Basic Info.
- Model NO.
- XHHV535-4TS+XHGG502A+XHDD503C+XHGX507C
- Test Mode
- Instant Test
- Usage
- Audio Cable Tester, Coaxial Cable Tester
- Test Region
- Forming Cable
- Cable Type
- Shielded
- Power
- Electricity
- Certification
- CE, ISO
- Customized
- Customized
- Transport Package
- Wooden
- Trademark
- XZH TEST
- Production Capacity
- 1000
Product Description
(XHHV535-4TS+XHGG502A+XHDD503C+XHGX507C)
1.whole system
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; accurately detect the direction and depth of the cable buried
| Product name | Model | Main function |
| High voltage pulse generator | XHHV535-4TS | ★ impulse high voltage: 0 ~ 32kv, 0 ~ 16Kv and 0 ~ 8Kv three gear regulation ★ Short circuit current: 0-60mA ★ high voltage partial voltage: voltage accuracy level 2.5 ★ built in capacitor: 4 μ F/32kV,16 μ F/16kV,64 μ F / 8KV three gear regulation ★ discharge power: 2048J ★ Output voltage polarity: negative polarity ★ impact time: automatic impact for about 5 seconds, manual impact for any control time ★ Overcurrent protection: 9A (greater than 5s) low-voltage side ★ impact power: 2000W ★ weight: about 130kg |
| Cable fault pre locator | XHGG502A | ★ Display: 10.1-inch touch screen,Windows system; ★ Function: Test cable wave speed, cable length and fault distance; Automatic testing range setting, automatic waveform analysis to display testing distance; Powerful data processing and massive test waveform storage. ★Testing methods: Low voltage pulse method, high voltage flashover method, ARC multiple pulse method ★Power supply : Equipped with a 5200mAH lithium battery for power supply; Charging AC110V~240V, 50Hz/60Hz ★Sampling frequency: 1MHz~400MHz; ★Low voltage pulse amplitude: 300V ± 15%; ★Distance measurement range: ≥ 120km; ★ Pulse width: 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS; ★ Minimum resolution: 0.07m; ★ Test blind spot: ≤ 10m; |
| Cable fault pinpointer | XHDD503C | By Acoustic-magnetic synchronization method to accurately locate the fault point of the cable and detect the path , with powerful background noise reduction(BNR) and compass indication functions |
| underground cable pipeline locator (cable route tracer) |
XHGX507C | ★ Function: pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding ★Scope of application: detection and patrol of various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline detection of power supply and other departments, ★ Frequency range: Active detection frequency: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz RF passive detection frequency band: center frequency is divided into 32.7kHz, 65.6kHz, 81.9kHz, 197kHz ★ Pipeline measurement depth: 0-20m ★Test method: DC method, induction method, coupling method |
1) Single chip controled computer, keyboard operation mode, strong anti-interference ability;
2)System functions: fault distance measurement, fault pinpoint location, propagation speed test, cable path search, buried depth detection;
3)Test methods: low-voltage pulse, flashover method, audio method, acousto-magnetic synchronization method, valley method, peak method, electromagnetic induction method, etc.;
4)Test range: test distance: >120km, detection depth: 2-5m;
5)Measurement accuracy: Rough measurement error: ±10m (absolute value) or 1% (relative value), fine measurement error: ±0.2m (fixed point, path, depth);
6)Sampling frequency: 1-400MHz, minimum resolution 0.5m (100m/us)
7)Sampling method: automatic continuous sampling, never miss any discharge waveform.
8)Low voltage pulse: Width: Adaptive Amplitude: 400Vpp
9)Output power: path power: 100W
10)Shock high voltage: three voltage 8/16/32kV adjustable
11)Short circuit current:0~320mA
12)Burn through power:0~2048J
high voltage pulse generator -----XHHV535-4TS
| high voltage surge generator XHHV535-4TS | Surge voltage levels and adjustment ranges |
Level 1 : 0-8KV Level 2: 0-16KV Level 3: 0-32KV |
| High voltage divider: | Voltage Accuracy 1.5 grade | |
| Inside capacitor: | 4μF/32kV,16μF/16kV, 64μF/8kV | |
| Surge energy: | 2048J | |
| Surge power: | 2KVA | |
| Operating mode | Single trigger/cycle/DC | |
| Impact time | about 5 seconds for automatic impact, arbitrary control time for manual impact | |
| Safe protection | With zero start protection function, safe and reliable | |
| Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
| DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A |
|
| Burn current | Up to 160mA | |
| Connecting cable | High voltage output cable: 5m, Power supply cable: 1.8m, Protective earthing cable: 3m | |
| Safety | Overvoltage, Over-current, Overheating protection. Automatic discharge after operation. |
|
| Protection rating | Not lower than IP54 | |
| GW | 130kg |
Cable fault prelocator----XHGG502A
| ARC Cable Fault pre-locator XHGG502A |
Pre-location method | LV TDR (low voltage pulse method/ impulse reflection method) |
| HV TDR(high voltage flashover method /single impulse method ) | ||
| ARC (multiple impulse arc reflection method) | ||
| ICE (impulse current method) DECAY (voltage decay method) |
||
| Automatically test velocity speed | ||
| Display | 10.1 inch industrial-grade computer control, touch operation mode | |
| System | Windows operating, automatic generate test reports. | |
| Function | Speed, resistance, distance measurement | |
| Sampling frequency | 1MHz~400MHz | |
| Low voltage pulse amplitude | 300V±15% | |
| Pulse width | 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS; | |
| Measuring distance | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km/120km; | |
| Reading resolution | 0.07m; | |
| Test accuracy | ≤±(0.5%×L+1m), L is the cable length; | |
| Cable length choice | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km | |
| Pulse coupler withstand voltage | 35kV DC | |
| Test blind zone | ≤10m | |
| Data storage | Stores more than 8,000 records of low-voltage pulse and high-voltage flashover waveforms, and more than 250 records of multiple pulse waveforms. | |
| Power supply | charging AC110V~240V, 50Hz/60Hz; Built-in 5200mAH lithium battery power supply; charging time is about 2 hours, working time is more than 5 hours; |
|
| Communication | With standard USB interface | |
| Working conditions | Temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg; | |
| Volume and weight | Cable fault tester L358mm×W284mm×H168mm-4.7kg; Pulse coupler L430mm×W380mm×H220mm-10kg. |
Cable fault pinpointer ------XHDD503C
| 1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
| 2 | Channel gain | 8 levels adjustable. |
| 3 | Magnetic channel gain | 8 levels adjustable. |
| 4 | Output gain | 16 levels (0~112db) |
| 5 | Output impedance | 350Ω |
| 6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
| 7 | Path identification accuracy | less than 0.5m. |
| 8 | Power supply | 4*18650 standard lithium batteries. |
| 9 | Standby time | more than 8 hours. |
| 10 | Volume | 428L×350W×230H |
| 11 | Weight | 6.5kg. |
| 12 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
underground cable pipeline locator ------XHGX507C
Cable route tracer XHGX507C has multiple functions such as cable pipeline path & depth detection , cable identification, fault finding, etc.it consists of a transmitter, a transmitting current clamp, a receiver, a receiving flexible current clamp, a connecting test line, an A-frame (optional), etc.
It uses a variety of filtering technologies and has anti-interference capabilities. It can be used for path detection ,depth accurately location and measurement,pipeline census and depth measurement of metal pipelines and underground cables in non-excavation conditions.
It is suitable for the detection and patrol of various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, power supply and other departments. It is one of the necessary instruments for pipeline maintenance units.
| Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding |
| Power supply | 8.4V large capacity rechargeable lithium battery |
| Input method | Built-in receiving coil, flexible caliper, A-frame (optional function) |
| Receiving frequency | Active detection frequencies: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz RF passive detection frequency band: center frequencies are 32.7kHz, 65.6kHz, 81.9kHz, 197kHz |
| Pipeline detection mode | Broad peak method, narrow peak method, valley method |
| Pipeline detection Detection range |
Direct connection method: Generally, the cable length can reach 0~20 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth. Coupling method: Generally, the cable length can reach 0~10 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth. Induction method: suitable for cables buried less than 2m deep |
| measurement depth | 0-20m |
| Cable identification Detection range |
Direct connection method: can identify signals with loop resistance of 0Ω~8kΩ (usually can reach cable length of 0~20 kilometers, mainly determined by ground resistance and cable resistance) Coupling method: can identify signals with loop resistance of 0Ω~1kΩ; (generally, the cable length can reach 0~6 kilometers, mainly determined by the ground resistance and cable resistance) |
| liquid crystal | 4.3-inch LCD color screen (high brightness screen), visible in sunlight |
| Size | About 350mm (length) × 155mm (width) × 700mm (height) |
| Weight | About 2kg |
| Coil inner diameter | φ200mm (larger diameter can be customized as needed) |
| Working temperature and humidity | -10ºC~40ºC; below 80%Rh |
| Suitable for safety regulations | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2 |
Transmitter
| Function | Multiple frequency signal transmission modes |
| power supply | 10.8V large capacity rechargeable lithium battery |
| Output method | Direct connection method, coupling method, induction method |
| Output frequency | 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz |
| Output Mode | Automatic identification, automatic identification according to different accessories |
| Output Power | 15W max, 9 levels adjustable |
| impedance | Fully automatic real-time impedance matching and protection function |
| Direct output voltage | 150Vpp max |
| Circuit Protection | With overload and short circuit protection |
| liquid crystal | 5-inch LCD color screen |
| Touch | Yes, capacitive touch |
| Instrument size | About 320mm (length) × 275mm (width) × 145mm (height) |
| quality | Transmitter weight: about 3.85kg; Transmitter clamp weight: about 1.18kg |
| charger | DC 11.1V 3A |
| Launching clamp size | Length, width and thickness: 297mm×194mm×39mm |
| Inner diameter of firing clamp | φ125mm |
| Transmitter cable length | 3m |
| Test line | Red test line 3m, black test line 3m |
| Connection interface | USB port, DC port, aviation socket |
| Stress resistance | The transmitter adopts an integrated special tool box design, and the box can withstand a pressure of about 200kg. |
| Pressure resistance | AC 3700V/rms (between the top and bottom of the instrument box) |
| Electromagnetic properties | IEC61326(EMC) |
| Suitable for safety regulations | IEC61010-1 (CAT 300V, CAT IV 150V, pollution degree 2) |




Send your message to this supplier
People who viewed this also viewed
-
US$1,300.00-1,390.00 / Piece
-
US$13,500.00-14,500.00 / Set
-
US$1,000.00-3,000.00 / Piece
-
US$14,500.00-15,500.00 / Set
-
US$4,800.00-5,000.00 / Set
-
US$200.00-2,080.00 / Piece
-
China Factory Underground Power Cable Fault Pre-Locator Detect Damaged Cable Distance Easy OperationUS$900.00-950.00 / Piece
-
US$1,050.00-1,150.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Cable diagnosis and fault location system
- Cable fault locator set
- 2025 Xzh Test Underground Cable Fault Locator Kit – Comprehensive Testing & Troubleshooting