Customization: | Available |
---|---|
After-sales Service: | Warranty Certificate |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
System function | ||
1.Use DC or high-voltage pulse to make the cable fault point flash over and discharge 2.Use the traveling wave reflection principle to make a rough measurement of all types of cable main insulation faults 3.Use the acoustic-magnetic synchronization method to make a precise measurement of all types of cable main insulation fault |
||
I,High voltage surge generator XHHV535-2L | ||
Output mode | EMP(impulse), DC(withstand voltage) |
|
Output voltage | 0-32kV | |
Built-in capacitor | 2μF | |
Discharge energy | Max. 1024J | |
Impact power | 250W peak | |
Impulse rate | Automatic impact for about 6 seconds | |
Surge voltage levels switch | Manual | |
Voltage adjustment type | Continuous | |
Indication | High-voltage side voltage metering, indication of output voltage and current in real time | |
Operating modes switch | Manual | |
Minimum Output current in DC mode | 7.5mA at 32kV | |
Safe protection | With zero start protection function, safe and reliable | |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
Working power | AC 220V±15% ,50Hz±1Hz(60Hz) | |
DC withstand voltage testing | Output voltage adjustable and indication range 0-32kV, output current indication range 0-20A | |
Safety | Over-voltage, Over-current, Overheating protection. Automatic discharge after operation |
|
Protection rating | Not lower than IP54 | |
Total weight | Not more than 30kg | |
II,TDR cable fault locator XHGG502A2 | ||
Test method | Low voltage pulse, Impulse current(high voltage flashover) | |
Sampling rate | 80MHz | |
Pulse output | Unipolar | |
Pulse Amplitude | 100V±15% | |
Pulse width | 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS | |
Measurement scope | ≥65km | |
Measurement range | 300m/1km/5km/25km/65km | |
Minimum resolution | 0.1m | |
Measurement error | ≤±(0.5%×L+1m),L is cable length | |
Signal gain | 0…100%,adjustable | |
Propagation speed | 10…999.9m/µs | |
Output Impedance | Automatic match | |
Trigger | Automatic continute |
|
Working conditions | temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg | |
III,Cable fault pinpointer XHDD503C | ||
Fixed-point mode | Standard mode, enhanced mode, noise reduction mode, custom mode (ms, waveform) | |
Fixed point method | Intelligent time difference method, electromagnetic inspection method, acoustic measurement method | |
Positioning accuracy | Fixed point: 0.1m, Path: 0.1m | |
Display | TFT ultra-bright 5-inch, 800×480 true color | |
language | Graphical language is more intuitive | |
Gain | 120dB, fully automatic adjustment, also can be adjusted manually | |
Frequency range | 100~1600Hz | |
Dynamic Range | 0~112dB(16 gears) | |
Synchronous trigger | Acoustic fully automatic synchronous trigger; magnetic field fully automatic synchronous trigger | |
Detection range | 0.00~99.99ms,75mV~75V | |
Probe | Automatic mute, fully digital metal intelligent probe | |
Headphone | 600Ω military-grade strong noise reduction and anti-interference technology | |
Working power | 4*18650 Standard lithium battery | |
Working hours | More than 8 hours | |
Ambient temperature | -25~65ºC; relative humidity: ≤90% | |
Weight | Host 0.6kg; Sensor 1.4kg | |
Waterproof grade | IP65 | |
IV,Cable path comprehensive tester XHGX507C | ||
Receiver | ||
Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding (optional function) | |
Power | 8.4V large capacity rechargeable lithium battery | |
Input method | Built-in receiving coil, flexible caliper, A-frame (optional function) |
Sampling frequency | 80MHz |
Low voltage pulse amplitude | 100V±15% |
Ranging range | ≥65km |
Test range | 300m/1km/5km/25km/65km |
Pulse width | 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS |
Minimum resolution | 0.1m |
Test blind area | ≤20m |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
Power supply mode | charging AC110V~240V, 50Hz/60Hz |
Volume and weight | L358mm×W284mm×H168mm-4.7kg |
Working conditions | Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg |
1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
2 | Channel gain | 8 levels adjustable. |
3 | Magnetic channel gain | 8 levels adjustable. |
4 | Output gain | 16 levels (0~112db) |
5 | Output impedance | 350Ω |
6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
7 | Path identification accuracy | less than 0.5m. |
8 | Power supply | 4*18650 standard lithium batteries. |
9 | Standby time | more than 8 hours. |
10 | Volume | 428L×350W×230H |
11 | Screen pixels | 854-480 |
12 | Brightness | 800nit |
13 | Transmission speed unit | 0-100ms |
14 | Accuracy | 1ms |
15 | Sound bandwidth | 100-1.6khz |
16 | Magnetic coil bandwidth | 100-20kHZ |
17 | Both sound and magnetism are | greater than 75db |
18 | Weight | 6.5kg. |
19 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault finding (optional function) |
Power | 8.4V large capacity rechargeable lithium battery |
Input method | Built-in receiving coil, flexible caliper, A-frame (optional function) |
Receiving frequency | Active detection frequency: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz Power frequency passive detection frequency: 50Hz, 60Hz, 250Hz RF passive detection frequency band: center frequency is divided into 32.7kHz, 65.6kHz, 81.9kHz, 197kHz |
Pipeline detection mode | Broad peak method, narrow peak method, valley method |
Pipeline detection Detection range |
Direct connection method: Generally, the cable length can reach 0~20 km, which is mainly determined by the ground resistance, cable resistance and cable buried depth Coupling method: Generally, the cable length can reach 0~10 km, which is mainly determined by the ground resistance, cable resistance and cable buried depth Induction method: Applicable to cables buried less than 2m deep |
Depth and Current | Real-time display of cable depth and current value |
Pipeline measurement depth | 0-20m |
Depth Accuracy | Plane position precision: Center axis position of target cable or pipeline: ±5% (buried depth 0-3m) -10% (buried depth 3m-20m) |
True or False Tips | Eliminate interference from adjacent cables. When measuring adjacent cables, the measurement of adjacent cables can be distinguished based on the different signal strengths and measured current phases fed back by the adjacent cables. In the process of tracing the cables, observe the phase dial and pointer pointing to distinguish the measured cable from the adjacent cables. |
Sound Instructions | FM tone that varies with signal strength |
Anti-interference display | Green: No interference Green: Good (results can be trusted) Red: Severe interference (results cannot be trusted) |
Anti-interference ability | The extremely narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of nearby running cables and pipelines. |
Interference distance | When using the coupling method and the induction method, the transmitter will generate interference within a short distance. The interference distance is related to the transmission power and frequency. The greater the power and the higher the frequency, the stronger the interference. The minimum distance at which the receiver is not interfered by the transmitter often needs to be determined by experiment: Pipeline detection: 5m away for the coupling method and 20m away for the induction method can be confirmed as no interference Cable identification: 2~5m away for the coupling method can be confirmed as no interference |
Cable identification | Identification method: Intelligent identification by flexible clamps; Number of cables that can be calibrated: 1 to 20; Calibration value: The current percentage of the receiving signal and the transmitting signal is between 75% and 135% of the calibration value, which is one of the conditions for successful identification; Directionality: The transmitting clamp, the receiving clamp and the loading signal must be in the same direction, which is one of the conditions for successful identification. |
Cable identification Detection range |
Direct connection method: can identify signals with a loop resistance of 0Ω to 8kΩ (usually can reach a cable length of 0 to 20 kilometers, mainly determined by the ground resistance and cable resistance) Coupling method: can identify signals with a loop resistance of 0Ω to 1kΩ; (usually can reach a cable length of 0 to 6 kilometers, mainly determined by the ground resistance and cable resistance) |
Display | 4.3-inch LCD color screen (high brightness screen), visible in sunlight |
Touch | Yes, capacitive touch |
size | Approx. 350mm(L)×155mm(W)×700mm(H) |
Weight | Approx. 2kg |
Connection interface | Type-C USB port, aviation socket |
Coil inner diameter | φ200mm (larger diameter can be customized as needed) |
Working temperature and humidity | -10ºC~40ºC; below 80%Rh |
Storage temperature and humidity | -10ºC~50ºC; ≤95%RH, no condensation |
Pressure resistance | AC2000V/rms (before the front and rear ends of the shell) |
Suitable for safety regulations | IEC61010-1 CAT 600V, IEC61010-031, IEC61326, pollution degree 2 |
Transmitter | 1 |
Receiver | 1 |
Toolkit | 1 |
Transmitting current clamp | 1 |
Receiver Flexible Current Clamp | 1 |
Direct-connect test clamp | 1 |
Double-ended alligator clip test lead | 1 |
Ground pin | 1 |
Receiver Charger | 1 |
Transmitter Charger | 1 |
A frame | 1 |
Impact high voltage | 0~32kV |
High voltage partial pressure | 2.5 level |
Built-in capacitor | 2μF |
Discharge power | 0-1024J |
Output voltage polarity | negative polarity |
Impact power | 250W@peak |
Working mode | Selectable or adjustable impulse rate and Single shot |
Minimum Output current in DC mode | 7.5mA at 32kV |
Length of test cable | The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long. |
Over temperature protection | 65ºC |
Over current protection | 8mA (more than 3 seconds) |
Volume(mm) | 540L×300W×450H |
Weight | not more than 25kg |
Power supply | AC220V±15%, 50Hz±2Hz(60Hz) |
Ambient temperature | -20~+60ºC |
Cable length | High voltage output cable - 2 meters, ground wires - 2.5 meters, power cable - 1.8 meters. |