Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
  • Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Find Similar Products
  • Overview
  • Product Description
  • Packing list
  • Company Profile
Overview

Basic Info.

Model NO.
XHHV535-4TSB
Frequency Range
50Hz
Type
Pulse Signal Generator
Channel
3
Display
TFT
Transport Package
Wooden Case
Specification
81*60*106
Trademark
XZH TEST
Origin
Shaanxi

Packaging & Delivery

Package Size
81.00cm * 60.00cm * 106.00cm
Package Gross Weight
190.000kg

Product Description

Product Description
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
The XHHV535-4TSB cable fault location system is used to detect the main insulation fault of power cables with voltage levels of 35kV and below and calibrate the cable length. This system consists of two parts: a cable fault tester and a high-voltage pulse generator.

The cable fault tester adopts a simple operating software interface, centralized control by a single-chip microcomputer, touch-type operation, and a built-in large-capacity lithium-ion battery. It is stable, reliable, and easy to use. An independent power supply and power supply system are used to prevent power supply interference during impact discharge.

This cable fault test system is suitable for low-resistance, short-circuit, open-circuit and broken wire faults of power cables, high-frequency coaxial cables, street light cables, and underground wires of various materials with different cross-sections and different media, as well as high-resistance leakage and high-resistance flashover faults.
 
HV Pulse generator parameters:

Impulse voltage: 0~32kV,0~16kV,0~8kV(Adjustable)
High voltage partial pressure: 1.5 level
Built-in capacitor: 4μF/32kV,16μF/16kV,64μF/8kV Adjustable three-speed adjustment 
Discharge power: both are 2048J
Impact time: about 5 seconds for automatic impact, arbitrary control time for manual impact 
Surge power: 2KVA
Working power supply: AC 220V±10% / 50Hz±2Hz(60Hz can be customized)
Ambient temperature: -20~+50ºC
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Cable fault pre-locator parameters:

• Sampling frequency: 1MHz~400MHz;
• Low voltage pulse amplitude: 300V±15%;
• Distance measurement range: ≥120km;
• Test range: 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km;
• Pulse width: 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS;
• Minimum resolution: 0.07m;
• Test blind area: ≤10m;
• Measurement error: ≤±(0.5%×L+1m), L is the cable length;
• Working power supply: built-in 10.4AH lithium battery; charging time is about 2 hours, working time is 5 hours
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method
Packing list

Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method

 

Company Profile

Customized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc MethodCustomized 35kv Cable Fault Location System Pulse Generator with Tdr Arc Method

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier