous fixed-point function |
||
Acoustic-magnetic synchronous fixed-point function |
Sound channel | a) Bandwidth All pass: 100Hz~1500Hz. Low pass: 100Hz~400Hz. Qualcomm: 150Hz~1500Hz. Band pass: 200Hz~600Hz. b) Maximum signal gain: >=100dB. c) Fixed-point accuracy: 0.1m. |
Magnetic field channel | Maximum signal gain: >=100db |
|
Acoustomagnetic transit time positioning mode: waveform display, acoustic and magnetic transit time display. | ||
Signal gain: adjustable from 1 to 8 levels. | ||
Magnetic field channel: adjustable from 1 to 8 levels | ||
Sound signal strength bar graph indicates, and the sound trigger threshold (0 to 99 levels) is adjustable. | ||
The electromagnetic signal strength is indicated by a bar graph, the magnetic field trigger threshold (0 to 99 levels) is adjustable, and it has a magnetic field trigger prompt function. | ||
Electromagnetic signal strength bar graph indication, adjustable magnetic field trigger threshold, with magnetic field trigger prompt function. |
||
Acoustic-magnetic time difference positioning mode: waveform display, the maximum acoustic-magnetic time difference is 80ms, which can be automatically calculated and manually analyzed; it can record the last time acoustic-magnetic time difference. |
||
Power supply: |
a) Battery: built-in lithium-ion battery pack, voltage 8.4V, capacity 2.4Ah b) Use time: continuous use time > 8 hours; c) Charger: input AC220V±10%, 50Hz; nominal output 8.4V, 1A d) Charging time: <3 hours. |
|
Display mode: 5-inch color LCD, 854*480 resolution, with touch function. | ||
Operating environment temperature: -20°C-65°C, humidity ≤90% RH, altitude <4500m. |
1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;
2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;
3 Display: 5-inch touch display.1 Sensor: Probe sensor connection port;
2 Charging: charger connection port;
3 Dedicated headphone jack.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHGX507 Cable Fault Comprehensive TesterDescription
XHGX507 underground cable pipe locator is mainly used for cable fault location, cable identification, cable path and depth measurement. It can complete tasks that could only be accomplished by a few sets of instruments in the past.
Features
The large-screen LCD displays the signal strength, and the bar, arrows and voice prompts make it easy for the operator to judge the underground position of the cable and the fault point. One person can do it all.
All-digital design, clear large-screen LCD graphic display and reliable positioning
Portable and lightweight, easy to carry
Built-in rechargeable battery
Built-in ohmmeter to measure cable loop resistance
Can be used to detect insulation faults up to 2MΩ to ground
With backlight function to adapt to night operation
Built-in ohmmeter to measure cable loop resistance
Display cable depth and current
Main components
This cable pipe locator is mainly composed of transmitter and receiver, with accessories of two clamps, one A-frame and necessary connection wires.Technical Parameters
Transmitter
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz) |
Working mode | direct connection method, coupling method (caliper method), induction method |
Matching load | 5 ohms-3000 ohms |
Impedance display | 5 digits |
Overheating and over current | automatic protection |
Power output | low gear, middle gear, high gear |
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), Passive frequency 50Hz |
Antenna mode | valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame) |
Current indication | display the effective current value of the cable under test (unit: mA) |
Working temperature | -10ºC+55ºC |
Power indicator | graphic display |
Battery life | continuous work> 8 hours: intermittent work> 16 hours |
Signal strength indication | ladder diagram, digital range 0-999 |
Gain control | manual adjustment, dynamic range of 100dB |
Detection depth | the maximum detection depth is around 10 meters |
Maximum detection distance | The cable with good insulation can be up to 15km in the direct connection method |
Depth measurement | press the depth key to display three digits, the maximum depth can be measured up to 10 meters |
Accuracy | Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m |
More photos
---------------------------------------------------------------------------------------------------------------------------------------------------------------------
Cable fault pre-locator(XHGG502)Introduction
XHGG502 Cable Fault Pre Locator is a special instrument for measuring and analyzing power cable status and fault distance. It combines modern electronic technology and computer technology to realize signal filtering, acquisition, data processing, graphic display and graphic analysis to complete cable speed measurement, cable Length test, cable fault distance test.
Main features
• The reflected signal sent by the pulse coupler is automatically displayed, and the full-length waveform of the cable open circuit is displayed at the same time.
• Automatic calculation and display of fault distance;
• It has the function of storing massive test waveforms: the waveforms obtained from the field test can be conveniently stored in the instrument according to the specified order, and can be recalled and observed at any time;
• With standard printer USB interface;
• Simple operation and high reliability. Has a very high cost performance;
• Built-in polymer lithium battery power supply, which can test cable open circuit and low resistance short circuit fault in no power supply environment.
Technical parameters
Sampling frequency | 400MHz |
Minimum resolution | 0.5m (100m/us) |
Low voltage pulse width | 0.2uS/2uS/4uS |
Test blind zone | ≤20m |
Ranging range | ≥68km |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
There are three test cable lengths | <1km (short distance); <3km (medium distance); >3km (long distance), (low-voltage pulse test amplitude: 400Vpp) |
Pulse coupler withstand voltage | DC 35kV |
Measuring pulse | Low voltage pulse 300V±10% |
Output impedance | 350 Ohm |
Input signal gain | ±64dB |
Power consumption | 120VA |
propagation speed factor | 10-300m/μs |
Working conditions | temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg |
Volume and weight | Cable fault tester 430×380×220mm-10kg; Pulse coupler 430×380×220mm-10kg |
Panel introduction1 Display: 12.1-inch industrial-grade touch screen;
2 Communication: low-voltage pulse method pulse signal output interface, high-voltage flashover method sampler receiving signal input interface;
3 Grounding: safety grounding terminal;
4 Power indicator: Indicates the internal battery power, displayed in 4 grids;
5 USB-1: External wireless network card and USB communication device;
6 USB-2: External wireless network card and USB communication device;
7 Power switch: "I" position, use AC 220V power supply to supply power to the system;
The "II" gear uses the internal battery to power the system; when the "power socket" is connected to the AC 220V power supply, it also charges the battery at the same time;
"O" gear, turn off the system power;
8 Power socket: working power supply of the instrument, AC 220V connection port;
9 Fuse: the place where the fuse of the AC 220V power supply system is installed;
10 Self-check: transmit signals under multiple pulses;
11 On/Off: Turn on and off the working power of the industrial computer;
12 Amplitude: Adjust the amplitude knob when collecting waveforms to change the amplitude of the collected waveforms;
13 Indicator light: the indicator light reflecting the inspection method;
14 Displacement: Adjust the displacement knob when acquiring waveforms to change the baseline height of the acquired waveforms;
---------------------------------------------------------------------------------------------------------------------------------------------------------------------
High voltage surge generator XHHV535-4TDescription
The XHHV535-4T high voltage surge generator is currently the most user-friendly trolley-type DC impulse high-voltage equipment. It can be used for shock discharge in the detection of medium and low voltage cable faults. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.
Panel introduction
Technical parameters
Impact high voltage | 0~35Kv |
High voltage partial pressure | 2.5 level |
Built-in capacitor | 4μF |
Discharge power | 2450J |
Impact power | 2000W |
Output voltage polarity | negative polarity |
Impact time | about 5 seconds for automatic impact, arbitrary control time for manual impact |
Over current protection | 14A (more than 3 seconds) |
Volume(mm) | 534L×444W×805H |
Weight | not more than 120kg |
Power supply | AC220V±10%, 50Hz±2Hz(60Hz can be customized) |
Ambient temperature | -20~+60ºC |
Packing ListMore photos
---------------------------------------------------------------------------------------------------------------------------------------------------------------------
Welcome you contact us for more information~