Xhgx507b Cable Fault Comprehensive Tester with Path Indication

Product Details
Customization: Available
After-sales Service: Warranty
Warranty: 12 Month
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
  • Xhgx507b Cable Fault Comprehensive Tester with Path Indication
Find Similar Products
  • Overview
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
XHGX507B
Usage
Digital Cable Tester
Power
Electricity
Certification
CE
Customized
Customized
Color
Blue
Working Temperature
-10°c——+55°c
Battery Model
Rechargeable Battery
Battery Indication
Graphic Display
Battery Life
Continuous Working >8 Hours
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi&an
Production Capacity
1000

Product Description

XHGX507B is a multi-functional underground metal pipe detector. It consists of a signal transmitter and a receiver. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. With a variety of optional accessories, it can Unique identification, as well as the location of pipeline insulation damage and cable low resistance and disconnection faults.

Product Parameters

1. Receiver
Xhgx507b Cable Fault Comprehensive Tester with Path Indication

Input method built-in receiving coil, identification clamp (optional), A-frame for troubleshooting (optional)
Detection frequency 256Hz, 286Hz, 320Hz, 380Hz, 460Hz, 640Hz, 1280Hz, 1860Hz, 512Hz, 570Hz, 577Hz, 640Hz, 760Hz, 870Hz, 920Hz, 940Hz, 8KHz, 9KHz, 33KHz, 65KHz, 83KHz, 131KHz, 200kHz,
Power frequency passive detection frequency: 50Hz/60Hz, radio passive detection frequency, low frequency
Pipeline detection mode wide peak method, narrow peak method, sound valley method, peak valley method
Cable identification mode clamp (optional) intelligent identification and current measurement
Machine interface 480×272 dot matrix liquid crystal display
Built-in battery 4pcs 18650 lithium-ion batteries, nominal 4.2V, 8.2Ah.
The positioning depth 0-6m; when the depth is measured, the depth of the pipeline under test is 0-3m (accuracy ±5%), and the depth of the pipeline under test is 3-12m (accuracy ±10%)


2. Transmitter
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
 

Input method built-in receiving coil, identification clamp (optional), A-frame for troubleshooting (optional)
Detection frequency 256Hz, 286Hz, 320Hz, 380Hz, 460Hz, 640Hz, 1280Hz, 1860Hz, 512Hz, 570Hz, 577Hz, 640Hz, 760Hz, 870Hz, 920Hz, 940Hz, 8KHz, 9KHz, 33KHz, 65KHz, 83KHz, 131KHz, 200kHz,
Power frequency passive detection frequency: 50Hz/60Hz, radio passive detection frequency, low frequency
Pipeline detection mode wide peak method, narrow peak method, sound valley method, peak valley method
Cable identification mode clamp (optional) intelligent identification and current measurement
Machine interface 480×272 dot matrix liquid crystal display
Built-in battery 4pcs 18650 lithium-ion batteries, nominal 4.2V, 8.2Ah.
The positioning depth 0-6m; when the depth is measured, the depth of the pipeline under test is 0-3m (accuracy ±5%), and the depth of the pipeline under test is 3-12m (accuracy ±10%)



3.Others:

1. Volume: transmitter 320×240×90mm, receiver 670×128×310mm.
2. Mass: transmitter 1.9kg, receiver 1.4kg.
3. Charger: input AC100~240V, 50/60Hz, output DC4.2V-1A, output DC12.6V-1A.
4. Conditions of use: Temperature: -20ºC-70ºC, humidity 5-90%RH, altitude <4500m.

Features

lCompass and direction display: visually display the pipeline direction and left and right directions.
lCurrent direction measurement, eliminating line interference (partial frequencies).
lDepth and current measurement.
lFully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving frequency band, strong anti-interference ability, and can fully suppress power frequency and harmonic interference from nearby running cables and pipelines.
lRunning cable detection: High-performance transmitting caliper, coupling the output signal to the running cable to the greatest extent.
lCable/pipeline identification: The flexible caliper (optional accessory) is easy to use and clearly gives the identification results; it can be used when it is inconvenient to use the caliper.
lGround fault finding: Use the A-frame (optional accessory) to locate the damaged point of the pipeline's insulation against the ground, and the arrow indicates the direction of the fault point.
lMultiple detection frequencies: active detection and passive detection.
lThe transmitter has multiple signal output modes: direct output, caliper coupling, and induction.
lTransmitter digital power amplifier power output, fully automatic impedance matching, fully automatic protection.
lBuilt-in large-capacity lithium-ion battery, automatic shutdown when under voltage, automatic shutdown (receiver) if no operation for a long time.
lThe casing is beautiful, sturdy, lightweight and portable.


Working method

There are three methods for the transmitter to transmit the signal to the pipeline: direct connection, clamp coupling and induction.
 

Xhgx507b Cable Fault Comprehensive Tester with Path Indication
The direct connection method is to connect the output line of the transmitter directly to the metal pipeline, and inject the signal directly. The direct connection method is suitable for: water pipelines, gas pipelines, communication cables, power cables, cathodic protection pipeline test points or other access points, and continuous metal structures with long-term characteristics.
 
The clamp coupling method is suitable for the case where the pipeline is exposed, but cannot (or is not allowed) to touch its metal parts, and the pipeline is grounded at both ends (especially suitable for power cables).
 
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
When the pipeline has no exposed point, the radiation induction method needs to be used; before the ground excavation, the induction method is mainly used when it is necessary to detect whether there is a pipeline underground. The advantage of the induction method is that it is easy to use, does not need wiring, and does not have any form of electrical connection with the pipeline. It is especially suitable for pipeline detection without exposed points, and it is also a main method for regional pipeline detection. The disadvantage is that the induced current of the pipeline is smaller than that of the direct connection method and the caliper method, especially when the pipeline depth is large, the effect is poor, and it is suitable for pipelines with a depth of less than 2m; signals can be induced for all pipelines within a certain range, which will affect the specific pipeline, make the recognition difficult.
 

 

Certifications

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

Packaging & Shipping
PACKING LIST
Standard accessories
Serial number Name quantity
1
Receiver 1
2
Transmitter 1
3
Transmitter direct output cable 1
4
Coupling clamp cable 1
5
Ground wire 1
6
Charger 2
7
Ground bridge 1
8
Coupling clamp 1
Optional accessories (must be specially specified when ordering, not specified by default)
Serial number Name Drawings and instructions
1 Identify connecting cables
 
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
 
(Blue 9-pin plug)
2 A bracket connection cable
 
 
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
 
(Blue 9-pin plug)
 
3 Identifying forceps
 
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
 
4 Identifying forceps
 
Xhgx507b Cable Fault Comprehensive Tester with Path Indication
 

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

Company Profile

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

FAQ

Xhgx507b Cable Fault Comprehensive Tester with Path Indication

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier