Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
  • Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
XHYS101
Power
Electricity
Certification
ISO
Customized
Customized
Color
Blue
Transport Package
Wodden Box
Trademark
XZH TEST
Origin
China
Production Capacity
1000PCS/Year

Product Description

 

Product Description


XHYS101 insulating oil dielectric loss tester is designed and manufactured according to GB/T5654-2007 "Measurement of relative permittivity, dielectric loss factor and DC resistivity of liquid insulating materials". It is used to measure the dielectric loss factor and DC resistivity of liquid insulating media such as insulating oil. Integrated structure. The main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, and DC high voltage source are integrated inside. The instrument adopts all-digital technology, all intelligent automatic measurement, and is equipped with a large-screen (240×128) liquid crystal display. The test results can be automatically stored and printed out, and operators can use it proficiently without professional training.


 

Features

 

(1) The oil cup adopts a three-electrode structure in accordance with the national standard GB/T5654-2007, and the distance between the electrodes is 2mm, which can eliminate the influence of stray capacitance and leakage on the dielectric loss test results.
   (2) The instrument adopts intermediate frequency induction heating and PID temperature control algorithm. This heating method has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed, and convenient control, so that the temperature is strictly controlled within the preset temperature error range.
   (3) The internal standard capacitor is SF6 gas-filled three-electrode capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature and humidity, so that the accuracy of the instrument can still be guaranteed after long-term use.
   (4) The AC test power supply adopts the AC-DC-AC conversion method, which effectively avoids the influence of the mains voltage and frequency fluctuations on the accuracy of the dielectric loss test. Even if the generator generates electricity, the instrument can run correctly.
   (5) Perfect protection function. When there is overvoltage, overcurrent, or high voltage short circuit, the instrument can quickly cut off the high voltage and issue a warning message. When the temperature sensor fails or is not connected, a warning message is issued.
There is a temperature limit relay in the intermediate frequency induction heating furnace. When the temperature exceeds 120 degrees, the relay is released and the heating stops.
   (6) It is convenient to set test parameters. Temperature setting range 0~125ºC, AC voltage setting range
500~2200V, DC voltage setting range is 0~500V.
(7) Adopt large-screen LCD display with backlight and clear display. Friendly man-machine interface, just follow the Chinese menu prompts and input commands, the instrument can automatically test. And automatically store and print test results.
(8) With a real-time clock, the test date and time can be saved, displayed and printed with the test results.
(9) Empty electrode cup calibration function. Measure the capacitance and dielectric loss factor of the empty electrode cup to judge the cleaning and assembly conditions of the empty electrode cup. Calibration data is automatically saved to facilitate accurate calculations of relative permittivity and DC resistivity.


 

Detailed Photos




Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit

Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit
Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit

Product Parameters

  • Power supply voltage: AC 220V±10%
    Power frequency: 50Hz/60Hz ±1%
    Measuring range: capacitance 5pF ~ 200pF
                   Relative permittivity 1.000~30.000
                   Dielectric loss factor 0.00001~100
    DC resistivity 2.5 MΩm~20 TΩm
    Measurement accuracy: capacitance ± (1% reading + 0.5pF)
                   Relative permittivity ± (1% of reading)
                   Dielectric loss factor ±(1% reading+0.0001)
                   DC Resistivity ±(10% of reading)
    Resolution: Capacitance 0.01pF
                   Relative permittivity 0.001
                   Dielectric loss factor 0.00001
    Temperature measurement range: 0~125ºC
    Temperature measurement error: ±0.5ºC
    AC test voltage: 500~2200V continuously adjustable, frequency 50Hz
    DC test voltage: 0~500V continuously adjustable
    Power consumption: 100W
    Appearance size: 500×360×420
    Total weight: 22Kg


 

WELCOME YOU CONTACT US FOR MORE INFORMATION

 

 

 


Company Profile:


 Xi'an Xu&Hui Electromechanical Technology Co.,Ltd is one of famous brand of electrical equipment
tester manufacturer in China, mainly produced TDR underground cable fault locator, capacitors,
insulation resistance tester, transformer oil tester, high voltage generator and earth resistance tester etc.
We have several patents in this industry, and our products are exported well in the global market,
such as America, Brazil, Turkey, Russian,Israel, Thailand, India, etc. 




Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit

Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit

Transformer Insulating Oil Dielectric Loss Tester Tan Delta Test Kit






FAQ:

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: What is your terms of payment ?

A: Payment<=1000USD, 100% in advance. 


If you have other questions, pls send us an inquiry below:

XI'AN XU&HUI ELECTROMECHANICAL TECHNOLOGY CO.,LTD

Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier