Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
  • Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Find Similar Products
  • Overview
  • Product Description
  • Product Features
Overview

Basic Info.

Model NO.
XHGG501B+XHLJ504+XHHV535-4Z
Usage
Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester, Power Electric Cable
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Orange
Impact Voltage
0-32kv
Surge Energy
0-2048j
Transport Package
Wooden
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
300 Pieces /Year

Product Description

 

 

Product Description

XZH TEST Portable cable fault location system

XHGG501B+XHLJ504+XHHV535-4Z is designed for:
Low and medium voltage underground cable fault location.
 
★XHHV535-4Z High voltage 2048 J surge generator is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 32 kV. It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults.
 
★Cable fault pre-locator: XHGG501B The cable fault tester is suitable for measuring low resistance, short circuit, open circuit disconnection faults, as well as high resistance leakage and high resistance flashover faults in power cables, high frequency coaxial cables, telephone cables, street lighting cables and buried wires of various materials with different cross sections and different media. Superb cable management system with automatic test report generation.
 
★cable route tracer: XHLJ504 A special multifunction instrument for accurately detecting the location of buried cable paths and burial depths within a certain range; Path detection is accomplished by the path signal generator and path signal receiver working in conjunction with the test; through their operation in conjunction with each other, the cable path is precisely located within the approximate cable burial range. Its receiver can be used as cable fault pinpointer.


Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator


The system include a ARC multi-shot cable fault pre locator, a high voltage surge generator and a cable fault pinpointer and cable pipe locator.
Model number: XHGG501B, XHHV535-4TS, XHLJ504

XHGG501B Cable fault pre-locator
XHLJ504 Cable route tracer & Cable fault pinpointer
XHHV535-4Z 0-32kV high voltage surge generator



The system can quickly detect low-resistance, short-circuit, open-circuit and disconnection faults of various types of power cables with different cross-sections and different media, high-frequency coaxial cables, local telephone cables, street lamp cables, and buried wires, as well as high-resistance leakage and high-resistance flashover for permanent main insulation faults , calibrate the cable length.

Product Features

1) Cable fault pre locator XHGG501B: With isingle chip computer control, 5.7" color display touch operation mode, strong anti-interference ability;
2)System functions: fault distance measurement, fault pinpoint location, propagation speed test.
3)System test methods: low-voltage pulse,Impulse Current Method (ICE-Method = Impulse
Current Equipment), audio method, , acoustic-magnetic synchronization method, electromagnetic induction method, etc.;

4)TDR Test distance: ≤30km
5)Measurement accuracy: Rough measurement error: ±10m (absolute value) or 1% (relative value), fine measurement error: ±0.2m (fixed point, path, depth); 
6)TDR Sampling frequency: 100MHz, minimum resolution 0.5m (100m/us)
7)TDR Sampling method: automatic continuous sampling, never miss any discharge waveform.
8)Low voltage pulse: Width: Adaptive Amplitude: 100Vpp
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
 

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Below is cable fault distance measured by using high voltage flashover method(ICE test mode, work together with a high voltage pulse generator. 
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator



Engllish version avaible

Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
 



Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Product Features
1. Using the traditional electromagnetic induction principle, strong anti-interference ability.
2. With over-current and short-circuit protection functions, it is safe and reliable.
3. High power output, not limited by cable length, open circuit can also find a path.
4. The output is steplessly adjustable, suitable for various test sites, with strong adaptability.
5. Super strong magnification, the detection depth is greater than 10 meters.
6. Ultra-low power consumption design, the quiescent current is less than 10mA.
7. The design of the analog meter, the signal strength and trend are clear at a glance.
8. The zero level can be adjusted arbitrarily, which is suitable for all kinds of strong and weak scenes.


This cable pipe locator is mainly composed of transmitter and receiver, the two parts are shown as below.

Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
The receiver with headphone work together can be used as cable fault pinpointer.
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator



--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Description
The high-voltage pulse generator fully complies with DL/T846-2016 "General Technical Conditions for High Voltage Test Equipment" and DL/T474-2017 "Guidelines for the Implementation of Field Insulation Tests". It is mainly used for impact discharge during fault testing of cables with voltage levels of 35kV and below; it can also be used for DC withstand voltage tests of other electrical equipment.

This device integrates DC high-voltage source, energy storage capacitor, and discharge ball gap into one. This equipment completely replaces the traditional test transformer weighing hundreds of kilograms, operation box and pulse energy storage capacitor (generally a set of 5kVA transformer weighs more than 60 kg, and the control box more than 30 kilograms, and more than 20 kilograms of pulse energy storage capacitors).

The power supply adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, which makes the whole machine simple in structure and ultra-light in weight. The pulse generator adopts humanized design and operation mode, which is safe and reliable. It really achieves the effect of not being damaged by impact, and it can also work normally when the high voltage is short-circuited to the ground. It is currently the lightest and most user-friendly portable DC impact high-voltage equipment. It is an ideal product for power cable fault detection.





Technical parameters

Impact high voltage 0-32kV 
High voltage partial pressure 2.5 level
Built-in capacitor 4μF
Discharge power (2048J@32kV)
Impact power 400W
Over temperature protection 85ºC
Volume(mm) 420L×325W×480H
Weight not more than 40kg
Power supply AC220V±15%, 50Hz±2Hz(60Hz can be customized)
Ambient temperature -20~+50ºC


Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Panel function description:
  1. High voltage output (DC): When DC withstand voltage, connect the high voltage output line.
  2. High voltage output (EMP): When impact discharge, connect the high voltage output line.
  3. Safety ground: the ground of the instrument casing, to prevent the instrument casing from being electrified or personnel from getting an electric shock.
  4. Time setting: set the discharge time interval.
  5. Voltmeter: High voltage output voltage indication, used to display voltage value in real time.
  6. Power outlet: instrument working power, AC 220V±10%/50Hz±1Hz.
  7. Fuse socket: where the fuse of the AC 220V power supply system is installed.
  8. Power switch: "Stage I" means to turn on the AC 220V power supply to supply power to the system;
"Gear 0" means turn off the AC 220V power supply to power the system.
    9. Over-current protection switch: When pressed, it means that the over-current protection function has started; when it is popped up, it means that the instrument has triggered the over-current protection.
     10. Start button/zero indicator light:
When the zero indicator light is on (yellow), it means that it is in the zero state, press the start button to start the high voltage output;
When the zero position indicator light is off, it means that it is not in the zero position state. After turning the voltage adjustment knob counterclockwise to the zero position, the zero position indicator light is on, and then press the start button to start the high voltage output.
  11. Stop button/high-voltage indicator light: When the test is completed or abnormality occurs, press this button to cut off the high-voltage output, the high-voltage indicator light is on, indicating that the high-voltage output has been started; the high-voltage indicator light is off, indicating that the high-voltage output has stopped.
   12. Voltage adjustment knob: used to adjust the voltage; adjust the output high voltage clockwise to increase from small to large, and adjust the output high voltage counterclockwise to decrease from large to small.
   13. Discharge button: When the high voltage is stopped, press this button to manually discharge the internal storage power.
   14. Ammeter: Indicates the magnitude of the low-voltage measurement current.
  15. Sampling place: The negative terminal of the pulse energy storage capacitor has a high voltage and must be reliably grounded. It is used for sampling when the waveform is sampled in the high-voltage flashover state of the cable fault tester. (Sampling without high-voltage flashover still requires reliable grounding).

     16. High-voltage ground: also known as high-voltage tail, the internal devices of the instrument are grounded.


In the latest version of the device, we have added the DC withstand voltage connection channel and added the overcurrent protection button. The equipment is safer to use, the equipment self-protection system is more perfect, and the DC voltage resistance function is more clear.



--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

XZHTEST
We are manufactuer of cable fault location system.
Welcome you contact us for more information. It is our pleasure to provide you with professional technical solution schemes.

Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
 

Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator
Factory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault LocatorFactory Xzh Test Tdr 0-32kv Low Medium Voltage Underground Cable Fault Locator

 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier