Customization: | Available |
---|---|
After-sales Service: | Support |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Function | Simultaneously measure two-way AC voltage, current, phase between voltages, phase between currents, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, and determine the transformer wiring group, inductance, capacitance test the secondary circuit and the bus differential protection system, read out the phase relationship between each group of CTs in the differential protection, check whether the wiring of the watt-hour meter is correct or not, and repair the line equipment, etc. |
Power supply | DC9V Alkaline dry battery (1.5V AA×6) |
Measuring range (Fully automatic) |
Voltage:AC 0.00V~600V |
Current:AC 0.0mA~20.0A | |
Phase:0.0°~360.0° | |
Frequency:45.00Hz~65.00Hz | |
Active power:0.0W~12kW | |
Reactive power:0.0VAR~12kVAR | |
Inspecting power:0.0VA~12kVA | |
power factor:-1~+1 | |
Jaw size | Small-pointed current clamp: 7.5mm×13mm (model selection) Round mouth current clamp: 35mm×40mm (model selection) |
Resolution | Voltage:AC 0.01V |
current:AC 0.1mA | |
Phase:0.1° | |
Frequency:0.01Hz | |
Active power:0.1W | |
Reactive power:0.1VAR | |
Inspecting power:0.1VA | |
power factor:0.001 | |
data storage | 1500 group |
RS232 interface | USB-RS232 Interface, the stored data is uploaded to the computer, which is convenient for analysis and management of data |
Power consumption | When the backlight is turned on, the maximum power consumption is 70mA, and the battery works continuously for 14 hours |
When the backlight is turned off, the meter consumes 40mA, and the battery works continuously for 20 hours | |
display mode | LCD display,240dots×160dots |
Meter size | length Width Thickness:196mm×92mm×54mm |
Detection rate | About 2 seconds/time |
data retention | During the test, press the HOLD key to keep the data, and the "HD" symbol will display |
Automatic shut-down | After about 15 minutes of power on, the meter automatically shuts down to reduce battery consumption |
Backlight function | Yes, suitable for dark places and night use |
Voltage detection | When the battery voltage is lower than 7.2V, the low battery voltage symbol will be displayed to remind you to replace the battery |
Weight | Host: 550g (with battery) |
Pointed small current clamp: 170g×2 | |
Round mouth current clamp: 185g×2 | |
Test line: 250g | |
Test lead length | 1.5m |
Current clamp wire length | 2m×φ5mm |
Working temperature and humidity | -10ºC~40ºC;below 80%Rh |
Storage temperature and humidity | -10ºC~60ºC;below 70%Rh |
input resistance | Test voltage input impedance: 2MΩ |
Pressure resistance | Withstand 1000V/50Hz sine wave AC voltage between instrument circuit and enclosure for 1 minute |
Insulation | Between instrument line and sheath shell ≥100MΩ |
structure | Double insulation with insulating anti-vibration jacket |
Suitable for safety regulations | IEC61010-1 CAT III 600V,IEC61010-031,IEC61326,Pollution degree 2 |