Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv

Product Details
Customization: Available
After-sales Service: Warranty
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
  • Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Find Similar Products
  • Overview
  • XHGG502A2
  • XHLJ503C
  • XHHV535-2L
Overview

Basic Info.

Model NO.
502A2+503C+535-2L
Usage
Digital Cable Tester
Cable Type
Shielded
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
1000pieces/Year

Product Description

 

Underground cable fault locator set
XHGG502A2
XHLJ503C
XHHV535-2L

Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV
and below; calibrate the cable length; accurately detect the direction and depth of the cable buried.

Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv

 

                     XHGG502A2                                           XHLJ503C                                                 XHHV535-2L

XHGG502A2

Description
The cable fault tester adopts an industrial-grade 10.1-inch touch-integrated computer, a simple operating software interface, industrial-grade integrated circuits and devices, and a built-in large-capacity lithium-ion battery, which is stable, reliable, and easy to use.

This cable fault tester is a special instrument for measuring and analyzing the status and fault distance of power cables. This cable fault tester uses a combination of modern electronic technology and computer technology to achieve signal filtering, acquisition, data processing, graphic display, and graphic analysis. Cable speed measurement, cable length test, cable fault distance test.

This cable fault tester is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Network failure. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites", "DL/T 849.1-2019 General technical conditions for special testers for power equipment Part 1: Cable fault flash tester", "JJF1042-2020" "Calibration Specifications for Cable Fault Testers" standard requirements.
Work mode: TDR(low voltage pulse), High voltage flashover( ICE(Impulse current)/Decay)

Features
• 10.1-inch full-color TFT touch display;
• Embedded system, safe, stable and simple display and operation mode;
• With the function of testing cable wave speed, cable length and fault distance;
• Fully automatic continuous sampling, waveform capture at all times, timely and accurate.
• Equipped with automatic test range setting, automatic waveform analysis and display of test distance.
• Full English menu, two operation methods of touch and coded buttons, simple, fast and reliable.
• Equipped with testing technology of low-voltage pulse method, high-voltage flashover method, the waveform display is smooth and easy to interpret.
• The instrument has powerful data processing capabilities, making it convenient for users to manage and archive waveform files.
• Has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument in the order specified by Chinese naming for recall and observation at any time; it can store more than 8,000 records of low-voltage pulses and high-voltage flashover waveforms, and multiple pulses More than 250 waveform records can be recorded, and waveform files can be imported into computer software for management and analysis using USB communication.
• Ultra-high brightness, LED backlight brightness reaches 280nit, resolution 1024*600, convenient for environments exposed to direct sunlight in operation.

Technical specification
 

Sampling frequency 80MHz
Low voltage pulse amplitude 100V±15%
Ranging range 65km
Test range  300m/1km/5km/25km/65km
Pulse width 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS
Minimum resolution 0.1m
Test blind area 20m
Measurement error  ≤±(0.5%×L+1m), L is the cable length
Power supply mode charging AC110V~240V, 50Hz/60Hz
Volume and weight L358mm×W284mm×H168mm-4.7kg
Working conditions Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg


Packing list

Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv

XHLJ503C

Introduction
The cable fault location instrument uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.
 

  1. Technical indicators
1 Filter parameters All-pass: 100Hz~1600Hz.
Low pass: 100Hz~300Hz.
Qualcomm: 160Hz~1600Hz.
Bandpass: 200Hz~600Hz.
2 Channel gain 8 levels adjustable.
3 Magnetic channel gain 8 levels adjustable.
4 Output gain 16 levels (0~112db)
5 Output impedance 350Ω
6 Acoustomagnetic positioning accuracy  less than 0.2m.
7 Path identification accuracy  less than 0.5m.
8 Power supply 4*18650 standard lithium batteries.
9 Standby time more than 8 hours.
10 Volume 428L×350W×230H
11 Screen pixels 854-480
12 Brightness 800nit
13 Transmission speed unit 0-100ms
14 Accuracy 1ms
15 Sound bandwidth 100-1.6khz
16 Magnetic coil bandwidth 100-20kHZ
17 Both sound and magnetism are greater than 75db
18 Weight  6.5kg.
19 Ambient temperature -25~65ºC; Relative humidity: ≤90%.

Operation panel introduction
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;
2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;
3 Display: 5-inch touch display.
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv1 Sensor: Probe sensor connection port;
2 Charging: charger connection port;
3 Dedicated headphone jack.

Packing list

Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Picture the scene

 
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
XHHV535-2L

Description
The XHHV535-2L High voltage pulse generator is a tie-rod portable integrated device, which is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry. 

It integrates the energy storage capacitor, DC high voltage source, and discharge ball gap. The operation of this equipment is safe and reliable, with automatic protection functions of over-current, overvoltage and overheating, it can truly achieve the effect of not being damaged by impact, and it can also work normally with high voltage to ground. 

The XHHV535-2L High voltage pulse generator is equipped with a time relay, and the discharge time interval can be arbitrarily set within 0-100 seconds. When working, the high-voltage pulse output is uniform and controllable, high-voltage side voltage measurement, make the result real-time and accurate. Unique high-voltage measurement design, in the stop state, the voltmeter can indicate the capacitor voltage in real time. The user can observe the residual voltage while discharging, until the voltage value returns to zero, and finally make the discharge more thorough.
On-site photos
Panel introduction

Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kvPanel function description
1. Safety ground: The ground of the instrument shell must be reliably connected to the
ground in order to prevent the instrument shell from being electrified or electric shock to
personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to
prevent high-voltage leakage and discharge. Poor contact may cause failure to boost
the voltage, high voltage breakdown of the internal components of the instrument, and
safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a
high voltage and must be grounded reliably. It is used for sampling when the waveform
is sampled under the high-voltage flashover state of the cable fault tester. (WithoutHigh voltage surge generator
high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge
manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage
output is in the zero position. When the light is on, the start button is valid. If the start
button light is not on after turning on the power switch, turn the voltage adjustment knob
counterclockwise until the light is on. When the button light is on, press this button to
start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs,
press this button to cut off the high-voltage output, the high-voltage light goes out, and
the internal discharge ball stops working. When the stop key is on, it means there is
high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current
protection function has started; when it is popped up, it means that the instrument has
triggered the over-current protection.
8. Voltage adjustment: After turning on the device, you must first turn the knob
counterclockwise to the end, press the start button, and then adjust clockwise to
increase the output high voltage from small to large, and adjust counterclockwise to
reduce the output high voltage from large to small.
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns
off the system power.
10. The fuse holder: the place where the fuse of the AC 220V power supply system is
installed.
11. Power socket: the working power supply of the instrument, AC 220V connection
port.
12. Time setting: Set the discharge time interval.
13. Ammeter: indication of the current on the high voltage side.
14. Voltmeter: high voltage output voltage indicating kV meter.
15. High-voltage output (EMP): When impacting discharge, connect the high-voltage
output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage
output line

Technical parameters

Impact high voltage 0~32kV
High voltage partial pressure 2.5 level
Built-in capacitor 2μF
Discharge power 0-1024J
Output voltage polarity negative polarity
Impact power 250W@peak
Working mode Selectable or adjustable impulse rate and Single shot
Minimum Output current in DC mode 7.5mA at 32kV
Length of test cable The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long.
Over temperature protection 65ºC
Over current protection 8mA (more than 3 seconds)
Volume(mm) 540L×300W×450H
Weight not more than 25kg
Power supply AC220V±15%, 50Hz±2Hz(60Hz) 
Ambient temperature -20~+60ºC
Cable length High voltage output cable - 2 meters, ground wires - 2.5 meters, power cable - 1.8 meters.



Packing List
Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv
Picture the scene

Manufacturer 32kv Surge Generator Cable Fault Detector Portable Cable Fault Locator 11kv

If you have any needs, please feel free to contact us!





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier