XZH TEST Underground cable fault locator set
Cable fault location system
XHGG502+XHDD503+XHGX507+XHHV535-4TS
Accurately and quickly detect the main insulation failure of power cables with voltage
Product name | Model No. | Qty.(unit) |
cable fault pre locator | XHGG502 | 1 |
cable fault pinpointer | XHDD503 | 1 |
cable pipeline locator | XHGX507 | 1 |
high voltage pulse generator | XHHV535-4TS | 1 |
1) Industrial computer control, touch operation mode, strong anti-interference ability;
XHGG502 ARC Cable fault pre locator
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; roughly test cable fault distance
Cable fault pre-locator | XHGG502: for cable fault distance test, include a host and a coupler |
Welcome you contact us for more information and service.
Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(single-shot/ multi-shot).
There are three test mode of XHGG502, low voltage pulse, high voltage flashover, ARC multi-shot.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------