60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
  • 60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
XHZG series
Power
Electricity
Certification
ISO
Customized
Customized
Transport Package
Exported Wooden Case
Trademark
XZH TEST
Origin
China
Production Capacity
2000PCS/Year

Product Description

 

Product Description

Scope of application
The DC high-voltage tester is mainly applicable to the DC withstand voltage test or DC leakage current test of zinc oxide arrester, power cable, transformer, circuit breaker, generator and other high-voltage electrical equipment by the power department of electric power department, industry and mining, metallurgy, iron and steel and other enterprises.

Boost mode: manual boost

 

Features

 


XHZG series DC hipot tester Using aipwm technology, the inaccurate linearity of PWM technology is adjusted, and the accuracy of the instrument is greatly improved. The AI technology screen is used to set overvoltage protection and overcurrent protection, which replaces the problem that the digital dial switch can only set the voltage value, but can not set the current value and voltage drift. 0.75udc1ma function button, convenient for zinc oxide arrester test, accuracy ≤ 0.5%. The timing function under any voltage and current, total time T1 and sectional timing T2 are added. The instrument adds the functions of perpetual calendar and time.

·The case adopts portable case, which is easy to carry.
·Using aipwm technology, the inaccurate linearity of PWM is adjusted, and the accuracy is greatly improved. Ripple coefficient ≤ 1%.
·AI zinc oxide arrester and oil immersed transformer measurement function. The experimental report can be saved directly, and the accuracy is ≤ 0.5%. Udc10.75ma manual hold.
·AI technology is used to set overvoltage protection and overcurrent protection, which replaces the problem that the digital dial switch can only set the voltage value, but can not set the current value and voltage drift. Error ≤ 1%
·Full range smooth voltage regulation, voltage regulation accuracy ≤ 0.5%, stability ≤ 0.5%, voltage and current error ≤ 0.5% ± 1 word
·With total time T1 and sectional timing T2, and timing function under any voltage and current.
·The instrument adds the functions of perpetual calendar and time.

60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator



ENGLISH VERSION AVAILABLE
WELCOME YOU CONTACT US FOR MORE INFORMATION

60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator



 

Product Parameters

   Specifications

technical parameter
 
60/2/3 120/2/3 60/5 120/5
Output voltage (kV) 60 120 60 120
Output current  (mA) 2/3 2/3 5 5
Output power
(W)
120/180 240/360 300 600
Charging current  (mA) 3/4.5 3/4.5 7.5 7.5
Weight of control box
(kg)
11.6 13 16 17.6
Weight of pressure doubling cylinder (kg) 2.3 3.6 5.8 6.3
Specification of pressure doubling

cylinder (mm)
Ф90
340
Ф90
470
Ф110
480
Ф110
530
Voltage measurement error ± 0.5% (full scale) ± 1 word
Current measurement error ± 0.5% (full scale) ± 1 word
Overvoltage setting error AI technology sets overvoltage protection and overcurrent protection error≤0.5%
0.75 switching error High precision 0.75udc-1ma one touch button (precision ≤ 0.5%)
Most suitable for zinc oxide arrester test
Ripple coefficient ≤0.5%
operation mode Intermittent use: rated load for 30 minutes
1.1 times of rated voltage: 10 minutes
work environment temperature:-10ºC~+40ºC
Relative humidity: no more than 85% at room temperature of 25 ºC (no condensation)
Altitude: below 1500 meters
Capacitive load The capacitance of the tested object is unlimited
Structural features Electrical insulation double pressure cylinder
Air insulation, no leakage
 

 

 

 



60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator

 

 

 

Packaging: The product is packed by aluminum box internally,then put into wooden case filled with foam 

Shipping: by Air, Sea, Express, etc.

Shipping time: 7-15 days if it's in stock. 

60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator
60kv 120kv 200kv 300kv DC Hipot Tester DC High Voltage Generator

 

FAQ

 

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: What is your terms of payment ?

A: Payment<=1000USD, 100% in advance. 


If you have other questions, pls send us an inquiry below:

XI'AN XU&HUI ELECTROMECHANICAL TECHNOLOGY CO.,LTD

Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an
 
 

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier