Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
  • Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • Our Advantages
  • On-site Test
  • FAQ
Overview

Basic Info.

Model NO.
XHXC105
Test Mode
Saved Test
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Degaussing Process
0-100% Automatic Recording and Earsing Time
Temperature
-25 to 50 Degree Centigrade
Transport Package
Wooden Box with Foam Inside
Specification
5.5kg
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
1000pieces/Year

Product Description

 

Product Description

XHXC105 power transformer transformer degaussing instrument is a special equipment to eliminate the residual magnetism hazard after the DC resistance test of large power transformer transformers. It plays an extremely important role in protecting power transformer transformers from the impact of inrush current and safe operation.

Due to the inherent hysteresis of ferromagnetic materials, residual magnetism will remain in the iron core after the voltage ratio and DC resistance measurement of the power transformer. Due to the existence of remanence, when the transformer is put into operation, the remanence of the iron core saturates the iron core of the transformer half a circle, and a large number of harmonics are generated in the excitation current. This not only increases the reactive power consumption of the transformer, but also may cause the relay protector to malfunction. , Causing certain economic losses. Therefore, we must do demagnetization work before the transformer is put into operation to ensure the safe and normal operation of the transformer.

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument


The XHXC105 power transformer transformer degaussing instrument adds an automatic degaussing mode on the basis of the original series of products, so the user does not need to repeat the operation. The size of the LCD module has been increased, and the degaussing time test function has been added to make the display information more abundant. Two-key operation: red selection and reset, green confirm and start, the operation is more convenient. Change the product from the original 30 minutes to less than 4 minutes from the demagnetization time.

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument
Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

 

 

Product Parameters

 
Degaussing current 5A, 1A, 200mA, 5mA can be customized
Degaussing method manual, automatic
Degaussing time manual 4min/time, automatic 9min/time
Degaussing effect   more than 90%/time
Degaussing progress 0~100%
Power supply AC 220V±10%
Power frequency 50Hz±1Hz
Ambient temperature -25ºC~50ºC
Environmental humidity ≤90%

★ Adopt patented technology-DC frequency conversion attenuation principle;
★ The three-phase transformer can achieve the purpose of demagnetization only by demagnetizing phase B;
★ With automatic steady flow judgment, 16-bit AD data acquisition and processing functions;
★ With manual/automatic degaussing mode, a total of 5 degaussing modes;
★ Fast degaussing speed-single time increased from 30min to no more than 4min;
★ Obvious degaussing effect-increased from 80% to more than 90% in a single time;
★ The current wire for DC resistance test can be used directly, which is convenient for matching with DC resistance test;
★ Adopt Chinese interface, clear interface, real-time display of degaussing progress;
★ It is suitable for removing residual magnetism before large power transformers and transformers of 35kV and above are put into operation; especially for large-capacity transformers with voltage levels of 330kV and above;
★ The product is small in size and light in weight, which is very suitable for on-site use.

Company Profile

XZH TEST is a professional cable fault detection equipment manufacturer. We are a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.

Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of testing equipment.

 

What we can do

We have the ability to innovate new products and technologies.

We can provide complete system solutions for your project.

We provide online and offline practical and theoretical training.

We provide instrument repair and calibration.

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

Certifications


Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

Packaging & Shipping

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

Our Advantages

 

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

On-site Test

Automatic Power Transformer Demagnetization Device Transformer Degaussing Instrument

FAQ

1. Are you a trading company or a manufacturer?
We are a professional manufacturer with more than 10 years of experience. We can strictly control the quality of parts and finished products.

2. What is the delivery time and inventory?
If our best-selling products are in stock, it will be 5-8 working days for shipment. But for mass production and customized production, the time will take 2-4 weeks.

3. What are your payment terms?
Payment ≤ USD 2000, 100% T/T prepayment. Orders over USD 2000 can be negotiated.

4. How long is your product warranty?
We provide 1 year warranty for the equipment.

5. How do you ensure quality?
The product links include R&D, manufacturing, commissioning and technical support, following strict and scientific management principles. Therefore, we can support strong production and R&D capabilities, and can produce high-quality products at competitive prices to meet customers' high requirements.

6. What support can I get?
We will provide training support, marketing support, technical support and supply chain support. You can contact us for more information.

7. Where is your factory? Can I visit your factory?
We are located in Xi'an, Shaanxi, China. We are close to Xi'an Xianyang International Airport, which is about 2 and half hours by plane from Shanghai and Guangzhou. All customers from all over the world are welcome to visit us.

8. How to become your dealer?
Every company interested in power system instruments can contact us without hesitation, including website letters, emails, telephones, etc. We will contact you quickly according to your company information and cooperation intentions.


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier