Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester
Test Region
Forming Cable
Cable Type
Shielded
Power
Electricity
Certification
CE, IEC
Customized
Customized
Color
Black
Transport Package
Wooden Case
Specification
83*64*107
Trademark
XZH TEST
Origin
Shaanxi
Product Description
Portable medium voltage cable fault locating system
The XHHV535-4TSB cable fault location system is used to detect the main insulation fault of power cables with voltage levels of 35kV and below and calibrate the cable length. This system consists of two parts: a cable fault tester and a high-voltage pulse generator.
The cable fault tester adopts a simple operating software interface, centralized control by a single-chip microcomputer,touch-type operation, and a built-in large capacity lithiumion battery. It is stable, reliable, and easy to use. An independent power supply and power supply system are used to prevent power supply interference during impact discharge.
This cable fault test system is suitable for low-resistance, short-circuit, open-circuit and broken wire faults of power cables,high-frequency coaxial cables, street light cables, and underground wires of various materials with different cross-sections and different media, as well as high-resistance leakage and high-resistance flashover faults.
High Voltage Pulse Generator XHHV535-4TSB
Impulse voltage: 0~32kV,0~16kV,0~8kV(Adjustable) High voltage partial pressure: 1.5 level Built-in capacitor: 4μF/32kV,16μF/16kV,64μF/8kV Adjustable three-speed adjustment Discharge power: both are 2048J Impact time: about 5 seconds for automatic impact, arbitrary control time for manual impact Surge power: 2KVA Working power supply: AC 220V±10% / 50Hz±2Hz(60Hz can be customized) Ambient temperature: -20~+50ºC
Cable fault pre-locator parameters:
• Sampling frequency: 1MHz~400MHz;
• Low voltage pulse amplitude: 300V±15%;
• Distance measurement range: ≥120km;
• Test range: 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km;
• Pulse width: 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS;
• Minimum resolution: 0.07m;
• Test blind area: ≤10m;
• Measurement error: ≤±(0.5%×L+1m), L is the cable length;
• Working power supply: built-in 10.4AH lithium battery; charging time is about 2 hours, working time is 5 hours
XHDD503E cable fault pinpointer is suitable for low-resistance, short-circuit, open-circuit, and broken-wire faults of various
power cables, coaxial cables, and low-voltage cables and wires with different voltage levels, different cross-sections, and
different media, as well as leakage and flash over high-resistance faults.
Main parameters:
Sound channel-Bandwidth
l All-pass: 100Hz~1600Hz.
l Low pass: 100Hz~300Hz.
l High pass: 160Hz~1600Hz.
l Band pass: 200Hz~600Hz.
Channel adjustment: 8 levels of sound, magnetic and voltage.
Sound output: Gain: 16 levels (0-112dB), Impedance: 350Ω
Detection range: 0.00-99.99ms, 75mV-75V
Detection accuracy: Positioning: ≤0.1m; Step voltage: ≤0.5m; Path: ≤0.5m
Working power supply: 4*18650 standard lithium battery.
Standby time: more than 8 hours
Ambient temperature: -25-65ºC; Relative humidity: ≤90%
Volume dimensions: 428L×350W×230H
Overall weight: 7kg