High voltage surge generator XHHV535 series
Surge voltage generators enable accurate location of high resistance, low resistance and intermittent faults on high, medium and low voltage cables.High surge voltage include three gears, 0-8kV, 0-16kV and 0-32kV.
XHHV535-2TS | XHHV535-4TS | XHHV535-6TS | XHHV535-8TS | |
Mains supply | AC220V ±10% | AC220V ±10% | AC220V ±10% | AC220V ±10% |
Option | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer |
Mains frequency | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% |
Max. Power consumption(at short circuit) | 2000VA | 2000VA | 3500VA | 3500VA |
Max. output voltage | 32kV | 32kV | 32kV | 32kV |
Output voltage range | 0-8kV 0-16kV 0-35kV |
0-8kV 0-16kV 0-35kV |
0-8kV 0-16kV 0-35kV |
0-8kV 0-16kV 0-35kV |
Max. surge energy | 1225J@each voltage level | 2048J@each voltage level | 3072J@each voltage level | 4096J@each voltage level |
Impulse frequency | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device |
Burn current(DC output current) | Fault conditioning (burning) with current up to 60 mA @ 32 kV,When the voltage is low, the current will be larger |
Fault conditioning (burning) with current up to 60 mA @ 32 kV,When the voltage is low, the current will be larger |
Fault conditioning (burning) with current up to 105mA @ 32 kV,When the voltage is low, the current will be larger |
Fault conditioning (burning) with current up to 105mA @ 32 kV,When the voltage is low, the current will be larger |
Precision of the KV meter | 1.5 | 1.5 | 1.5 | 1.5 |
operating temperature range | -25~+65ºC | -25~+65ºC | -25~+65ºC | -25~+65ºC |
Over current protection | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side |
Over temperature protection | 105ºC | 105ºC | 105ºC | 105ºC |
Safety system | Over-voltage Over-current Overheating protection Automatic discharge after operation |
Over-voltage Over-current Overheating protection Automatic discharge after operation |
Over-voltage Over-current Overheating protection Automatic discharge after operation |
Over-voltage Over-current Overheating protection Automatic discharge after operation |
Protection rating | Not lower than IP54 | Not lower than IP54 | Not lower than IP54 | Not lower than IP54 |
Net weight(kg) | Not more than 130kg | Not more than 130kg | Not more than 140kg | Not more than 150kg |
Packaging: Wooden case filled with foam
Shipping: by Air, Sea, Express, etc.
Shipping time: 7-15 days if it's in stock.