Customization: | Available |
---|---|
Warranty: | 1 Year |
Connectors: | USB |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product name | Model | Main function |
High voltage pulse generator | XHHV535-4TS | ★ impulse high voltage: 0 ~ 32kv, 0 ~ 16Kv and 0 ~ 8Kv three gear regulation ★ Short circuit current: 0-60mA ★ high voltage partial voltage: voltage accuracy level 2.5 ★ built in capacitor: 4 μ F/32kV,16 μ F/16kV,64 μ F / 8KV three gear regulation ★ discharge power: 2048J ★ Output voltage polarity: negative polarity ★ impact time: automatic impact for about 5 seconds, manual impact for any control time ★ Overcurrent protection: 9A (greater than 5s) low-voltage side ★ impact power: 2000W ★ weight: about 130kg |
Cable fault pre locator | XHGG502A | ★ Display: 10.1-inch touch screen,Windows system; ★ Function: Test cable wave speed, cable length and fault distance; Automatic testing range setting, automatic waveform analysis to display testing distance; Powerful data processing and massive test waveform storage. ★Testing methods: Low voltage pulse method, high voltage flashover method, ARC multiple pulse method ★Power supply : Equipped with a 5200mAH lithium battery for power supply; Charging AC110V~240V, 50Hz/60Hz ★Sampling frequency: 1MHz~400MHz; ★Low voltage pulse amplitude: 300V ± 15%; ★Distance measurement range: ≥ 120km; ★ Pulse width: 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS; ★ Minimum resolution: 0.07m; ★ Test blind spot: ≤ 10m; |
Cable fault pinpointer | XHDD503C | By Acoustic-magnetic synchronization method to accurately locate the fault point of the cable and detect the path , with powerful background noise reduction(BNR) and compass indication functions |
underground cable pipeline locator (cable route tracer) |
XHGX507C | ★ Function: pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding ★Scope of application: detection and patrol of various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline detection of power supply and other departments, ★ Frequency range: Active detection frequency: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz RF passive detection frequency band: center frequency is divided into 32.7kHz, 65.6kHz, 81.9kHz, 197kHz ★ Pipeline measurement depth: 0-20m ★Test method: DC method, induction method, coupling method |
1) Single chip controled computer, keyboard operation mode, strong anti-interference ability;
2)System functions: fault distance measurement, fault pinpoint location, propagation speed test, cable path search, buried depth detection;
3)Test methods: low-voltage pulse, flashover method, audio method, acousto-magnetic synchronization method, valley method, peak method, electromagnetic induction method, etc.;
4)Test range: test distance: >120km, detection depth: 2-5m;
5)Measurement accuracy: Rough measurement error: ±10m (absolute value) or 1% (relative value), fine measurement error: ±0.2m (fixed point, path, depth);
6)Sampling frequency: 1-400MHz, minimum resolution 0.5m (100m/us)
7)Sampling method: automatic continuous sampling, never miss any discharge waveform.
8)Low voltage pulse: Width: Adaptive Amplitude: 400Vpp
9)Output power: path power: 100W
10)Shock high voltage: three voltage 8/16/32kV adjustable
11)Short circuit current:0~320mA
12)Burn through power:0~2048J
high voltage pulse generator -----XHHV535-4TS
high voltage surge generator XHHV535-4TS | Surge voltage levels and adjustment ranges |
Level 1 : 0-8KV Level 2: 0-16KV Level 3: 0-32KV |
High voltage divider: | Voltage Accuracy 1.5 grade | |
Inside capacitor: | 4μF/32kV,16μF/16kV, 64μF/8kV | |
Surge energy: | 2048J | |
Surge power: | 2KVA | |
Operating mode | Single trigger/cycle/DC | |
Impact time | about 5 seconds for automatic impact, arbitrary control time for manual impact | |
Safe protection | With zero start protection function, safe and reliable | |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A |
|
Burn current | Up to 160mA | |
Connecting cable | High voltage output cable: 5m, Power supply cable: 1.8m, Protective earthing cable: 3m | |
Safety | Overvoltage, Over-current, Overheating protection. Automatic discharge after operation. |
|
Protection rating | Not lower than IP54 | |
GW | 130kg |
ARC Cable Fault pre-locator XHGG502A |
Pre-location method | LV TDR (low voltage pulse method/ impulse reflection method) |
HV TDR(high voltage flashover method /single impulse method ) | ||
ARC (multiple impulse arc reflection method) | ||
ICE (impulse current method) DECAY (voltage decay method) |
||
Automatically test velocity speed | ||
Display | 10.1 inch industrial-grade computer control, touch operation mode | |
System | Windows operating, automatic generate test reports. | |
Function | Speed, resistance, distance measurement | |
Sampling frequency | 1MHz~400MHz | |
Low voltage pulse amplitude | 300V±15% | |
Pulse width | 0.15uS/0.30uS/0.60uS/1.20uS/2.4uS/5.0uS/7.5uS/10uS; | |
Measuring distance | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km/120km; | |
Reading resolution | 0.07m; | |
Test accuracy | ≤±(0.5%×L+1m), L is the cable length; | |
Cable length choice | 100m/300m/500m/1km/3km/5km/10km/25km/50km/100km | |
Pulse coupler withstand voltage | 35kV DC | |
Test blind zone | ≤10m | |
Data storage | Stores more than 8,000 records of low-voltage pulse and high-voltage flashover waveforms, and more than 250 records of multiple pulse waveforms. | |
Power supply | charging AC110V~240V, 50Hz/60Hz; Built-in 5200mAH lithium battery power supply; charging time is about 2 hours, working time is more than 5 hours; |
|
Communication | With standard USB interface | |
Working conditions | Temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg; | |
Volume and weight | Cable fault tester L358mm×W284mm×H168mm-4.7kg; Pulse coupler L430mm×W380mm×H220mm-10kg. |
1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
2 | Channel gain | 8 levels adjustable. |
3 | Magnetic channel gain | 8 levels adjustable. |
4 | Output gain | 16 levels (0~112db) |
5 | Output impedance | 350Ω |
6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
7 | Path identification accuracy | less than 0.5m. |
8 | Power supply | 4*18650 standard lithium batteries. |
9 | Standby time | more than 8 hours. |
10 | Volume | 428L×350W×230H |
11 | Weight | 6.5kg. |
12 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding |
Power supply | 8.4V large capacity rechargeable lithium battery |
Input method | Built-in receiving coil, flexible caliper, A-frame (optional function) |
Receiving frequency | Active detection frequencies: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz RF passive detection frequency band: center frequencies are 32.7kHz, 65.6kHz, 81.9kHz, 197kHz |
Pipeline detection mode | Broad peak method, narrow peak method, valley method |
Pipeline detection Detection range |
Direct connection method: Generally, the cable length can reach 0~20 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth. Coupling method: Generally, the cable length can reach 0~10 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth. Induction method: suitable for cables buried less than 2m deep |
measurement depth | 0-20m |
Cable identification Detection range |
Direct connection method: can identify signals with loop resistance of 0Ω~8kΩ (usually can reach cable length of 0~20 kilometers, mainly determined by ground resistance and cable resistance) Coupling method: can identify signals with loop resistance of 0Ω~1kΩ; (generally, the cable length can reach 0~6 kilometers, mainly determined by the ground resistance and cable resistance) |
liquid crystal | 4.3-inch LCD color screen (high brightness screen), visible in sunlight |
Size | About 350mm (length) × 155mm (width) × 700mm (height) |
Weight | About 2kg |
Coil inner diameter | φ200mm (larger diameter can be customized as needed) |
Working temperature and humidity | -10ºC~40ºC; below 80%Rh |
Suitable for safety regulations | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, pollution degree 2 |
Function | Multiple frequency signal transmission modes |
power supply | 10.8V large capacity rechargeable lithium battery |
Output method | Direct connection method, coupling method, induction method |
Output frequency | 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz |
Output Mode | Automatic identification, automatic identification according to different accessories |
Output Power | 15W max, 9 levels adjustable |
impedance | Fully automatic real-time impedance matching and protection function |
Direct output voltage | 150Vpp max |
Circuit Protection | With overload and short circuit protection |
liquid crystal | 5-inch LCD color screen |
Touch | Yes, capacitive touch |
Instrument size | About 320mm (length) × 275mm (width) × 145mm (height) |
quality | Transmitter weight: about 3.85kg; Transmitter clamp weight: about 1.18kg |
charger | DC 11.1V 3A |
Launching clamp size | Length, width and thickness: 297mm×194mm×39mm |
Inner diameter of firing clamp | φ125mm |
Transmitter cable length | 3m |
Test line | Red test line 3m, black test line 3m |
Connection interface | USB port, DC port, aviation socket |
Stress resistance | The transmitter adopts an integrated special tool box design, and the box can withstand a pressure of about 200kg. |
Pressure resistance | AC 3700V/rms (between the top and bottom of the instrument box) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1 (CAT 300V, CAT IV 150V, pollution degree 2) |