Portable Cable Fault Tester Set for Medium and Low Voltage

Product Details
Customization: Available
After-sales Service: Warranty
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2022-08-12
  • Portable Cable Fault Tester Set for Medium and Low Voltage
  • Portable Cable Fault Tester Set for Medium and Low Voltage
  • Portable Cable Fault Tester Set for Medium and Low Voltage
  • Portable Cable Fault Tester Set for Medium and Low Voltage
  • Portable Cable Fault Tester Set for Medium and Low Voltage
  • Portable Cable Fault Tester Set for Medium and Low Voltage
Find Similar Products
  • Overview
  • XHGG502A2
  • XHDD503B
  • XHGX507
  • XHHV515-8L
Overview

Basic Info.

Model NO.
502A2+503B+507+515-8L
Power
Electricity
Certification
CE, ISO
Customized
Customized
Color
Black
Transport Package
Wooden Box with Foam Inside
Trademark
XZH TEST
Origin
China Xi′an
Production Capacity
1000pieces/Year

Product Description

XHGG502A2

 

                                  

Portable Cable Fault Tester Set for Medium and Low Voltage
Description

The cable fault tester adopts an industrial-grade 10.1-inch touch-integrated computer, a simple operating software interface, industrial-grade integrated circuits and devices, and a built-in large-capacity lithium-ion battery, which is stable, reliable, and easy to use.

This cable fault tester is a special instrument for measuring and analyzing the status and fault distance of power cables. This cable fault tester uses a combination of modern electronic technology and computer technology to achieve signal filtering, acquisition, data processing, graphic display, and graphic analysis. Cable speed measurement, cable length test, cable fault distance test.

This cable fault tester is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Network failure. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites", "DL/T 849.1-2019 General technical conditions for special testers for power equipment Part 1: Cable fault flash tester", "JJF1042-2020" "Calibration Specifications for Cable Fault Testers" standard requirements.
Work mode: TDR(low voltage pulse), High voltage flashover( ICE(Impulse current)/Decay)

Features
• 10.1-inch full-color TFT touch display;
• Embedded system, safe, stable and simple display and operation mode;
• With the function of testing cable wave speed, cable length and fault distance;
• Fully automatic continuous sampling, waveform capture at all times, timely and accurate.
• Equipped with automatic test range setting, automatic waveform analysis and display of test distance.
• Full English menu, two operation methods of touch and coded buttons, simple, fast and reliable.
• Equipped with testing technology of low-voltage pulse method, high-voltage flashover method, the waveform display is smooth and easy to interpret.
• The instrument has powerful data processing capabilities, making it convenient for users to manage and archive waveform files.
• Has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument in the order specified by Chinese naming for recall and observation at any time; it can store more than 8,000 records of low-voltage pulses and high-voltage flashover waveforms, and multiple pulses More than 250 waveform records can be recorded, and waveform files can be imported into computer software for management and analysis using USB communication.
• Ultra-high brightness, LED backlight brightness reaches 280nit, resolution 1024*600, convenient for environments exposed to direct sunlight in operation.

Technical specification
 

Sampling frequency 80MHz
Low voltage pulse amplitude 100V±15%
Ranging range 65km
Test range  300m/1km/5km/25km/65km
Pulse width 0.125uS/0.50uS/2.50uS/7.25uS/10.0uS
Minimum resolution 0.1m
Test blind area 20m
Measurement error  ≤±(0.5%×L+1m), L is the cable length
Power supply mode charging AC110V~240V, 50Hz/60Hz
Volume and weight L358mm×W284mm×H168mm-4.7kg
Working conditions Temperature -20ºC~+65ºC, relative humidity 90%, atmospheric pressure 750±30mmHg


Packing list

Portable Cable Fault Tester Set for Medium and Low Voltage

 
XHDD503B

 

Portable Cable Fault Tester Set for Medium and Low Voltage

Introduction
Cable fault locator XHDD503B uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.

Technical indicators

Acoustic-magnetic synchronous fixed-point function
 
Acoustic-magnetic synchronous fixed-point function
 
Sound channel a) Bandwidth
All pass: 100Hz~1500Hz.
Low pass: 100Hz~400Hz.
Qualcomm: 150Hz~1500Hz.
Band pass: 200Hz~600Hz.
b) Maximum signal gain: >=100dB.
c) Fixed-point accuracy: 0.1m.
 
Magnetic field channel Maximum signal gain: >=100db
 
Acoustomagnetic transit time positioning mode: waveform display, acoustic and magnetic transit time display.
Signal gain: adjustable from 1 to 8 levels.
Magnetic field channel: adjustable from 1 to 8 levels
Sound signal strength bar graph indicates, and the sound trigger threshold (0 to 99 levels) is adjustable.
The electromagnetic signal strength is indicated by a bar graph, the magnetic field trigger threshold (0 to 99 levels) is adjustable, and it has a magnetic field trigger prompt function.
Electromagnetic signal strength bar graph indication, adjustable magnetic field trigger threshold, with magnetic field trigger prompt function.
 
Acoustic-magnetic time difference positioning mode: waveform display, the maximum acoustic-magnetic time difference is 80ms, which can be automatically calculated and manually analyzed; it can record the last time acoustic-magnetic time difference.
 
Power supply:
 
a) Battery: built-in lithium-ion battery pack, voltage 8.4V, capacity 2.4Ah
b) Use time: continuous use time > 8 hours;
c) Charger: input AC220V±10%, 50Hz; nominal output 8.4V, 1A
d) Charging time: <3 hours.
 
Display mode: 5-inch color LCD, 854*480 resolution, with touch function.
Operating environment temperature: -20°C-65°C, humidity ≤90% RH, altitude <4500m.
 
Packing list
Portable Cable Fault Tester Set for Medium and Low Voltage
 
  1. Operation panel introduction

Portable Cable Fault Tester Set for Medium and Low Voltage
1 Adjustment: Press the adjustment button to enter the adjustment interface, and rotate the adjustment button to set the adjustment parameters;

2 Power supply: Turn on and off the power supply of the system. When turning on the system, you need to press and hold the power button for 3 to 4 seconds until you hear a long "beep" sound, then you can lift the button; when turning off, you need to press and hold the power button for 3 to 4 seconds;

3 Display: 5-inch touch display.
Portable Cable Fault Tester Set for Medium and Low Voltage1 Sensor: Probe sensor connection port;
2 Charging: charger connection port;
3 Dedicated headphone jack.

XHGX507

 


Portable Cable Fault Tester Set for Medium and Low VoltageDescription
XHGX507 underground cable pipe locator is mainly used for cable fault location, cable identification, cable path and depth measurement. It can complete tasks that could only be accomplished by a few sets of instruments in the past.

Features
The large-screen LCD displays the signal strength, and the bar, arrows and voice prompts make it easy for the operator to judge the underground position of the cable and the fault point. One person can do it all.

All-digital design, clear large-screen LCD graphic display and reliable positioning

Portable and lightweight, easy to carry

Built-in rechargeable battery

Built-in ohmmeter to measure cable loop resistance

Can be used to detect insulation faults up to 2MΩ to ground

With backlight function to adapt to night operation

Built-in ohmmeter to measure cable loop resistance

Display cable depth and current

Main components

This cable pipe locator is mainly composed of transmitter and receiver, with accessories of two clamps, one A-frame and necessary connection wires.
Portable Cable Fault Tester Set for Medium and Low VoltageTechnical Parameters

Transmitter

Working frequency low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz)
 
Working mode direct connection method, coupling method (caliper method), induction method
 
Matching load 5 ohms-3000 ohms
Impedance display 5 digits
Overheating and over current automatic protection
Power output low gear, middle gear, high gear
Receiver
Working frequency low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz),  Passive frequency 50Hz
 
Antenna mode valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame)
 
Current indication display the effective current value of the cable under test (unit: mA)
 
Working temperature -10ºC+55ºC
Power indicator graphic display
Battery life continuous work> 8 hours: intermittent work> 16 hours
 
Signal strength indication ladder diagram, digital range 0-999
 
Gain control manual adjustment, dynamic range of 100dB
Detection depth the maximum detection depth is around 10 meters
 
Maximum detection distance The cable with good insulation can be up to 15km in the direct connection method
 
Depth measurement press the depth key to display three digits, the maximum depth can be measured up to 10 meters
 
Accuracy Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m
 

More photos
Portable Cable Fault Tester Set for Medium and Low VoltagePortable Cable Fault Tester Set for Medium and Low Voltage

XHHV515-8L

Portable Cable Fault Tester Set for Medium and Low VoltageDescription
The XHHV515-8L High voltage pulse generator is a tie-rod portable integrated device, which is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry. 
Panel introduction
Portable Cable Fault Tester Set for Medium and Low VoltagePanel function description
1. Safety ground: The ground of the instrument shell must be reliably connected to the
ground in order to prevent the instrument shell from being electrified or electric shock to
personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to
prevent high-voltage leakage and discharge. Poor contact may cause failure to boost
the voltage, high voltage breakdown of the internal components of the instrument, and
safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a
high voltage and must be grounded reliably. It is used for sampling when the waveform
is sampled under the high-voltage flashover state of the cable fault tester. (WithoutHigh voltage surge generator
high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: Press this button to make contact with the ball gap, and discharge
manually. (The duration of each key press cannot exceed 1s).
5. High voltage start button: When the start button light is on, it means that the voltage
output is in the zero position. When the light is on, the start button is valid. If the start
button light is not on after turning on the power switch, turn the voltage adjustment knob
counterclockwise until the light is on. When the button light is on, press this button to
start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs,
press this button to cut off the high-voltage output, the high-voltage light goes out, and
the internal discharge ball stops working. When the stop key is on, it means there is
high voltage output, and when it is off, it means there is no high voltage output.
7. Over-current protection switch: When pressed, it means that the over-current
protection function has started; when it is popped up, it means that the instrument has
triggered the over-current protection.
8. Voltage adjustment: After turning on the device, you must first turn the knob
counterclockwise to the end, press the start button, and then adjust clockwise to
increase the output high voltage from small to large, and adjust counterclockwise to
reduce the output high voltage from large to small.
9. Power switch: "I gear" turns on the AC 220V power supply switch, and "0 gear" turns
off the system power.
10. The fuse holder: the place where the fuse of the AC 220V power supply system is
installed.
11. Power socket: the working power supply of the instrument, AC 220V connection
port.
12. Time setting: Set the discharge time interval.
13. Ammeter: indication of the current on the high voltage side.
14. Voltmeter: high voltage output voltage indicating kV meter.
15. High-voltage output (EMP): When impacting discharge, connect the high-voltage
output line.
16. High voltage output (DC): When DC withstand voltage, connect the high voltage
output line

Technical parameters
Impact high voltage 0~15kV
High voltage partial pressure 2.5 level
Built-in capacitor 8μF
Discharge power 0-900J
Output voltage polarity negative polarity
Impact power 250W @peak
Working mode Selectable or adjustable impulse rate and Single shot
Minimum Output current in DC mode  16mA at 15kV
Length of test cable The high-voltage output line of the pull-rod type high-voltage pulse generator is 2 meters long, the ground line is 3 meters long, and the power line is 1.8 meters long.
Over temperature protection 65ºC
Over current protection 8mA (more than 3 seconds)
Volume(mm) 540L×300W×450H
Weight not more than 25kg
Power supply AC220V±15%, 50Hz±2Hz(60Hz) 
Ambient temperature -20~+60ºC

Packing List
Portable Cable Fault Tester Set for Medium and Low Voltage



More photos
Portable Cable Fault Tester Set for Medium and Low VoltagePortable Cable Fault Tester Set for Medium and Low Voltage
Welcome you contact us for more information~

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier