• China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
  • China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
  • China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
  • China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
  • China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
  • China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding

China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding

After-sales Service: Warranty Certificate
Warranty: Warranty Certificate
Transport Package: Wooden
Trademark: XZH TEST
Origin: China Xi′an
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XHTX206
HS Code
854320100
Production Capacity
100 Pieces /Year

Product Description

 

XHTX206Transformer comprehensive characteristic tester

 

China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
Product description

The XHTX206 transformer comprehensive characteristic tester is a new generation of innovative CT and PT test instruments developed after theoretical research, which is based on the traditional volt-ampere characteristic variable ratio polarity comprehensive tester of voltage regulator, booster and current booster, and extensively listened to users' opinions and conducted extensive market research and in-depth research. The device adopts high-performance DSP and FPGA, advanced manufacturing technology to ensure stable and reliable product performance, complete functions, high degree of automation, high test efficiency, and is at the leading level in China. It is a professional testing instrument for transformers in the power industry.

 

Main features

1. Full function, which not only satisfies the excitation characteristics (ie volt-ampere characteristics), turns ratio, polarity, secondary winding resistance, secondary load, ratio difference of various types of CT (eg protection, metering, TP) Angle and other test requirements, can also be used for various types of PT electromagnetic unit excitation characteristics, turns ratio, polarity, secondary winding resistance, ratio difference and other tests.

2. On-site verification of current transformers does not require standard current transformers, current regulators, load boxes, voltage regulation control boxes and high-current wires. It uses extremely simple test wiring and operation to achieve current transformer verification, which greatly reduces the work. The strength and work efficiency are improved, and is facilitatedthe on-site verification of the transformer.

3. It can accurately measure the turns ratio and angular difference, the maximum allowable error of the difference is ±0.1%, and the maximum allowable error of the angular difference is ±5min. It can carry out the field test of the 0.2S class current transformer, and the ratio measurement range is 1~40000.With the special booster of our company, it can output 180A current, which is convenient for on-site flow test.

4. Test CT/PT volt-ampere characteristic curve and 10% error curve based on advanced frequency conversion method, output AC voltage of only 180V and AC current of 12Arms (36A peak), but can cope with CT test with inflection point up to 60KV.

5. Automatically give Inflection point voltage/current, 10% (5%) error curve, accuracy limit coefficient (ALF), instrument security factor (FS), quadratic time constant (Ts), remanence coefficient (Kr), saturation and unsaturated CT/ PT parameters.

6. Test to meet GB1208 (IEC60044-1), GB16847 (IEC60044-6), GB1207 and other types of transformer standards, and automatically select which standard according to the type and level of transformers for testing.

7. The test is simple and convenient, one-button CT straight resistance, excitation, turns ratio and polarity test. TheCT and other tests can be done only use the same wiring, except the load test.

8. Chinese/English dynamic graphic interface, can complete the wiring, set parameters even no need to read the manual: dynamic display parameter setting, automatically display its related parameters according to the currently selected test items; dynamic display help wiring diagram, the corresponding wiring diagram is displayedaccording to the currently selected test items.

9.5.7-inch graphic transflective LCD, clear to see even in the sun.

10. It is operated by rotating optical mouse, which is easy to operate, fast and convenient, and easy to learn.

11. The panel comes with a printer that automatically prints the test report.

12. The device can store 1000 sets of test data, and will not lose enen when the power is off.

 

Main Technical Parameters

Application

CT, PT

Output

0~180Vrms,12Arms,36A(peak)

Voltage test accurancy

±0.2%

CT Turns ratio test

Range

1~40000

Accuracy

1~2000, Accuracy<0.1%

2000~5000, Accuracy<0.2%

5000~35000, Accuracy<0.5%

PT Turns ratio test

Range

1~35000

Accuracy

1~2000, Accuracy<0.1%

2000~5000, Accuracy<0.2%

5000~35000, Accuracy<0.5%

Phase test

Accuracy

±5min

Resolution

0.5min

Secondary winding resistance test

Range

0~60

Accuracy

<0.52

AC load test

Range

0~1000VA

Accuracy

<0.50.02VA

Input power supply voltage

AC220V±10%,50Hz

Working environment

Temperature: -10οC~50οC

Humidity: 90%

Size and weight

Size: 365×29153mm  

Weight: <10kg

                           Current riser

Application

Flow current test

Input

0~180VAC

Current output

0~180A Accurancy<0.2%

Working environment

Temperature: -10οC~50οC

Humidity: 90%

Size and weight

Size: 2015170mm      

Weight<5kg

 

 

China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding
 

China Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary WindingChina Factory Supplier Transformer CT/PT Analyzer Excitation Characteristics Ratio Polarity Secondary Winding













 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now