Customization: | Available |
---|---|
After-sales Service: | Warranty Certificate |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This XHGX507X underground cable pipe locator uses the electromagnetic field signal of the underground cable to locate the cable, and gives the depth and current readings, so as to realize the cable detection function.
Specifications that the device complies with
U.S.
The transmitter and receiver of this device comply with Part 15 of the U.S. FCC Rules:
CFR 47 Part2: 2004
CFR 47 Part15: 2006
ANSI C63.4: 2003
Europe
This equipment complies with the relevant provisions of European Directive 1999/5/EC:
ETSI EN 300 330-2:2006
ETSI EN 301 489-1:2005
ETSI EN 301 489-3: 2002
China
CJJ 61-2003 Technical regulations for detection of urban underground cables
1) It can quickly and effectively determine the direction and depth of underground cable /metal pipelines. It can also identify power outages and live cables, and use the A-frame to accurately locate low-resistance cable faults to ground.
2) It has signal strength indication, left and right arrow indication, and compass direction indication.
3) The maximum depth of the detection pipeline can reach 20 meters.
4) Automatic sounding: When the instrument is placed above the pipeline, it will automatically display the true depth of the target pipeline.
5) Signal identification: Accurate identification of cables from three dimensions of signal amplitude, signal direction and signal phase.
6) Current direction indication: It can track the current direction and phase of the signal, effectively improving the accuracy of the search path.
7) The 70% sounding method of automatic prompting can easily determine the 70% signal point through graphics and prompt sounds.
Transmitter technical parameters
This machine is a multi-frequency high-power transmitter, with constant power output, automatically matching the external load, to ensure that the machine works in the best state. With ohmmeter function, it can detect external voltage and test continuous loop resistance, which can help to determine the nature of the fault.
1) Optional frequency: output 31 kinds of frequency sinusoidal AC signal, namely 98Hz, 128Hz, 256Hz, 480Hz, 491Hz, 512Hz, 577Hz, 640 Hz, 815Hz, 982Hz, 1.02kHz, 1.17KHz, 1.45KHz, 1.52KHz , 4.1KHz, 8.01KHz, 8KHz, 8.44KHz, 9.5KHz, 9.82 KHz, 29.4KHz, 33 KHz, 38 KHz, 65.5 KHz, 78.1KHz, 80.43 KHz, 82KHz, 83.1KHz, 89KHz, 133KHz, 200KHz.
2) Fault detection and identification signal positioning mode, sound transmission mode, current direction signal SS Low, SS High.
3) With intelligent signal identification phase function.
4) Ohmmeter function, can detect external resistance, external dangerous voltage prompt.
5) Three signal transmission methods: direct connection method, coupling method and induction method.
6) Display content: frequency setting, battery status, digital display output current and loop resistance, output mode, external power supply, external voltage warning.
7) The output power is adjustable, with four gears: low-grade, mid-grade, high-grade and full-grade.
8) The maximum output current is not less than 1A; the maximum output power is not less than 12W.
Receiver technical parameters
The receiver uses a 3.5-inch true color LCD display, displaying signal strength figures, amplitude light bars, compass pointing, left
Right arrow pointing, current direction indication, used to indicate the strength of the signal, optical cable location, fault detection, optical
Cable identification, depth measurement.
1) 5 display modes: wide peak value, valley value, narrow peak value, wide peak value arrow, and peak value plus valley value.
2) With broadband receiving technology, it can provide personalized customization (within 100Hz-200kHz) according to customer needs.
3) Available frequencies: 10 kinds, 50Hz, 60Hz, LF, 577Hz, 8KHz, 33 KHz,82KHz, 133KHz, current direction signal SS Low, SS High.
4) Digital direct reading depth range: 0-20 meters. Accuracy: ±5% within 3 meters, ±10% within 8 meters.
5) Display content: signal strength, signal amplitude light bar, left and right arrow indication, compass direction indication, current direction indication, current phase display, real-time depth indication, intelligent signal recognition phase, signal gain.
6) It has the function of compass guidance.
7) It has the function of intelligent signal identification phase.
8) Signal identification: Accurate identification of optical cables and cables from the three dimensions of signal amplitude, signal direction and signal phase.
9) Current direction indication: It can track the current direction and phase of the signal, effectively improving the accuracy of the search path.
10) 3.5-inch 24-bit color LCD display. The backlight brightness is adjustable to adapt to various environments.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Brief introduction to the transmitter
Transmitter instrument panel and function introduction
The transmitter is a signal source that can emit enough power, and is one of the cores of this set of instruments. It has complete functions, high intelligence and simple operation.
Panel Introduction
Note: see the picture above
1. Key 2. Output port 3. LCD display area 4. Frequency compound key 5. Power adjustment
compound key
6. Menu composite key 7. Charging port
Function introduction
1. Switch key: This switch is a self-locking switch; press it to turn on the power, the transmitter is in working state; pop up to disconnect the power supply, the transmitter is in a shutdown state.
2. Output port: This port is a multi-core dedicated aviation socket; it is used to change the output mode of the signal. Connecting the direct connection line is the direct connection mode; inserting the coupling clamp connection is the coupling mode; not connecting the line is the induction mode.
3. Liquid crystal display area: Display the required basic information.
4. Frequency key: This key is a jog soft switch; the frequency of the output signal can be changed every time it is pressed; the initial power-on is 577Hz. Initially 8KHz in sensing mode. In the frequency setting menu interface, press this key to select or cancel the frequency covered by the light bar; in the multi-frequency mode setting, press this key to choose to replace the output frequency channel.
5. Power key: This key is a jog soft switch; the output power can be changed once every time it is pressed, and it can be selected from low-grade, mid-grade, high-grade and full-grade. Flip through the frequency menu; in multi-frequency mode setting, press this key to select the output frequency.
6. Menu key: This key is a jog soft switch; press this key to cycle into the frequency setting menu, resistance measurement mode, and multi-frequency mode setting.
7. Charging port: This port is a Φ2.1 charging stand; it is used to connect a special charger to charge the battery.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Transmitter interface display content
Frequency | Display the current output frequency |
Power | Display the current output power; it can display low-grade, mid-grade, high-grade and full-grade respectively |
Mode | Displays the current working mode; direct connection, coupling, and induction can be displayed separately. |
Current | Display the current loop current value; the effective display is 0-999 mA. Impedance: Display the current loop impedance value; the effective display is 00001-20000 ohms. |
Power | Indicates the current battery power; it is represented by a battery symbol, all black is full power, and the left is the current power percentage display. |
Matching tip | When the circle below the picture starts to roll, it means that the transmitter is working stably. |
Frequency setting | 577Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 133kHz, ss low, ss high, multi-frequency mode. |