Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: Warranty Certificate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
  • Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)
Find Similar Products

Basic Info.

Model NO.
XHJS1000B
Trademark
XZH TEST
Origin
China Xi′an
HS Code
854320100
Production Capacity
100 Pieces /Year

Product Description

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

 

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

The XHJS1000 inter-frequency dielectric loss tester is a high-precision test instrument for testing the dielectric loss tangent and capacitance of various high-voltage power equipment in power plants substations. The instrument is an integrated structure, built-in dielectric loss test bridge, variable frequency voltage regulator, step-up transformer and SF6 high stability standard capacitor. The test high voltage source is generated by the inverter inside the instrument and is used for testing the test object after being boosted by the transformer. The frequency can be changed to 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz. The digital notch technology is used to avoid the interference of the power frequency electric field to the test, which fundamentally solves the problem. The problem of accurate measurement under strong electric field interference. At the same time, it is suitable for the occasion of power supply detection after power failure. The instrument is equipped with an insulating oil cup and a temperature control device to test the dielectric loss of the insulating oil.

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

 

Specifications:

1 Conditions of Use -15ºC∽40ºC RH<80%
2 Anti-interference principle Frequency conversion method  
3 Power supply AC 220V±10% generator allowed
4 High voltage output 0.5KV∽10KV Every 0.1kV
Accuracy 2%  
Maximum current   200mA  
Capacity 2000VA  
5 Self-excited power supply AC 0V∽50V/15A 50HZ,60HZ single frequency
45HZ/55HZ   47.5HZ/52.5HZ
55HZ/65HZ   57.5HZ/62.5HZ
Automatic double frequency conversion
6 Resolution tgδ: 0.001% Cx: 0.001pF
7 Accuracy △tgδ:±(reading *1.0%+0.040%)  
△C x :±(reading *1.0%+1.00PF)    
8 Measuring range tgδ unlimited
C x 15pF < Cx < 300nF
10KV Cx < 60  nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT ratio range 10∽10000  
  CVT ratio accuracy 0.1%  
  CVT ratio resolution 0.01  
10 Dimensions (host) (mm) 350(L)×270(W)×270(H)  
  Dimensions (Accessory Box) (mm) 350(L)×270(W)×160(H)  
11 Memory size 200 groups support U disk data storage  
12 Weight (Host) 22.75Kg  
13 Weight (Accessory Box) 5.25Kg  

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)

 

Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)Xhjs1000b Dielectric Loss Tester (Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set)













 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier