XZH Portable low and medium voltage cable fault locating system
XHGG502 | Cable fault pre locator |
XHDD503C | Cable fault pinpointer |
XHGX507 | Cable route tracer/Cable pipe locator |
XHHV535-4TS | High voltage surge generator |
XHGG502
Main features
• The reflected signal sent by the pulse coupler is automatically displayed, and the full-length waveform of the cable open circuit is displayed at the same time.
• Automatic calculation and display of fault distance;
• It has the function of storing massive test waveforms: the waveforms obtained from the field test can be conveniently stored in the instrument according to the specified order, and can be recalled and observed at any time;
• With standard printer USB interface;
• Simple operation and high reliability. Has a very high cost performance;
• Built-in polymer lithium battery power supply, which can test cable open circuit and low resistance short circuit fault in no power supply environment.
The test working modes of XHGG502 ARC cable fault pre locator include low voltage pulse method, high voltage flashover method, and multiple pulse method. Here focus on the multiple pulse method that is different from other devices.
The below picture shows low voltage pulse test mode of XHGG502, test cable length, cable open circuit fault distance, short circuit fault distance.
The below picture shows high voltage flashover test mode of XHGG502, measured cable fault distance.
Sampling frequency | 400MHz |
Minimum resolution | 0.5m (100m/us) |
Low voltage pulse width | 0.2uS/2uS/4uS |
Test blind zone | ≤20m |
Ranging range | ≥68km |
Measurement error | ≤±(0.5%×L+1m), L is the cable length |
There are three test cable lengths | <1km (short distance); <3km (medium distance); >3km (long distance), (low-voltage pulse test amplitude: 400Vpp) |
Pulse coupler withstand voltage | DC 35kV |
Measuring pulse | Low voltage pulse 300V±10% |
Output impedance | 350 Ohm |
Input signal gain | ±64dB |
Power consumption | 120VA |
propagation speed factor | 10-300m/μs |
Working conditions | temperature -25ºC~+65ºC, relative humidity 85%, atmospheric pressure 750±30mmHg |
Volume and weight | Cable fault tester 430×380×220mm-10kg; Pulse coupler 430×380×220mm-10kg |
XHDD503C
The cable fault location instrument uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.
This cable fault pinpointer is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Fault. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites".
1 | Filter parameters | All-pass: 100Hz~1600Hz. Low pass: 100Hz~300Hz. Qualcomm: 160Hz~1600Hz. Bandpass: 200Hz~600Hz. |
2 | Channel gain | 8 levels adjustable. |
3 | Magnetic channel gain | 8 levels adjustable. |
4 | Output gain | 16 levels (0~112db) |
5 | Output impedance | 350Ω |
6 | Acoustomagnetic positioning accuracy | less than 0.2m. |
7 | Path identification accuracy | less than 0.5m. |
8 | Power supply | 4*18650 standard lithium batteries. |
9 | Standby time | more than 8 hours. |
10 | Volume | 428L×350W×230H |
11 | Screen pixels | 854-480 |
12 | Brightness | 800nit |
13 | Transmission speed unit | 0-100ms |
14 | Accuracy | 1ms |
15 | Sound bandwidth | 100-1.6khz |
16 | Magnetic coil bandwidth | 100-20kHZ |
17 | Both sound and magnetism are | greater than 75db |
18 | Weight | 6.5kg. |
19 | Ambient temperature | -25~65ºC; Relative humidity: ≤90%. |
XHHV535-4TS
The XHHV535-4TS high voltage pulse generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.
High voltage surge generator XHHV535-4TS |
Surge voltage levels and adjustment ranges |
Level 1 : 0-8KV Level 2: 0-16KV Level 3: 0-32KV |
Surge voltage levels switch | Manual | |
Voltage adjustment type | Continuous | |
Indication | High-voltage side voltage metering, indication of output voltage and current in real time | |
Surge energy at each level | Up to 2048J | |
Operating mode | Single trigger, cycle, DC | |
Operating modes switch | Manual | |
Impact time | about 7 seconds for automatic impact, arbitrary control time for manual impact | |
Impact power | 2KVA | |
Continuous output current | 60mA | |
Built-in capacitor | 4μF/32kV, 16μF/16kV, 64μF/8kV three-speed adjustment | |
Safe operation | With zero start protection function, safe and reliable | |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | |
Working power | AC 220V±10% 50Hz±2Hz (other voltage and frequency can be customized) | |
DC withstand voltage testing | Output voltage adjustment and indication range 0-32KV, Output current indication range 0-20A |
|
Burn current | Fault conditioning (burning) with current up to 60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV. |
|
Connecting cable | High voltage output cable: 5m, Protective earthing cable:5m,power cord 2.5m. Cables can be customized according to customer requirements. | |
Safety | Over-voltage, Over-current, Overheating protection. Automatic discharge after operation. |
|
Protection rating | Not lower than IP54 | |
Working power | AC 220V±15%, 50Hz±2Hz | |
Dimensions(mm) | 534L×444W×805H | |
Total weight | About 120kg |