Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

Product Details
Customization: Available
After-sales Service: Warranty Certificate
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
  • Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
XHGG502+XHDD503D+XHHV535-2L
Power
Electricity
Certification
CE, ISO
Customized
Customized
Transport Package
Wooden Case Filled with Foam
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
100 Pieces /Year

Product Description

 

Product Description

XZH TEST portable cable fault locator set is designed for 35kV and below underground cable fault location. 
Consist with a cable fault pre-locator(XHGG502), a cable fault pinpointer(XHDD503D), a max impact voltage 35kV high voltage surge generator(XHHV535-2L)
 

★Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), ICE(impulse current test method), multiple impulse(ARC-multi-short)arc reflection method.

 

★Cable fault pinpoint location: XHDD503D uses acoustic-magnetic synchronization method, digital display waveforms of sound and magnetic, judge cable fault point by time difference and earphone, make detection more easier.
 

 

 

 The portable cable fault location system is configured with the removable ARC cable fault locator with ultra-high brightness, large LCD screen 12.1" display with touch control, making the process of fault pre-location quick, easy and efficient.

 

High voltage 1225 J surge generator is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 35 kV.

 

It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults.

XHDD503D Digital cable fault pinpointer
XHGG502 ARC/ARM cable fault pre locator
XHHV535-2L High voltage pulse generator



---------------------------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

503D has a powerful background noise reduction function, especially suitable for complex environment cable fault accurate fixed point, acoustic magnetic synchronous detection, acoustic and magnetic wave time difference directly displayed on the screen, making fault judgment more simple. 

503D also has auxiliary path detection function, when the fault point, the screen shows the probe on the left or right side of the cable, so that the operator does not deviate from the cable path.


Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
Portable waterproof carrying case with no less than IP54 protection grade.

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System


----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Accurately and quickly detect the main insulation failure of power cables with voltage levels of 35KV and below; calibrate the cable length; roughly test cable fault distance

 
  • Pre-locating cable faults with the reflectometer XHGG502 based on the
low-voltage pulse reflection method (TDR),
high voltage flashover 
method (ie. ICE, DECAY),
arc reflection pulse reflection method (ARC 
single shot and ARC multi-shot) 



Cable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(flashover) method (DECAY), arc reflection method(single-shot/ multi-shot).

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System


There are three test mode of XHGG502, low voltage pulse, high voltage flashover, ARC multi-shot.
--------------------------------------------------------------------------------------------------------------------------------------------------------


The below picture shows cable fault distance measured by using ARC multi-shot test mode of XHGG502.
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

--------------------------------------------------------------------------------------------------------------------------------------------------------

The below picture shows cable fault distance measured by using high voltage flashover test mode of XHGG502

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

--------------------------------------------------------------------------------------------------------------------------------------------------------

The below picture shows cable length or cable open circuit fault distance measured by using low voltage pulse test mode of XHGG502. When using the low voltage pulse method, it is not necessary to connect the high voltage pulse generator. Other test methods must be used in conjunction with a high-voltage pulse generator.

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System


----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

                          New version                                              Old version

 

The XHHV535-2L high-voltage pulse generator is mainly used for shock discharge during cable fault test.It can also be used for DC withstand voltage test of other electrical equipment.

This device integrates DC high voltage source, energy storage capacitor, discharge ball gap, etc. This device completely replaces the traditional hundreds of kilograms of test transformers, operation boxes and pulse energy storage capacitors (generally a set of 5kVA transformers are more than 60 kilograms, control The box is more than 30 kg, and the pulse energy storage capacitor is more than 20 kg).

The power supply adopts high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, which makes the whole machine simple in structure and ultra-light in weight. In order to retain people's habit of using transformers and operation boxes to generate DC high voltage, this pulse generator adopts humanized design and operation mode, which is safe and reliable. Really achieve the effect of not being damaged by impact, and the short circuit of high voltage to ground can also work normally. It is currently the lightest and most user-friendly portable DC shock high-voltage equipment. It is an ideal product for power cable fault detection.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Product features

 With over-current, over-voltage, overheating automatic protection function;
★ With DC withstand voltage, impact discharge function;
 The high-voltage pulse output is uniform and controllable;
 Super short-circuit protection function, which can make the high-voltage output directly short-circuit to the ground;
 It has dual 2.5-level pointer meters for current and voltage display, which is intuitive and clear, and it is clear at a glance whether the fault point is fully discharged, and the discharge process is reflected in real time;
 High-voltage side voltage measurement, real-time and accurate;
 With zero start protection and potentiometer zero output function, it is safe and reliable;
 Unique high-voltage measurement design, in the stop state, the voltmeter can indicate the capacitor voltage in real time;
 The discharge time can be arbitrarily set within the appropriate interval;

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Technical data
Impulse voltage 0-35kV
High voltage partial pressure 2.5 class
Built-in capacitor 2μF
Discharge power 0~1225J
Output voltage polarity negative polarity
Over-current protection 8mA (more than 3 seconds)
Impact power 400W
Over temperature protection 85ºC
Volume(mm) 540L×300W×450H
Weight no more than 25kg
Working power supply AC 220V±10%/50Hz±2Hz
Ambient temperature -20~+60ºC

--------------------------------------------------------------------------------------------------
Panel introduction
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
1. Safety ground: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified or electric shock to personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to prevent high-voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled under the high-voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage output is in the zero position. When the light is on, the start button is valid. If the start button light is not on after turning on the power switch, turn the voltage adjustment knob counterclockwise until the light is on. When the button light is on, press this button to start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, the high-voltage light goes out, and the internal discharge ball stops working. When the stop key is on, it means there is high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current protection function has started; when it is popped up, it means that the instrument has triggered the over-current protection.
8. Voltage adjustment: After turning on the device, you must first turn the knob counterclockwise to the end, press the start button, and then adjust clockwise to increase the output high voltage from small to large, and adjust counterclockwise to reduce the output high voltage from large to small.
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns off the system power.
10.The fuse holder: the place where the fuse of the AC 220V power supply system is installed.
11. Power socket: the working power supply of the instrument, AC 220V connection port.
12. Time setting: Set the discharge time interval.
13. Ammeter: indication of the current on the high voltage side.
14. Voltmeter: high voltage output voltage indicating kV meter.
15. High-voltage output (EMP): When impacting discharge, connect the high-voltage output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage output line.
--------------------------------------------------------------------------------------------------
Packing list
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System
Application- underground cable fault location
Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System


We are a professional manufacturer of cable fault detection equipment, we can customize the special technical solution for you.
Welcome you contact us for more information.

 
 
 

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System  Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

Portable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location SystemPortable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location SystemPortable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location SystemPortable Underground Cable Locator Distance to Fault Tester Electric 10kv Cable Fault Location System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier