Customization: | Available |
---|---|
After-sales Service: | Warranty Certificate |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
General features | |
Portable cable fault location system | |
Graphical interface | Graphical interface, more intuitive and easy to operate. |
Operation | Turn and click a single knob (jog dial) on the control unit |
Data management | General database |
Data Synchronization | Universal Serial Bus |
Control unit | |
Display | Industrial grade TFT color panel with LED backlight |
Anti-glare | have |
Multi-touch | have |
LCD size | 10" |
Aspect Ratio | 16:9 |
Resolution | 1024 x 768 Full HD |
Brightness | 450 cd/m² |
Safety | |
Adaptability | CE Compliance;EN 61010,EN 50191,VDE 0104,VDE 015,DGUV 203-034(BGI 891) |
Discharge and grounding devices | 72kJ, equivalent to the energy stored in a 10µF capacitor charged to 120kV DC fast charge: discharge time constant < 1 second |
System Status | Real-time monitoring and indication |
Intrinsically safe | Ground immediately when there is a power outage |
F-U safety interlock | Operating voltage connection monitoring (high voltage circuit) |
F-Ohm Safety Interlock | Operational earth connection monitoring (high voltage circuit) |
Security Features | Front panel: power on/off, lockout button switch, emergency stop, residual pressure indicator light, high voltage switch; Control unit: Knob (jog dial) |
Safety devices | System grounding status indicator, power input protection device, high voltage room monitoring through door contact, external safety device |
Power input monitoring | Overvoltage protection, undervoltage protection, residual current device (RCD) |
Defining Wiring | There is a switchboard inside the system |
System function | |
1.Use DC or high-voltage pulse to make the cable fault point flash over and discharge 2.Use the traveling wave reflection principle to make a rough measurement of all types of cable main insulation faults |
|
I,High voltage surge generator | |
Output mode | DC, Single, Cycle |
Output voltage | 8kV,16kV,32kV |
Built-in capacitor | 64uF,16uF,4uF |
Discharge energy | 2048J @ each voltage level |
Impact power | 2000VA |
Impulse rate | Automatic impact for about 6 seconds, manual impact for any control time |
Surge voltage levels switch | Manual |
Voltage adjustment type | Continuous |
Indication | High-voltage side voltage metering, indication of output voltage and current in real time |
Operating modes switch | Manual |
Coupler | Built-in multiple pulse sampling box |
Safe protection | With zero start protection function, safe and reliable |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device |
Working power | AC 220V±15% ,50Hz±2Hz(60Hz) |
DC withstand voltage testing | Output voltage adjustable and indication range 0-32kV, output current indication range 0-20A |
Burn current | Fault conditioning (burning) with current up to 60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV |
Safety | Over-voltage, Over-current, Overheating protection. Automatic discharge after operation |
Protection rating | Not lower than IP54 |
Dimensions(mm) | 534L×444W×805H mm |
Total weight | Not more than 130kg |
II,TDR cable fault locator | |
Test method | Low voltage pulse, Impulse current, Impulse voltage, ARC multipls pulse |
Sampling rate | 1MHz~400MHz |
Pulse output | Unipolar |
Pulse Amplitude | 300V |
Pulse width | 0.15μS/0.30μS /0.60μS/1.20μS/2.4μS/5.0μS/7.5μS/10μS |
Measurement scope | ≥120km |
Measurement range | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km |
Minimum resolution | 0.07m |
Measurement error | ≤±(0.5%×L+1m),L is cable length |
Signal gain | 0…100%,adjustable |
Propagation speed | 10…999.9m/µs |
Output Impedance | Automatic match |
Trigger | Automatic continute |
Result analysis | Automatic measure fault distance |
Working conditions | temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg |
IV Test cables | |
(Note: Due to the existence of 35kV high voltage, special high voltage cables are made and should be kept away from the site during operation.) | |
High voltage output cable | core wire 2.5mm2 red, withstand voltage 50kV DC, with shielding layer, outer diameter 14mm, length can be customized according to customer's requirements, including installation of large spool. |
Ground cable | grounding 3-column - main core 16mm2 transparent color, branch 2.5mm2, length can be customized according to customer's requirements, including installation of small spool. |