China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
  • China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
  • China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
  • China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
  • China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
Find Similar Products
  • Overview
  • Product Description
  • Product Features
  • Function
  • Product Parameters
Overview

Basic Info.

Model NO.
XHGX507X
Usage
Digital Cable Tester
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Yellow
Transport Package
Wooden Case Filled with Foam
Specification
18kg
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
1000pieces /Year

Product Description

 

Product Description

This XHGX507X underground cable pipe locator uses the electromagnetic field signal of the underground cable to locate the cable, and gives the depth and current readings, so as to realize the cable detection function.


Specifications that the device complies with
U.S.
The transmitter and receiver of this device comply with Part 15 of the U.S. FCC Rules:
CFR 47 Part2: 2004
CFR 47 Part15: 2006
ANSI C63.4: 2003
Europe
This equipment complies with the relevant provisions of European Directive 1999/5/EC:
ETSI EN 300 330-2:2006
ETSI EN 301 489-1:2005
ETSI EN 301 489-3: 2002
China
CJJ 61-2003 Technical regulations for detection of urban underground cables

 

Product Features



Transmitter Features:
Displays the current output frequency.
Display the current output power; it can display low-grade, mid-grade, high-grade and full-grade respectively.
Display the current working mode; can display direct connection, coupling, induction respectively.
Displays the current loop current value; the effective display is 0-999 mA.
Display the current loop impedance value; the effective display is 00001 - 20000 ohms.
Indicates the current battery level; it is represented by a battery symbol, all black is full power, and the left side is the current battery percentage display.

Receiver Features:
Displays the current receiving frequency value; the initial power-on is 577Hz.
The signal strength is represented by the length of the grating; the grating moves from both sides to the middle, and the signal is too strong or out of range when the grating is full.
The signal strength is indicated by the number; the valid range is 00.0-99.9, when 99.9 is displayed, the signal is too strong or out of range.
A colored compass indicates the direction of the pipeline.
Displays the depth of the measured underground line and the current on the line.
The gain is automatically adjusted by default, which means the amplification factor of the signal currently processed by the receiver, and the dynamic range is 000-140db; The initial boot is 60db.
The way the receiver receives the signal, respectively, displays narrow peak, wide peak, trough, broad peak arrow, peak + trough, and external equipment; the initial power-on is wide peak. External devices are automatically recognized.
Indicates the current battery level; indicated by the battery symbol.
Display the current working status of the buzzer, which is represented by the horn symbol plus a line. One line is low loudness, two lines are medium loudness, three lines are high loudness, and a cross is to turn off the buzzer. The initial power-on is to turn off the buzzer.
Off the cable an arrow automatically appears to indicate the cable location; two arrows appear above the cable.
When using the SS frequency, this function displays the direction of the signal current to assist the operator in path finding.
When using the SS frequency, the receiver will display the phase of the signal. Long press the frequency key to clear the phase.

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

 


 

Function

1) It can quickly and effectively determine the direction and depth of underground  cable /metal pipelines. It can also identify power outages and live cables, and use the A-frame to accurately locate low-resistance cable faults to ground.
2) It has signal strength indication, left and right arrow indication, and compass direction indication.
3) The maximum depth of the detection pipeline can reach 20 meters.
4) Automatic sounding: When the instrument is placed above the pipeline, it will automatically display the true depth of the target pipeline.
5) Signal identification: Accurate identification of cables from three dimensions of signal amplitude, signal direction and signal phase.
6) Current direction indication: It can track the current direction and phase of the signal, effectively improving the accuracy of the search path.
7) The 70% sounding method of automatic prompting can easily determine the 70% signal point through graphics and prompt sounds.


 

Product Parameters

Transmitter technical parameters
This machine is a multi-frequency high-power transmitter, with constant power output, automatically matching the external load, to ensure that the machine works in the best state. With ohmmeter function, it can detect external voltage and test continuous loop resistance, which can help to determine the nature of the fault.
1) Optional frequency: output 31 kinds of frequency sinusoidal AC signal, namely 98Hz, 128Hz, 256Hz, 480Hz, 491Hz, 512Hz, 577Hz, 640 Hz, 815Hz, 982Hz, 1.02kHz, 1.17KHz, 1.45KHz, 1.52KHz , 4.1KHz, 8.01KHz, 8KHz, 8.44KHz, 9.5KHz, 9.82 KHz, 29.4KHz, 33 KHz, 38 KHz, 65.5 KHz, 78.1KHz, 80.43 KHz, 82KHz, 83.1KHz, 89KHz, 133KHz, 200KHz.
2) Fault detection and identification signal positioning mode, sound transmission mode, current direction signal SS Low, SS High.
3) With intelligent signal identification phase function.
4) Ohmmeter function, can detect external resistance, external dangerous voltage prompt.
5) Three signal transmission methods: direct connection method, coupling method and induction method.
6) Display content: frequency setting, battery status, digital display output current and loop resistance, output mode, external power supply, external voltage warning.
7) The output power is adjustable, with four gears: low-grade, mid-grade, high-grade and full-grade.
8) The maximum output current is not less than 1A; the maximum output power is not less than 12W.


Receiver technical parameters
The receiver uses a 3.5-inch true color LCD display, displaying signal strength figures, amplitude light bars, compass pointing, left
Right arrow pointing, current direction indication, used to indicate the strength of the signal, optical cable location, fault detection, optical
Cable identification, depth measurement.
1) 5 display modes: wide peak value, valley value, narrow peak value, wide peak value arrow, and peak value plus valley value.
2) With broadband receiving technology, it can provide personalized customization (within 100Hz-200kHz) according to customer needs.
3) Available frequencies: 10 kinds, 50Hz, 60Hz, LF, 577Hz, 8KHz, 33 KHz,82KHz, 133KHz, current direction signal SS Low, SS High.
4) Digital direct reading depth range: 0-20 meters. Accuracy: ±5% within 3 meters, ±10% within 8 meters.
5) Display content: signal strength, signal amplitude light bar, left and right arrow indication, compass direction indication, current direction indication, current phase display, real-time depth indication, intelligent signal recognition phase, signal gain.
6) It has the function of compass guidance.
7) It has the function of intelligent signal identification phase.
8) Signal identification: Accurate identification of optical cables and cables from the three dimensions of signal amplitude, signal direction and signal phase.
9) Current direction indication: It can track the current direction and phase of the signal, effectively improving the accuracy of the search path.
10) 3.5-inch 24-bit color LCD display. The backlight brightness is adjustable to adapt to various environments.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Brief introduction to the transmitter

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

Transmitter instrument panel and function introduction
The transmitter is a signal source that can emit enough power, and is one of the cores of this set of instruments. It has complete functions, high intelligence and simple operation.

Panel Introduction
Note: see the picture above
1. Key  2. Output port  3. LCD display area  4. Frequency compound key  5. Power adjustment
compound key
6. Menu composite key  7. Charging port

Function introduction
1. Switch key: This switch is a self-locking switch; press it to turn on the power, the transmitter is in working state; pop up to disconnect the power supply, the transmitter is in a shutdown state.

2. Output port: This port is a multi-core dedicated aviation socket; it is used to change the output mode of the signal. Connecting the direct connection line is the direct connection mode; inserting the coupling clamp connection is the coupling mode; not connecting the line is the induction mode.

3. Liquid crystal display area: Display the required basic information.

4. Frequency key: This key is a jog soft switch; the frequency of the output signal can be changed every time it is pressed; the initial power-on is 577Hz. Initially 8KHz in sensing mode. In the frequency setting menu interface, press this key to select or cancel the frequency covered by the light bar; in the multi-frequency mode setting, press this key to choose to replace the output frequency channel.

5. Power key: This key is a jog soft switch; the output power can be changed once every time it is pressed, and it can be selected from low-grade, mid-grade, high-grade and full-grade. Flip through the frequency menu; in multi-frequency mode setting, press this key to select the output frequency.

6. Menu key: This key is a jog soft switch; press this key to cycle into the frequency setting menu, resistance measurement mode, and multi-frequency mode setting.

7. Charging port: This port is a Φ2.1 charging stand; it is used to connect a special charger to charge the battery.



-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Transmitter interface display content

Frequency  Display the current output frequency
Power Display the current output power; it can display low-grade, mid-grade,
high-grade and full-grade respectively
Mode Displays the current working mode; direct connection, coupling, and induction can
be displayed separately.
Current Display the current loop current value; the effective display is 0-999 mA.
Impedance: Display the current loop impedance value; the effective display is
00001-20000 ohms.
Power Indicates the current battery power; it is represented by a battery symbol, all black is
full power, and the left is the current power percentage display.
Matching tip When the circle below the picture starts to roll, it means that the transmitter is
working stably.
Frequency setting 577Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 133kHz, ss low, ss high, multi-frequency mode.


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Signal output mode - transmitter working mode
The transmitter can output different AC signals, which can be applied to the target cable in three ways (direct connection, coupling, induction). To ensure reliable signal transmission on the target cable, there must be a reliable loop in the line. It can be an indirect loop composed of the ground, a capacitive loop composed of a distributed capacitance formed between a long enough cable and the ground, or a direct loop composed of short-circuit fault points between lines. Different circuits meet different tests.


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Brief introduction to the receiver

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator










Receiver panel and function introduction
A receiver is an integration of a system circuit capable of receiving a specific magnetic field and converting it into an electrical signal to display it and prompt the operator. It is the second core of this set of instruments. It is fully functional, highly intelligent, portable, lightweight, and easy to operate. 

China Factory Underground Pipeline Detector Multi Function Cable Fault Locator



 
China Factory Underground Pipeline Detector Multi Function Cable Fault Locator

Interface display content function introduction
Receiver Broad Peak Arrow Mode Interface
Frequency: Display the current receiving frequency value; the initial value is 577Hz when power on.

Grating: The signal strength is indicated by the length of the grating; the grating moves from both sides to the middle, and the signal is too strong or out of range when the grating is full.

Three digits: the signal strength is indicated by the size of the number; the valid range is 00.0-99.9, when 99.9 is displayed, the signal is too strong or out of range.

Color compass: indicates the direction of the pipeline.

Depth & Current: Indicates the measured depth of the underground pipeline and the current on the pipeline.

Gain: Indicates the magnification of the signal currently processed by the receiver, with a dynamic range of 000-140db; it is automatically adjusted by default. The initial boot is 60db.

Mode: Indicates the way the receiver receives the signal, and displays narrow peak , wide peak , trough , broad peak arrow , peak + trough and external equipment ; the initial power-on is wide peak. External devices are automatically recognized.

Battery level: Indicates the current battery level; it is indicated by the battery symbol.

Volume: Indicates the current working status of the buzzer, represented by the horn symbol plus a line, one line is low loudness, two lines are medium loudness, three lines are high loudness, and a cross is to turn off the buzzer. The initial power-on is to turn off the buzzer.

Left and Right Arrows: Arrows automatically appear off the cable to indicate the cable location ; two arrows appear above the cable.

Current direction: When using the SS frequency, this function can display the direction of the signal current to assist the operator in path finding.

Phase Indication: When using the SS frequency, the receiver will display the phase of the signal. Long press the frequency key to clear the phase.
 

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
China Factory Underground Pipeline Detector Multi Function Cable Fault Locator
Receiver characteristics

1) Cable positioning: Select the wave crest method and use parallel antenna positioning to quickly track the target cable. When it is above the cable, the signal is the largest and the two sides are reduced. Choose the valley method and use the vertical antenna for positioning. When there are no adjacent cables and interference sources, the positioning is more accurate and reliable. When the receiver is above the cable, the signal is the smallest and the signal on both sides is large.

2) Depth measurement: In direct connection mode, the depth is measured directly. Place the receiver directly above the pipeline, and keep the instrument body still when the direction indicated by the compass points straight ahead, and the real-time sounding value is displayed in the upper left corner.

voice prompt
A great feature of this instrument is that it has a voice prompt, which can reduce the operator's eye fatigue when working for a long time, and make the detection work more simple and clear. The volume of the sound emitted by the receiver is proportional to the strength of the received signal. Under unity gain, when the sound from the receiver is loud and rapid, it means that the received signal is strong, and vice versa, it means that the
received signal is weak. When the receiver is in the crest method, the sound is loudest and sharp right above the cable, and the sound is small and sparse on both sides. When the receiver is in the valley method, the sound is the smallest and most sparse right above the pipeline, and the sound is loud and tight on both sides.


-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Receiver working mode
working principle
When a signal is applied to the cable, there is a current on the cable, and the current generates a magnetic field that radiates around the cable. The frequency of the magnetic field is consistent with the frequency of the applied signal. The strength is the cable as the center of the circle and the radiation is decreased, and the direction is the tangent direction of a certain point on the radiation circle.
The receiver receives the magnetic field signal or the leaked electric field signal radiated by the cable through the internal antenna or external input device, and can be processed in two different working modes, and the signal strength change is prompted to the operator.

Signal reception mode - receiver working mode

Crest method (narrow peaks , broad peaks , broad arrows , peaks + valleys )
Trough method (trough )

 
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Welcome you contact us for more information and service!~





 

China Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault LocatorChina Factory Underground Pipeline Detector Multi Function Cable Fault Locator
 



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier