Direct Connection Coupling Induction Method Cable Fault Locator

Product Details
Customization: Available
After-sales Service: Warranty
Warranty: 12 Mouth
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Direct Connection Coupling Induction Method Cable Fault Locator
  • Direct Connection Coupling Induction Method Cable Fault Locator
  • Direct Connection Coupling Induction Method Cable Fault Locator
  • Direct Connection Coupling Induction Method Cable Fault Locator
  • Direct Connection Coupling Induction Method Cable Fault Locator
  • Direct Connection Coupling Induction Method Cable Fault Locator
Find Similar Products
  • Overview
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
XHGX507
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Blue
Working Temperature
-10°c——+55°c
Battery Model
Rechargeable Battery
Battery Indication
Graphic Display
Battery Life
Continuous Working >8 Hours
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi&an
Production Capacity
1000

Product Description

The pipeline locator uses the principle of electromagnetic induction to detect the precise direction and depth of underground cables and locate cable open circuits, short circuits and outer sheath fault points. The pipeline locator's intelligence, graphic operation instructions and sound frequency modulation instructions make it the most popular one today. Easy-to-use pipeline locator.

Product Parameters

1. Receiver
Direct Connection Coupling Induction Method Cable Fault Locator
Working frequency: low frequency, medium frequency, high frequency, radio frequency 50HZ
Antenna mode: valley method (vertical coil), crest method (horizontal coil)
Audible indication: FM tones that vary with signal strength
Current indication: displays the effective current value of the cable under test (unit: mA)
Working temperature: -10°C--+55°C
Battery model: rechargeable battery
Battery indication: graphic display
Battery life: continuous working >8 hours: intermittent working >16 hours
Size: 70×20×11CM
Weight: 3kg (with battery)
Signal strength representation: ladder diagram, digital range 0-999
Gain control: manual adjustment, dynamic range is 100db
Detection depth: Maximum detection is not less than 10 meters
Maximum detection distance: up to 15KM with well-insulated cable in direct connection method
Depth measurement: Press the depth key, three-digit display, the maximum depth can be measured up to 2.5 meters
Accuracy*: Low frequency: ±(1-5)%≤2.5 meters Radio frequency: ±(5-12)%≤2.5 meters
*Depends on site environment, shape of non-concentric wires, number of adjacent pipelines, and soil return current


2. Transmitter
Direct Connection Coupling Induction Method Cable Fault Locator
Working frequency: low frequency, medium frequency, high frequency, radio frequency
Working mode: direct connection method, coupling method, induction method
Matching load: 5 ohms - 3000 ohms
Impedance display: five digits
Overheating and overcurrent: automatic protection
Power output: low gear, mid-range, high gear
Battery type: 8 AA alkaline batteries
Battery life: 4 hours to 8 hours of continuous operation depending on frequency of use and output power
           Intermittent working for 6 hours to 10 hours depending on the frequency of use and output power
Working temperature: -10°C-55°C
Size: 16×16×39CM
Weight: 4kg (including battery)

 

 

Packaging & Shipping
PACKING LIST
Serial number Name quantity
  1. 1
Receiver 1
  1. 2
Transmitter 1
  1. 3
Direct signal line 1
  1. 4
Coupling line 1
  1. 5
Ground drill 1
  1. 6
Charger 1
  1. 7
Ground wire 1
  1. 8
A frame 1
  1. 9
A frame cable 1
  1. 10
A-frame probe 2
  1. 11
Launch clamp 1
  1. 12
Receiver clamp 1
 

Direct Connection Coupling Induction Method Cable Fault LocatorDirect Connection Coupling Induction Method Cable Fault Locator

Company Profile

Direct Connection Coupling Induction Method Cable Fault LocatorDirect Connection Coupling Induction Method Cable Fault LocatorDirect Connection Coupling Induction Method Cable Fault Locator

FAQ

Direct Connection Coupling Induction Method Cable Fault Locator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier