• Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
  • Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
  • Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
  • Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
  • Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper

Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper

After-sales Service: Warranty Certificate
Warranty: 12 Months
Power: Electricity
Certification: CE, ISO
Customized: Customized
Transport Package: Wooden Case Filled with Foam
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
XHHV535-4TV
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
100 Pieces /Year

Product Description

 

Product Description

XZH TEST  Vehicle-mounted high-voltage pulse generator is designed for 36kV and below underground cable fault detection. 

 

High voltage 2550 J surge generator is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 36kV.

 

It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults.

The high-voltage pulse generator fully complies with DL/T846-2016 "General Technical Conditions for High Voltage Test Equipment" and DL/T474-2017 "Guidelines for the Implementation of Field Insulation Tests". It is mainly used for impact discharge and withstand voltage tests in low and high voltage cable fault tests.


Features
★ With over-current, over-voltage, over-heat automatic protection function;
★ It has dual 1.5-level pointer meter display for current and voltage, which is intuitive and clear; whether the fault point is fully released
The electricity is clear at a glance, and the discharge process is reflected in real time;
★ With zero start protection, it is safer and more reliable;
★ Uniform and controllable high-voltage pulse output;
★ High-voltage side voltage measurement, real-time and accurate;
★ Unique high-voltage measurement design, in the stop state, it will automatically release the internal capacitance of the device;
★ The discharge time can choose timing and manual modes;
With DC withstand voltage function;
★ Internal installation of high-precision test cable fault sampling waveform module;
★ Humanized design trolley, easy to move;


Technical parameter
   ★ Shock high voltage: 0~36kV optional
   ★ High voltage divider: Voltage accuracy level 1.5
   ★ Built-in capacitor: 4μF
   ★ Output voltage polarity: negative polarity
   ★ Discharge power: 2550J
   ★ Impact time: about 7 seconds for automatic impact, and any control time for manual impact
   ★ Impact power: 2000W
   ★ Volume: 550L×500W×1000H
   ★ Weight: not more than 130kg
   ★ Working power supply: AC 220V±10% 50Hz±2Hz
   ★ Ambient temperature: -20~+50ºC


The composition of the instrument
1. High-voltage pulse generator host: apply high-voltage, high-energy pulse signals to the cable under test;
2. High-voltage output line: connect the high-voltage output end of the host and the cable core under test;
3. Ground wire: high voltage ground, safety ground, sampling ground and discharge rod ground wire;
4. Short wiring: When using the multiple pulse method, the high-voltage flashover output terminal is short-circuited with the multiple pulse input terminal;
5. Power cord: instrument working power cord;
6. Sampler: In the high-voltage flashover method, it receives the signal reflected from the high-voltage signal to the sampling ground;
7. Discharge rod: DC current-limiting discharge or DC short-circuit discharge at the end of the cable under test;
8. Fuse: AC220V power supply system backup fuse.

--------------------------------------------------------------------------------------------------------------------------------------------------------------------
Operation interface introduction
Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper

Panel function description
1. Ammeter: Indicates the magnitude of the current on the low-voltage side.
2. Voltmeter: High voltage output voltage indicating kV meter.
3. High voltage lamp (HV): On means there is high voltage output, off means there is no high voltage output.
4. Power light (Power): After turning on the power switch, the light will be on.
5. Zero light (Zero): Indicates that the pressure regulating knob is in the zero state, and the high pressure can only be started when the zero light is on.
6. Time setting: set the discharge time interval.
7. Power socket (AC220V): instrument working power supply, AC220V connection port;
8. Fuse socket: where the fuse of the AC220V power supply system is installed;
9. Power switch (NO/OFF): "Gear 1" uses AC220V power supply to start the machine, and "Gear 0" turns it off.
10. Single discharge (Single Discharge): When the mode selection key is in single (Single) function, this key is valid.
11. Mode select: It is divided into three modes: withstand voltage (DC), single (Single), and cycle (Cycle). DC is the withstand voltage function. When this function is selected, the cable will be tested for withstand voltage at this time; Single is the manual function. When this function is selected, the voltage will be boosted after the high voltage is started. Press the Single button to manually trigger the impact discharge; Cycle is an automatic function. When this function is selected, the high voltage is started to boost the voltage, and the instrument will automatically trigger the impact discharge for about 5 seconds.
12. Start button (Start): In the zero position state, press the start button, and the high voltage starts at this time, and the high voltage light is on. In the non-zero state, the start high pressure light is off.
13. Stop button (Stop): When the test is completed or an abnormality occurs, press this button to cut off the high voltage output, and at this time, the remaining high voltage of the test will be automatically discharged.
14. Voltage control knob (Voltage control): When this knob is in the zero position, the zero position light is on, and the high voltage can be started. After the high voltage is started, the pressure can be boosted through the pressure regulating knob.

---------------------------------------------------------------------------------------------------------------------------------------------------------
Side panel description
Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper
Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper


1. Safety ground (Safety GND): The ground wire must be used when working to ensure the safe use of the equipment.
2. High voltage ground (HV GND): It must be connected to the root of the ground wire of the cable to ensure good grounding.
3. Sampling ground (Sampling GND): Connect to the root of the ground wire of the cable under test. It can be connected to the root of the cable together with the high-voltage ground. It is used for waveform sampling under flashover conditions. It must be well grounded when in use.
4. Signal ground (Signal GND): When using the multi-pulse method, it needs to be connected (the ground wire of the multi-pulse coupler).
5. High-voltage flashover output (HV Flash OUT): dedicated DC high-voltage output terminal.
6. Multiple Pulse (Multiple Pulse): (Input Input Output Output): When using the multiple pulse method, the high-voltage flashover output terminal and the multiple pulse input terminal are short-circuited with a high-voltage wire (as shown in the figure above), and the high-voltage output wire is connected to the On the multi-pulse output terminal.
7. High-voltage flashover signal (HV Flash Signal): Use double Q lines to connect the machine and the cable fault tester to collect waveforms for flashover, which is only valid during high-voltage flashover.
8. Multiple Pulse Signal: Use double Q lines to connect the machine and the cable fault tester for flashover acquisition of waveforms, only valid for multiple pulses.




We can customize according to what your required.
Welcome you contact us for more information of each equipment.

Detailed Photos

 

Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper


Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper









Welcome you contact us for more information~

 
 

Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper  Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper

Xzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable ThumperXzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable ThumperXzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable ThumperXzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable ThumperXzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable ThumperXzh Test Vehicle-Mounted High-Voltage Pulse Generator 0-36kv Surge Wave Generator Cable Thumper

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now