10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: Warranty Certificate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
  • 10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
Find Similar Products

Basic Info.

Model NO.
XHJS1000B
Transport Package
Wooden
Specification
420mm× 250mm× 340mm
Trademark
XZH TEST
Origin
China Xi′an
HS Code
854320100
Production Capacity
100 Pieces /Year

Product Description

 

XHJS1000B Transformer Motor Insulation Power Factor Tester/ Tan Delta Test Set
10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
XHJS1000B Different Frequency Automatic Dielectric is a high-precision instrument, which can be applied to automatically measure electrical loss tangent () and capacitance Insulation resistance of all kinds of high voltage electrical equipment on the spot of power plants, substations,laboratory, etc. The instrument is an integrated structure with a dielectric loss test bridge, avariable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor. High voltage source inverter test generated inside the instrument, the transformer voltage for sample test.

If the frequency is 50Hz,47.5Hz\52.5Hz,45Hz\55Hz,60Hz,57.5Hz\62.5Hz,55Hz\65Hz, the digital notch filter is used to avoid the interference of the powerfrequency electric field to the test, which solves the problem of accurate measurement under the strong electric field interference. At the same time, the utility model is suitable for the occasions that the generator is used for power supply after the power cut. The instrument with insulation cup can test the dielectric loss of insulating oil.
10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
 
1 Conditions of Use -15ºC∽40ºC RH<80%
2 Anti-interference principle Frequency conversion method  
3 Power supply AC 220V±10% generator allowed
4 High voltage output 0.5KV∽10KV Every 0.1kV
Accuracy 2%  
Maximum current   200mA  
Capacity 2000VA  
5 Self-excited power supply AC 0V∽50V/15A 50HZ,60HZ single frequency
45HZ/55HZ   47.5HZ/52.5HZ
55HZ/65HZ   57.5HZ/62.5HZ
Automatic double frequency conversion
6 Resolution tgδ: 0.001% Cx: 0.001pF
7 Accuracy △tgδ:±(reading *1.0%+0.040%)  
△C x :±(reading *1.0%+1.00PF)    
8 Measuring range tgδ unlimited
C x 15pF < Cx < 300nF
10KV Cx < 60  nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT ratio range 10∽10000  
  CVT ratio accuracy 0.1%  
  CVT ratio resolution 0.01  
10 Dimensions (host) (mm) 350(L)×270(W)×270(H)  
  Dimensions (Accessory Box) (mm) 350(L)×270(W)×160(H)  
11 Memory size 200 groups support U disk data storage  
12 Weight (Host) 22.75Kg  
13 Weight (Accessory Box) 5.25Kg  

 

10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester

10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester

10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester10kv Automatic Power Transformer Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Factor Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier