Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
  • Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
XHEP701A
Transport Package
Wooden Case
Specification
27kg
Trademark
XZH TEST
Origin
Shaanxi
Production Capacity
20000

Product Description

Product Description
Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A
XHEP701A Different frequency ground resistance tester
The digital large-scale ground grid ground resistance tester, also known as the power frequency ground resistance tester, ground resistance meter, etc., is a common instrument for testing and measuring ground resistance. It adopts a new variable frequency AC power supply, dual-frequency measurement technology, super large touch color screen and microprocessor technology to meet the requirements of two-wire, three-wire and four-wire test impedance, and can measure soil resistivity, step voltage, distributed potential, contact voltage, current phase angle and other parameters. It is suitable for telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc., and meets the standards of power substations and lightning protection device detection instruments. The instrument test is accurate, fast, simple, stable and reliable. The maximum open circuit voltage output of this tester can reach 400V, and the maximum short-circuit current can reach 5A. Microprocessor control and automatic dual-frequency technology can accurately measure and calculate the ground impedance value under 50Hz power frequency under strong interference, and the large screen display is clear at a glance. 100 sets of data can be stored at the same time, and the resistance measurement range is: 0.030Ω~2000Ω. The measured data can be printed out through a thermal printer. The digital large-scale ground grid ground resistance tester consists of a host, test wire, ground rod, etc., and has the functions of reading, reviewing, saving, and printing historical data.

Xhep701A Digital Power Frequency Ground Resistance Meter 400V/3A

Product Parameters
achievement able
Ground impedance measurement, soil resistivity measurement, step voltage measurement, distributed potential measurement, contact
voltage measurement
Ground impedance
0.030~1.999Ω
Accuracy: ±0.5%FS±5dgt
Resolution: 0.001Ω
2.00~19.99Ω
Resolution: 0.01Ω
20.0~199.9Ω
Resolution: 0.1Ω
200~2000Ω
Resolution: 1Ω
Soil resistivity
0.000~9.999Ωm
ρ=2πaR X (Note 3)
Resolution: 0.001Ωm
10.00~99.99Ωm
Resolution: 0.01Ωm
100.0~999.9Ωm
Resolution: 0.1Ωm
1000~9999Ωm
Resolution: 1Ωm
10.0~99.9KΩm
Resolution: 0.1KΩm
100~999KΩm
Resolution: 1KΩm
Step voltage, distributed potential, contact voltage
0.0 0 0~ 1.999KV
U=Z*Is (Note 4)
Resolution: 0.001KV
2.00~19.99KV
Resolution: 0.01KV
20.0~199.9KV
Resolution: 0.1KV
200~20000KV
Resolution: 1KV
Impedance angle measurement
0~359.9°
 
Resolution: 0.1°
radian
0~6.283
 
Resolution: 0.001
Rated measuring power
2000W
Anti-interference ability
Anti-power frequency 50Hz voltage 50V
Baseline conditions
23 ºC± 5 ºC, 70%rh or less ( auxiliary grounding resistance 20Ω ± 10% , voltage to ground < 10V)
electricity source
AC 220V 10A (50Hz)
back Light
Adjustable backlight brightness
Measurement method
Four-wire test, three-wire test, two-wire test
Measurement method
Ground impedance: rated current method,
Short circuit current output
1A , 2A , 3A , 4A , 5A (5 settings )
Soil resistivity electrode spacing range
Can be set from 1m to 100m
Test frequency
45Hz , 55Hz , automatic dual frequency optional
Short circuit maximum current
AC 5A ± 10% sine wave
No-load maximum voltage
AC 400V ± 10% sine wave
Display Mode
7- inch touch color screen
touch screen
yes
Measurement Indication
Measurement progress display, measurement prompt animation display
Instrument size
Length, width and height: 540mm × 440mm × 210mm
Standard test line length
Red 15m , Black 15m , Yellow 10m , Green 10m , Yellow 1.5m , Green 1.5m , 1 each
Auxiliary ground rod
800mm 2 pieces 200mm 2 pieces
Measuring time
Ground impedance: about 1 minute / time
Print
Built-in thermal printer
Printing paper specifications
57*40mm
Data storage
100 groups, "Save successfully ! " storage indication, display "Save failed , space is full ! " characters indicate that the
storage is full
Data review
have
Overflow Display
Over-range overflow function: " OL " symbol displayed
Automatic shutdown
none
achievement Consumption
Standby : <110W
Measured: 2000W
quality quantity
Instrument: 27 kg
Test lead, auxiliary ground rod, instrument bag: 5.5kg
Working temperature and humidity
-10 ºC~ 40 ºC; 80%rh or less
Storage temperature and humidity
-20 ºC~ 60 ºC; 70%rh or less
Insulation resistance
10MΩ or more ( 500V between circuit and housing )
Resistance Pressure
AC 3700V/rms ( between circuit and housing )
Electromagnetic properties
IEC61010-4-3 , radio frequency electromagnetic field ≤ 1V/m
Suitable for safety regulations
IEC61010-1 , IEC1010-2-31 , IEC61557-1,5 , IEC60529 (IP54) , pollution level 2 , CAT III 300V