Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester

Product Details
Customization: Available
After-sales Service: Warranty
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
  • Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
XHDP series
Usage
Coaxial Cable Tester, Digital Cable Tester, Vlf AC Hipot Tester
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Model Number
Xhdp Series
Output Voltage
30kv/50kv/60kv/80kv/90kv Optional
Output Frequency
0.1Hz, 0.05Hz,0.02Hz Automatic Frequency Conversio
Accuracy
3%
Power Supply for Work
50/60Hz, AC220V±10%
Certificate
ISO, CE
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi′ an
Production Capacity
1000

Product Description

Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterOutput Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Product Description

This XHDP Series VLF AC cable hipot tester adopts digital frequency conversion technology, single-chip microcomputer control,voltage boost, buck, measurement, protection completely automatic. Due to the full electronic, so small size and light weight, the use of large screen color touch display, clear and intuitive, simple operation, display output waveform. The design index conforms to the national standard of "General Technical Conditions of Ultra-low frequency high voltage generator". The main features are as follows:
Detailed Photos
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterOutput Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Product Parameters
Specification
Rated voltage Carrying capacity Application range Power supply Fuse Remark
30kV(peak) Automatic frequency change:0.1Hz-0.01Hz
On-load capacity:<=10µF
Used for voltage test of cables and motors within 10KV 8A Customizable touch screen with USB port
40kV(peak) Automatic frequency change:0.1Hz-0.01Hz
On-load capacity:<=10µF
Used for voltage test of cables and motors within 10KV 8A  
50kV(peak) Automatic change frequency: 0.1Hz-0.01Hz
Load capacity: <=6µF
Used for voltage test of cables and motors within 15KV 10A Customizable touch screen with USB port
60kV(peak) Automatic change frequency: 0.1Hz-0.01Hz
Load capacity: <=5µF
Used for voltage test of cables and motors within 25KV 20A Can be customized with dielectric loss tester
80kV(peak) Automatic change frequency: 0.1Hz-0.01Hz
Carrying capacity:
<=6µF(within 50kV),
<=4µF(above 50kV)
Used for voltage resistance test of cables and motors within 35KV 30A Customizable touch screen with USB port
customized with dielectric loss tester

1. Output rated voltage: see Specification
2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
3. Load capacity: 0.1Hz maximum 1.1µF
0.05Hz maximum 2.2µF
0.02Hz maximum 5.5µF
4. Measurement accuracy: 3%
5. Voltage positive and negative peak error: ≤3%
6. Voltage waveform distortion: ≤5%
7. Use conditions: indoor and outdoor; temperature: -10ºC∽+40ºC; humidity: ≤85%RH
8. Power fuse: see Specification
9. Power supply: frequency 50Hz, voltage 220V±5%.• Communication interface: RS232;
 • Power supply mode: charging AC 220V±10%, 50Hz/60Hz; built-in 5200mAH lithium battery power supply;


Technical parameter

1.Ultra-low frequency with rated voltage ≤60kV adopts a single-unit structure (one booster); ultra-low frequency above 60kV adopts a series structure (two boosters in series), which greatly reduces the overall weight and enhances the load capacity. The two boosters can be used separately to achieve multiple uses of one machine.
 
2.Current and voltage data are directly sampled from the high-voltage side, and the data is accurate.
 
3.Intelligent comprehensive protection function: There is no need to set the current and voltage protection values. The instrument calculates the overvoltage and overcurrent protection values according to the test capacity and test voltage value, and can protect against voltage and current mutations, so as to capture the discharge situation in time. The protection action time is less than 20ms.

4.150kV high-voltage incoming line output, safe and reliable.

5. Due to the use of closed-loop negative feedback control circuit, there is no capacity increase effect on the output.


Main structure of ultra-low frequency high voltage power supply(VLF hipot tester)

For the VLF hipot tester with a rated voltage below 50kv, a booster is used, which is called the single-coupled ultra-low frequency, and its structure and components are described in the following figure:
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
For VLF hipot tester with rated voltage above 50kv, two boosters are used in series, which is called series ultra-low frequency, and its structure and components are described in the following figure:

Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Connection method for ultra-low frequency withstand voltage test

(1) The connection method of ultra-low frequency voltage withstand test when the two-stage booster is connected in series is as follows:
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester(2)Below 50kV single-link ultra-low frequency voltage test connection mode is as follows:

Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterTest interface reference
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
The following photos are the physical pictures of the 50kV VLF hipot tester

Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterOutput Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Packaging & Shipping

 

Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester
Output Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterOutput Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot TesterOutput Frequency 0.1Hz/0.05Hz/0.02Hz Customizable 30-80kv Vlf AC Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier