XZH TEST cable fault location system is designed for low medium high voltage underground cable fault detection.
★Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), ICE(impulse current test method), multiple impulse(ARC-multi-short)arc reflection method.
★cable path tracing, buried depth detection and live and unlive cable identification: XHGX507 multi-functional cable pipe locator is an all-digital locator with clear display and reliable positioning. Graphical operation instructions and sound indication, making it the easiest-to-use pipe locator available today. Powered by rechargeable battery, it can also display cable depth and current.
★Cable fault pinpoint location: XHDD503C uses acoustic-magnetic synchronization method, digital display waveforms of sound and magnetic, judge cable fault point by time difference and earphone, make detection more easier.
The portable cable fault location system is configured with the removable ARC cable fault locator with ultra-high brightness, large LCD screen 12.1" display with touch control, making the process of fault pre-location quick, easy and efficient.
High voltage 2048 J surge generator is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 8, 16 and 32 kV.
It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults.
XHGG502 | ARC cable fault pre-locator | For cable fault rough distance test , test method: low voltage pulse, ICE, ARC(multi-shot), DECAY, ARC(single-shot) |
XHDD503C | Digital cable fault pinpointer | For precise location of cable fault point |
XHGX507 | Comprehensive cable fault tester | detect cable path, buried depth, identify cables, locate low voltage to ground cable fault |
XHHV535-4TS | High voltage pulse generator | discharge during cable fault location/cable thumping |
Welcome you contact us for more information of each equipment.
XHDD503C
The cable fault location instrument uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.
This cable fault pinpointer is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Fault. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites".
1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
2 | Channel gain | 8 levels adjustable. |
3 | Magnetic channel gain | 8 levels adjustable. |
4 | Output gain | 16 levels (0~112db) |
5 | Output impedance | 350Ω |
6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
7 | Path identification accuracy | less than 0.5m. |
8 | Power supply | 4*18650 standard lithium batteries. |
9 | Standby time | more than 8 hours. |
10 | Volume | 428L×350W×230H |
11 | Screen pixels | 854-480 |
12 | Brightness | 800nit |
13 | Transmission speed unit | 0-100ms |
14 | Accuracy | 1ms |
15 | Sound bandwidth | 100-1.6khz |
16 | Magnetic coil bandwidth | 100-20kHZ |
17 | Both sound and magnetism are | greater than 75db |
18 | Weight | 6.5kg. |
19 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHGG502 ARC Cable fault pre locator
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; roughly test cable fault distance
Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(single-shot/ multi-shot).
There are three test mode of XHGG502, low voltage pulse, high voltage flashover(Impulse current method), ARC multi-shot.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502.
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502
--------------------------------------------------------------------------------------------------------------------------------------------------------
The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHGX507 is a multifunction cable fault tester. It can be used to detect live and uncharged cable path, identify cables, locate cable fault point with A-frame.
Transmitter
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz) |
Working mode | direct connection method, coupling method (caliper method), induction method |
Matching load | 5 ohms-3000 ohms |
Impedance display | 5 digits |
Overheating and over current | automatic protection |
Power output | low gear, middle gear, high gear |
Working frequency | low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), Passive frequency 50Hz |
Antenna mode | valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame) |
Current indication | display the effective current value of the cable under test (unit: mA) |
Working temperature | -10ºC+55ºC |
Power indicator | graphic display |
Battery life | continuous work> 8 hours: intermittent work> 16 hours |
Signal strength indication | ladder diagram, digital range 0-999 |
Gain control | manual adjustment, dynamic range of 100dB |
Detection depth | the maximum detection depth is around 10 meters |
Maximum detection distance | The cable with good insulation can be up to 15km in the direct connection method |
Depth measurement | press the depth key to display three digits, the maximum depth can be measured up to 10 meters |
Accuracy | Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m |
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
XHHV535-4TS
The XHHV535-4TS high voltage pulse generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.
High voltage surge generator XHHV535-4TS |
Surge voltage levels and adjustment ranges |
Level 1 : 0-8KV Level 2: 0-16KV Level 3: 0-32KV |
Surge voltage levels switch | Manual | |
Voltage adjustment type | Continuous | |
Indication | High-voltage side voltage metering, indication of output voltage and current in real time | |
Surge energy at each level | Up to 2048J | |
Operating mode | Single trigger, cycle, DC | |
Operating modes switch | Manual | |
Impact time | about 7 seconds for automatic impact, arbitrary control time for manual impact | |
Impact power | 2KVA | |
Continuous output current | 60mA | |
Built-in capacitor | 4μF/32kV, 16μF/16kV, 64μF/8kV three-speed adjustment | |
Safe operation | With zero start protection function, safe and reliable | |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
Working power | AC 220V±10% 50Hz±2Hz (other voltage and frequency can be customized) | |
DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A |
|
Burn current | Fault conditioning (burning) with current up to 60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV. |
|
Connecting cable | High voltage output cable: 5m, Protective earthing cable:5m,power cord 2.5m. Cables can be customized according to customer requirements. | |
Safety | Over-voltage, Over-current, Overheating protection. Automatic discharge after operation. |
|
Protection rating | Not lower than IP54 | |
Working power | AC 220V±15%, 50Hz±2Hz | |
Dimensions(mm) | 534L×444W×805H | |