• Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
  • Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
  • Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
  • Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
  • Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
  • Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator

Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator

After-sales Service: Warranty Certificate
Warranty: 12 Months
Usage: Digital Cable Tester
Power: Electricity
Certification: CE, ISO
Customized: Customized
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XHHV535-2TS
Color
Black
Transport Package
Wooden Case
Specification
534× 444× 805mm
Trademark
XZH TEST
Origin
China
HS Code
8543201000
Production Capacity
2000PCS/Year

Product Description

Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
 

High voltage surge generator XHHV535-2TS/XHHV535-4TS 
Surge voltage generators enable accurate location of high resistance, low resistance and intermittent faults on high, medium and low voltage cables.
Output voltage is continuously adjustable in the ranges 0 - 8 kV, 0 - 16 kV and 0 - 32 kV.
Discharging of high voltage capacitors into the faulty cable can be made continuously or cyclically via surge switch. When the instrument is switched off, the connected cables and the internal surge capacitors are automatically discharged separately from each other.


Features
High surge voltage up to 32 kV
Three voltage ranges and capacitance switching function
3 range kV-meter direct reading
High surge energy in each voltage range
Automatic discharging device
With zero start protection function, safe and reliable
3 selectable operating programmes: single pulse ,DC , Cycle pulse
  

Overcurrent protection
Internally installed high-precision test cable fault sampling waveform module
The discharge time can be selected from two modes: timing and manual.


Technical data
  XHHV535-2TS XHHV535-4TS
Mains supply AC220V ±10% AC220V ±10%
Option 110-120V  with external auto transformer or isolating transformer 110-120V with external auto transformer or isolating transformer
Mains frequency 50Hz/60Hz ±2% 50Hz/60Hz ±2%
Max. Power consumption(at short circuit) 2000VA 2000VA
Max. output voltage 32kV 32kV
Output voltage range 0-8kV
0-16kV
0-32kV
0-8kV
0-16kV
0-32kV
Max. surge energy 2048J@each voltage level 2048J@each voltage level
Impulse frequency 1 imp./7s,Can be set manually 1 imp./7s,Can be set manually
Discharge Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device
Burn current(DC output current) Fault conditioning (burning) with current up to
60 mA @ 32 kV,When the voltage is low, the current will be larger
Fault conditioning (burning) with current up to
60 mA @ 32 kV,When the voltage is low, the current will be larger
Precision of the KV meter 1.5 1.5
operating temperature range -25~+65ºC -25~+65ºC
Over current protection 9A (greater than 5S) low voltage side 9A (greater than 5S) low voltage side
Over temperature protection 105ºC 105ºC
Safety system Over-voltage 
Over-current
Overheating protection
Automatic discharge after operation
Over-voltage 
Over-current
Overheating protection
Automatic discharge after operation
Protection rating Not lower than IP54 Not lower than IP54
Net weight(kg) Not more than 130kg Not more than 130kg
Dimension(mm) 740520880H 740520880H

Delivery includes
Surge wave generator without accessories
Mains connection cable(1pcs-3m)
HV connection cable(1pcs-5m)
Ground line(1set-5m)
Fuse(8A)-3pcs
Discharge rod-(1pcs-50kV)


Option: For extension HV connection cable, ground line, mains connection cable, we can customize lengths of 15m, 20m, 25m, 30m, 50m, etc.

XHHV535-2TS and XHHV535-4TS optional, welcome you contact us for more information and service!~
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
 


 
Panel function description
 
1. Ammeter: Show the current of low voltage side
 
2. Voltmeter:High-voltage output voltage indication kV meter, divided into 8kV,  16kV, 32kV combined with voltage level switch readings.
 
3. Power:After turning on the power switch, the indicator light is on, indicating  that the AC220V is normal.
 
4. High-voltage light(HV):On means there is high voltage output, and off  means there is no high voltage output.
 
5. Zero light(Zero):Indicates that the pressure regulating knob is in the zero  state, and the start key is effective only when it is on.
 
6. Signal:Connect the device and the cable fault tester with the double Q wire to  collect the flashover waveform, which is valid only for high-voltage flashover.
 
7. Power switch(NO/OFF): AC 220V 50Hz power input socket. Fuse holder and  main power switch of device. 8A Fuse.
 
8. Single:The indicator will light when choose single discharge.
 
9. Mode selete: DC,Single,Cycle.  DC model is to start withstand voltage test( hipot test) to cable.  Single model is discharge by hand controlling. Press it and then adjust High voltage  knob to control discharge time by hand.
 
Cyclic model is discharged automatically which means select this function to rise up  voltage after start high voltage ,this device will be automatic trigger impulse  discharge, time is about 5 seconds.
 
10. Start:In the zero position, press the start button, and the high voltage starts at this time, and the high voltage light is on. In the non-zero state, the high-voltage  lamp does not light up when starting.
 
11. Stop: When the test is completed or an abnormality occurs, press this key to  cut off the high voltage output. At this time, the remaining high voltage in the test  stop will also be automatically discharged.
 
12. Voltage control:When this knob is in the zero position, the zero position  light is on, and the high voltage can be started. After the high pressure is started,  the pressure can be increased through the pressure regulating knob.
 
13. Voltage select: This key has three voltage level modes, 8kV, 16kV, and  32kV. Please rotate it to a suitable position before turning on the machine. Lift,  rotate, press.

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Application

Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator


Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
 

Packaging: Wooden case filled with foam 

Shipping: by Air, Sea, Express, etc.

Shipping time: 7-15 days if it's in stock. 


Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge GeneratorPortable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator
 


Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator

Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator


Portable Fault Positioning Test Equipment High Voltage 8/16/32kv Surge Generator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now