| Test Function | Output Voltage | Measure Range | Accuracy | Resolution | ||
| Insulation Resistance | 250V(±10%) | 0~10MΩ | ±3%rdg±5dgt | 0.01MΩ | ||
| 10~100MΩ | 0.1MΩ | |||||
| 100~1000MΩ | 1MΩ | |||||
| 1G~10GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
| 500V(±10%) | 0~10MΩ | ±3%rdg±5dgt | 0.01MΩ | |||
| 10~100MΩ | 0.1MΩ | |||||
| 100~1000MΩ | 1MΩ | |||||
| 1G~10GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
| 1000V(±10%) | 0~20MΩ | ±3%rdg±5dgt | 0.01MΩ | |||
| 20~200MΩ | 0.1MΩ | |||||
| 200~1000MΩ | 1MΩ | |||||
| 2G~20GΩ | ±5%rdg±5dgt | 0.01 GΩ | ||||
| 2500V(±10%) | 0~2000MΩ | ±3%rdg±5dgt | 1MΩ | |||
| 2000MΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||||
| 20GΩ~200GΩ | ±20%rdg±10dgt | 0.1GΩ | ||||
| 5000V(±10%) | 0~2000MΩ | ±3%rdg±5dgt | 1MΩ | |||
| 2000MΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||||
| 20GΩ~200GΩ | ±20%rdg±10dgt | 0.1GΩ | ||||
| Test Function | Measure Range | Accuracy | Resolution | |||
| DC Voltage | DC 0.0V~1000V | ±1.5%rdg±3dgt | 0.1V | |||
| AC Voltage | AC 0.0V~750V | ±1.5%rdg±3dgt | 0.1V | |||
| Function | Insulation resistance test, AC voltage test, DC voltage measurement |
| Ambient Temperature and Humidity | 23ºC±5ºC,below 75%rh |
| Power | DC 9V 6-section LR14 Dry Battery Standby for more than 100 hours |
| Rated Voltage | 250;500;1000;2500;5000V |
| Rated Voltage Accuracy | ±10% |
| Output short-circuit Current | ≥2mA |
| Absorption Ratio Measurement | Have |
| Polarization Index Measurement | Have |
| Test Method | DC voltage drop method |
| Test Voltage | DC voltage measurement |
| Maximum Capacitive Load | Operates below 1uF |
| Shift Gear | Automatic shifting |
| Back light | Controllable gray backlight, suitable for use in dim places |
| Display Mode | LCD display, gray backlight |
| Measurement Indication | LED flashes during measurement |
| LCD Size | 108mm×65mm |
| Instrument Size | L/W/H:240mm×188mm×85mm |
| Test Line | High pressure rod: red 1 meter Test line: black 1 meter green 1 meter |
| Measurement Time | Voltage 2 times/sec, insulation resistance 7 seconds/time |
| Line Voltage | measure below AC600V |
| Data Storage | 500 groups,"MEM"storage instructions, display"FULL"symbol indicates that the storage is full |
| Data Review | The "MR" symbol indicates when looking up data |
| Overflow Display | "OL" symbol indicates over-range overflow |
| Alarm Function | Alarm when the measured value exceeds the alarm setting value |
| Battery Voltage | Low battery voltage symbol, prompt battery replacement when battery voltage is low |
| Automatic Shutdown | "APO"Indicate Automatic Shutdown After 15 Minutes |
| Power Consumption | Standby: About 40mA (backlight off) |
| Turn on backlight: about 43mA | |
| Measurement: about 75mA (backlight off) | |
| Weight | Instrument:1230g (Including battery) |
| Working Temperature and Humidity | -10ºC~40ºC;Below 80%rh |
| Storage Temperature and Humidity | -20ºC~60ºC;Below 70%rh |
| Insulation resistance | 200MΩ or more (500V between circuit and case) |
| Pressure Resistance | AC 5160V/rams(Between circuit and case) |
| Electromagnetic properties | IEC61326(EMC) |
| Suitable for Safety Regulations | IEC61010-1(CAT III 300V,CAT IV 150V,Pollution degree 2); |