| Function |
Insulation resistance test, voltage test |
| Baseline conditions |
23ºC±5ºC,75%rh below |
| Rated voltage |
250V,500V,1000V,2500V,5000V,10KV |
| Insulation resistance range |
0.01MΩ~2TΩ |
Resolution:0.01MΩ |
| Measuring voltage (V) |
Rated voltage×(1±10%) |
| DC voltage range |
0~1000V |
Resolution: 0.1V |
| AC voltage range |
0~750V |
Resolution: 0.1V |
| output short circuit current |
≥5mA@10KV |
| Absorption Ratio and Polarization Index Measurements |
with |
| power supply |
12.6V Rechargeable lithium battery |
| Backlight |
Controllable gray and white screen backlight, suitable for use in dark places |
| display mode |
4-digit large LCD display, gray and white screen backlight |
| LCD display size |
108mm×65mm |
| Meter size |
length width height:277.2mm×227.5mm×153mm |
| USB interface |
With USB interface, software monitoring, storage data can be uploaded to the computer, save and print |
| communication line |
USB 1 communication line |
| test lead |
High voltage bar red 3 meters, high voltage test line black 1.5 meters, green line 1.5 meters |
| data storage |
500 groups, flashing "FULL" symbol indicates that the storage is full |
| Data access |
Data access function: "MR" symbol display |
| Overflow display |
Over range overflow function: "OL" symbol display |
| Alarm function |
If it is greater than or less than the set value, an alarm prompt will be issued. |
| Power consumption |
Standby: 30mA Max (backlight off), turn on the backlight: 42mA Max, Measurement: 200mA Max (backlight off) |
| Weight |
2750g |
| battery voltage |
Low battery voltage, showing low battery symbol |
| Automatic shut-down |
The meter shuts down after 15 minutes of inactivity |
| Insulation resistance |
≥50MΩ(between measurement line and enclosure) |
| Voltage withstand |
AC3kV/50Hz 1min |
| Operating temperature and humidity |
-10ºC~+50ºC<85%RH |
| Storage temperature and humidity |
-15ºC~+55ºC<90%RH |
| Suitable for safety regulations |
IEC61010-1,IEC1010-2-31,IEC61557-1/5,IEC60529(IP54) |