Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: Warranty Certificate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
  • Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
  • Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
  • Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
Find Similar Products

Basic Info.

Model NO.
XHJJ302A
Transport Package
Wooden
Specification
420mm* 250mm*340mm
Trademark
XZH TEST
Origin
China Xi′an
HS Code
9031809090
Production Capacity
100 Pieces /Year

Product Description

 

XHJJ302A High Voltage Switch Mechanical Properties Tester is special instrument for power system GIS mechanical properties measuring.

XHJJ302A high-voltage circuit breaker analyzer (high-voltage switch mechanical characteristic tester) can accurately measure the mechanical dynamic characteristic parameters of high-voltage circuit breakers of various voltage levels such as low oil, high oil, vacuum, sulfur hexafluoride, etc., and the measurement data is stable , Strong anti-interference, can do experiments in 500KV and below power stations, convenient wiring, simple operation, it is the most convenient tool for high-voltage switch maintenance test.
The switch mechanical properties tester takes advanced technology for the core to process the test data. With high intelligence, lots of functions, accurate test data, strong anti-jamming, easy operation, small size, light weight and so on.


Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
Time measurement:
12 channels
Inherent opening (closing) time
Different periods in the opening (closing) phase
Different periods of opening (closing) between phases
Closing (opening) bounce time (bounce times)
Test range: 0.01ms~15000ms
Accuracy: 0.5%±2 words,
Speed measurement: just opening (just closing) speed
Average speed in a specified time period (stroke period or angle period)
Speed measurement range
 1mm sensor 0.01~25.00m/s,
0.1mm sensor 0.001~2.50m/s,
360° angle sensor 0.01~25.00m/s
Stroke measurement:
 moving contact stroke (stroke)
Contact stroke (open distance)
Overtravel
Sensor measuring range:
 linear displacement sensor 50mm, resolution: 0.1mm, stroke 0.1~50mm
Linear displacement sensor 300mm, resolution: 0.1mm, stroke 10~300mm (optional)
Linear displacement sensor 500mm, resolution: 1mm, stroke 10~500mm (optional)
360 line sensor: 360о, resolution: 0.25о, stroke 1mm~1000mm
Current measurement range
0~15A, resolution: 0.01A, the display current value is the maximum coil current.
Display
320×240 LCD screen with adjustable contrast
Data storage
100 sets of measurement data can be stored
 Printer
 High-speed thermal printer
 
 
Main features
1. The instrument automatically recognizes the opening and closing status of the fracture to prevent misoperation.
2. Independent 12 fracture ports can detect and prompt the connection status of the fracture ports, which is convenient for users to check the wiring.
3. 100 sets of test results can be stored in the machine.
4. Large-screen LCD (320×240) LCD display, advanced gray screen, no reflection or black screen in the sun, graphic and English menu operation prompts, humanized menu interface, easy to operate.
5. The instrument has a powerful graphic analysis function, which realizes the same screen display of waveform and measurement processing data, making the test process more intuitive.
6. There is a delay protection function inside the machine, and the coil voltage can be automatically cut off after the circuit breaker is activated, which well protects the circuit breaker and testing equipment. Independent and special opening and closing control unit, namely opening or closing control unit, can be used for closing or opening test. If one of the control loops is broken, it will not affect the use.
7. This instrument can carry out electric and manual opening and closing tests.
8. It can conduct high and low voltage experiments and automatically find the lowest opening or closing voltage.
9. The reclosing test can be used to measure parameters such as closing, opening and closing.
10. Parameter measurement of vacuum contactor (single coil).
11. Complete the circuit breaker aging test (life test) automatically.
 

 

Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test
Digital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics TestDigital Automatic High Voltage Circuit Breaker Analyzer Switch Mechanical Characteristics Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now