Customization: | Available |
---|---|
After-sales Service: | Warranty Certificate |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
XHGX507 underground pipeline detector has been used by thousands of users in the power cable test has a high reputation in the field. The company used the latest concepts developed XHGX507 pipeline locator, especially for cable-to-ground insulation failure of fast and accurate positioning, (charged) to find the path, depth positioning.
XHGX507 cable pipe locator is designed based on the electromagnetic induction method and the application of the communication principle. Contains more user-friendly design in use. The large-screen LCD displays the signal strength, and the bars, arrows and voice prompts make it easy for the operator to determine the location of the cable underground and the point of failure. One person can complete all operations.
XHGX507 can be used to find the cable (live or uncharged) path and identification, but also can be used to find the direct buried cable fault. It can complete tasks that were only possible with the past few sets of instruments.
The XHGX507 cable fault comprehensive tester changes the traditional cable fault location concept. It does not require high-voltage test equipment, AC power supply, and waveform analysis. The wiring is simple and clear, and the method of use is easy to learn. In the past, when we searched for the cable path and identified the cable, it was necessary to test the power failure of the cable, and some running cables could not be powered off, so that it can easily solve the problem of finding and identifying the path of the live cable. It can also directly find the path and identification of 50Hz live cables.
1.Receiver
Working frequency: low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), 50Hz
Antenna mode: valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame)
Sound indication: FM tone that changes with signal strength
Current indication: display the effective current value of the cable under test (unit: mA)
Working temperature: -10ºC+55ºC
Battery model: 6 AA alkaline batteries
Power indicator: graphic display
Battery life: continuous work> 8 hours: intermittent work> 16 hours
Size: 70×20×11cm
Weight: 3kg (with battery)
Signal strength indication: ladder diagram, digital range 0-999
Gain control: manual adjustment, dynamic range of 100dB
Detection depth: the maximum detection depth is not less than 5 meters
Maximum detection distance: The cable with good insulation can be up to 15km in the direct connection method
Depth measurement: press the depth key to display three digits, the maximum depth can be measured up to 10 meters
Accuracy: Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m
Depending on the site environment, the shape of the non-concentric lines, the number of adjacent pipelines, and the return current of the soil
2.Transmitter
Working frequency: low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz)
Working mode: direct connection method, coupling method (caliper method), induction method
Matching load: 5 ohms-3000 ohms
Impedance display: five digits
Overheating and overcurrent: automatic protection
Power output: low gear, middle gear, high gear